• Title/Summary/Keyword: implementation feasibility

Search Result 595, Processing Time 0.028 seconds

Synthesis and Implementation of a Multi-Port DC/DC Converter for Hybrid Electric Vehicles

  • Santhosh, T. K.;Natarajan, K.;Govindaraju, C.
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1178-1189
    • /
    • 2015
  • A non-isolated Multiple Input Converter (MIC) with an input port, two storage ports and a load port is proposed. The synthesis of the proposed four port converter with its switch realization is presented. A steady state analysis of each operating mode with a small-signal model is derived, and a stability analysis is done. A mode selection controller is proposed to automatically choose a specific operating mode based on the voltage levels of the different source and storage units. In addition, a voltage control loop is used to regulate the output voltage. A 200W prototype is built with a TMS320F28027 DSP controller to test the feasibility of the operating modes. Simulation and experimental results show the ability of the proposed converter to handle multiple inputs either individually or simultaneously.

Development of Position Indicator for System-Integrated Reactor SMART (일체형원자로 SMART의 제어봉 위치지시기 개발)

  • Yu, Je-Yong;Kim, Ji-Ho;Huh, Hyung;Kim, Jong-In;Chang, Moon-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.921-926
    • /
    • 2001
  • The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. In this study, a thorough investigation on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. A design of the control rod position indication system using reed switch for the CEDM on the system-integrated reactor SMART was developed based on the position indicator technology identified through the investigation. The feasibility of the design was evaluated by test of manufactured control rod position indicator using reed switch for SMART.

  • PDF

Design and Implementation of a SDR-based Digital Filter for CDMA Systems

  • Yu, Bong-Guk;Bang, Young-Jo;Kim, Dae-Ho;Lee, Kyu-Tae;Ra, Sung-Woong
    • Journal of Ubiquitous Convergence Technology
    • /
    • v.2 no.2
    • /
    • pp.59-66
    • /
    • 2008
  • In this study, Software Defined Radio (SDR) technology-based digital filterbank architecture applicable to a multiple-channel processing system such as a wireless mobile communication system using Code Division Multiple Access (CDMA) technology is proposed. The technique includes a micro-processor to redesign Finite Impulse Response (FIR) filter coefficients according to specific system information and to download the filter coefficients to one digital Band Pass Filter (BPF) to reconfigure another system. The feasibility of the algorithm is verified by computer simulation and by implementing a multiple-channel signal generator that is reconfigurable to other system profiles, including those of a Wideband Code Division Multiple Access (WCDMA) system and a CDMA system.

  • PDF

New Controller for Power Factor and Harmonics Compensation of Single-Phase PWM Converter without AC Voltage Sensor (단상 PWM 컨버터의 역률 및 고조파 보상을 위한 교류전압 검출기가 없는 새로운 제어기)

  • Jon, Y.S.;Baek, S.T.;Kim, H.J.;Han, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.161-165
    • /
    • 2003
  • In this paper, A new controller for power factor and harmonics compensation of a single-phase PWM converter is described. The proposed controller requires only the dc voltage sensor and the at current sensor to compensate the power factor and harmonics. Detail simulation model with EMTBC (Electro-Magnetic Transient program for DC transmission) including power circuit and controller was developed to verify the operation of proposed controller. The application feasibility of the proposed controller was verified through experimental works with a prototype. The proposed controller has a simple structure in the point of hardware implementation, and shows excellent performance in normal operation as well as in sudden load change.

  • PDF

Dynamic Characteristic Analysis of SSSC Based on Multi-bridge PAM Inverter

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.539-545
    • /
    • 2001
  • This paper proposes a static synchronous series compensator based on multi-bridge inverter. The proposed system consists of 6 H-bridge modules per phase, which generate 13 pulses for each half period of power frequency. The dynamic characteristic was analyzed by simulations with EMTP code, assuming that it is inserted in the 154-kV transmission line of one-machine-infinite-bus power system. The feasibility of hardware implementation was verified through experimental works using a scaled model. The proposed system does not require a coupling transformer for voltage injection, and has flexibility in expanding the operation voltage by increasing the number of H-bridge modules.

  • PDF

Dynamic Characteristic Analysis of SSSC based on Multi-bridge PWM Inverter

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.718-722
    • /
    • 2001
  • This paper proposes an SSSC based on multi-bridge inverters in PWM scheme. The proposed system consists of 6 H-bridge inverter modules per phase. The dynamic characteristic of proposed system was analyzed by simulation with EMTP codes, assuming that the SSSC is inserted in the 154-kV transmission line of one-machine-infinite-bus power system. The feasibility of hardware implementation was verified through experimental works with a scaled-model. The proposed system can be directly inserted in the transmission line without coupling transformers, and has flexibility in expanding the operation voltage by increasing the number of H-bridges.

  • PDF

Mini-Slot-Based Transmission Scheme for Local Customer Internetworking in PONs

  • Kim, Jae-Gwan;Chae, Chang-Joon;Kang, Min-Ho
    • ETRI Journal
    • /
    • v.30 no.2
    • /
    • pp.282-289
    • /
    • 2008
  • We propose a new mini-slot transmission scheme for a passive optical network (PON) in which each customer can be switched either to access mode or to internetworking mode dynamically. In this paper, we present the system implementation (called LAN-PON) as well as the performance of the proposed transmission scheme to illustrate its feasibility and benefits. A mini-slot scheme can rapidly reduce the queuing delay, which increases due to the flooding of the deflected packets in a deflection scheme. We evaluate the impact of mode switching time on the bandwidth gain (throughput) and delay of local area network (LAN) traffic in the LAN-PON with a mini-slot scheme. We also analyze a theoretical delay model of the proposed scheme. The simulation results demonstrate that switching time has an impact on LAN performance, and the average packet delay of the proposed scheme is significantly improved compared to that of the deflection scheme.

  • PDF

Ultrasonic flushing 기법에 의한 유류오염토양의 복원에 관한 실험연구

  • Jeong, Ha-Ik;Oh, In-Gyu;Kim, Sang-Geun;Lee, Yong-Su;Yoo, Jun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.13-17
    • /
    • 2002
  • Ultrasonic waves have several mechanical, chemical, and biological effects on a saturated soil medium. Their mechanical effects, popularly known as cavitation. Cavitation is the rapid and repeated formation, and resulting implosion, of imcrobubbles in a liquid, resulting in the propagation of microscopic shock waves. In a soil-liquid system, their mechanical effects generate high differntial fluid-particle velocities and microscopic shock waves. The velocity perturbations are capable of dislodging oil in the system by overcoming the forces binding oil to sand particles. In this study, a series of laboratory experiments involving the simple flushing and ultrasonic flushing were carried out. An increase in permeability and oil removal rate were observed in ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of ultrasonics.

  • PDF

초음파동전기세척 복합기법에 의한 오염부지 복원기술

  • 정하익;김상근;송봉준;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.183-185
    • /
    • 2004
  • In this study, the combined electrokinetic and ultrasonic remediation technique, ultrasonically enhanced electrokinetic technique, was studied for the removal of heavy metal and organic substance in contaminated soils. The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique has been to remove mainly organic substance in contaminated soil. The laboratory soil flushing tests combined electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of these both techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

  • PDF

Controllable Harmonic Generating Method for Harmonic Impedance Measurement of Traction Power Supply Systems Based on Phase Shifted PWM

  • Liu, Qiujiang;Wu, Mingli;Li, Jing;Zhang, Junqi
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1140-1153
    • /
    • 2018
  • The harmonic impedance characteristic of a traction power supply system (TPSS) is necessary for taking actions to suppress the high-order harmonic resonances caused by AC electric locomotives. This paper proposes a controllable harmonic generating method (CHGM) for measuring the TPSS harmonic impedance by injecting harmonic disturbances of different frequencies and amplitudes into the TPSS. This method applies phase shifted pulse-width modulation (PSPWM) and ensures that the undesired sideband harmonics can be negligible while the desired harmonic is both controllable and adjustable. Multiple harmonics can be emitted at the same time. The implementation of the method is also presented. Simulations are carried out to validate the performance of the proposed method. Finally, experimental results on a 5 H-bridge converters platform verified the effectiveness and feasibility of the proposed method.