• Title/Summary/Keyword: implant restoration

Search Result 366, Processing Time 0.03 seconds

CLINICAL EVALUATION OF PROGNOSIS OF OSSEOINTEGRATED DENTAL IMPLANT IN TREATMENT OF MAXILLARY EDENTULOUS AREA (골유착 치과 임플란트를 이용한 상악 무치악부 치료의 예후에 관한 임상적 평가)

  • Shim, Won-Bo;Lee, Dong-Keun;Choi, Kyu-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.189-197
    • /
    • 1999
  • The use of osseointegrated implant has been reported that is an acceptable procedure for the restoration of totally or partially edentulous patient and that offers good predictability of long term success. It is difficult to get high success rate in edentulous maxillae with inadequate bony quality and quantity, and anatomic limitations such as pneumatic maxillary sinus and nasal floor. The various trials such as sinus lifting, bone grafting, guided bone regeneration, trabecular condensation with osteotome, and the use of wide-diameter implant have been introduced to solve these problems. This study was undertaken to assess the evaluation of clinical prognosis of the implant restorations with these various implantation techniques in the maxillary edentulous area. One hundred eight patients were treated with a total of 386 endosseous implants from March 1994 to January 1998 at Dept. of Dentistry, Korea Veterans Hospital in Seoul Korea. The various techniques for implantation in the edentulous maxillae were supplied to overcome the limitations of implant fixation. These techniques consist of sinus lifting, guided bone regeneration, onlay bone grafting, and osteotome trabecular condensation technique. The total success rate of implant restoration of this study was 93% in the maxillae. The success rate of implant restorations with conventional technique was 94.6%, with osteotome trabecular condensation technique was 94.1%, with guided bone regeneration technique was 93.3%, with bone grafting technique was 92.9%, with sinus lifting technique was 83.8%. The success rate on the maxillary anterior area was 95.2% and that on the posterior area was 91.9%. The failures were associated not only with surgical installation techniques but also bony quality and quantity, characteristics of implant, and stress distribution when in function.

  • PDF

Implant Breast Reconstruction Using Porcine Dermal Matrix ($Permacol^{(R)}$): A Comparative Study with Acellular Cadaveric Dermis ($AlloDerm^{(R)}$) (돼지진피조직(Porcine Dermal Matrix, $Permacol^{(R)}$)을 이용한 보형물 유방재건술: 무세포성 사체 진피 (Acellular Cadaveric Dermis, $AlloDerm^{(R)}$)와 비교 연구)

  • Jeong, Bo-Rham;Roh, Tai-Suk;Kim, Young-Seok;Hong, Jong-Won;Rah, Dong-Kyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.559-566
    • /
    • 2011
  • Purpose: The use of tissue expander/implant in breast reconstruction using tissue expander-implant is one of the most common surgical procedures. The use of AlloDerm as a sling to reestablish the lower pole of the pectoralis major muscle results a decrease in morbidity compared with more invasive procedures. However the use of AlloDerm is more expensive than other options. We decided to compare AlloDerm with Permacol, which has been safely used in human body reconstruction and is less costly than AlloDerm. Methods: After mastectomy, the inferolateral origin of the pectoralis major muscle was elevated. Either AlloDerm or Permacol was sutured to the chest wall at the level of the previously marked inframammary fold. The lower border of the pectoralis major muscle and the upper portion of the crescent-shaped piece of either AlloDerm or Permacol was sutured together using a tension free technique, and a tissue expander was subsequently inserted into the subpectoral-subAlloDerm (or Permacol) dual pocket. Results: AlloDerm was used in twenty-one patients (28 breasts) and Permacol was used in six patients (11 breasts) for tissue expander-implant breast reconstruction. During the mean follow-up period of 17 months (8~25 months). Two infections (7%) occurred in AlloDerm cases and four infections (36%) occurred in Permacol cases. Conclusion: This study is the first comparison of tissue expander/implant breast reconstruction using AlloDerm and Permacol. The use of Permacol resulted in more postoperative infection compared with the use of AlloDerm. This report is still limited with the small number of cases studied.

Esthetic implant restoration in the maxillary anterior missing area with palatal defect of the alveolar bone: a case report (구개부 치조골 결손을 보이는 상악 전치 상실부의 임플란트 심미보철수복: 증례보고)

  • Oh, Jae-Ho;Kang, Min-Gu;Lee, Jeong-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.291-298
    • /
    • 2017
  • It is challenging to produce esthetic implant restoration in the narrow anterior maxilla region where insufficient volume of alveolar bone could limit the angle and position of implant fixture, if preceding bone augmentation is not considered. Ideal angle and position of implant fixture placement should be established to reproduce harmonious emergence profile with marginal gingiva of implant prosthesis, bone augmentation considered to be preceded before implant placement occasionally. In this case, preceding bone augmentation has been operated before esthetic implant prosthesis in narrow anterior maxilla region. Preceded excessive bone augmentation in buccal area allowed proper angulation of implantation, which compensates unfavorable implant position. Provisional restorations were corrected during sufficient period to make harmonious level of marginal gingiva and interdental papilla. The definite restoration was fabricated using zirconia core based glass ceramic. Functionally and esthetically satisfactory results were obtained.

Full mouth rehabilitation of edentulous patient with fixed implant prosthesis (고정성 임플란트 보철물을 이용한 완전 무치악 환자의 구강회복 증례)

  • Shi, Hee-Hyun;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.147-156
    • /
    • 2021
  • There are various treatment options such as conventional complete denture, hybrid prosthesis and implant-supported fixed prosthesis for fully edentulous patients. In case of implant-supported fixed prosthesis, compared to removable prosthesis, it is difficult to place the implant in the correct position considering the anatomical contours of the final prosthesis. In this case, a full mouth rehabilitation with implant-supported fixed prosthesis was performed for a patient who required extraction of all remaining teeth due to dental caries and chronic periodontitis. In the implant placement stage, the implant was placed in the desired position using a surgical guide fabricated considering the anatomical contours of the final prosthesis, and the function and esthetics were evaluated through correction and re-fabrication of the fixed provisional restoration. A final restoration of porcelain fused to gold prosthesis was delivered to the patient based on the provisional restoration. To cope with complications such as loosening of screws and fracture of porcelain, a screw-retained type prosthesis was fabricated for the posterior part and a screw-cement-retained type prosthesis for the anterior part. As a result, the patient showed an improved prognosis in terms of functional and esthetics after the final prosthesis was delivered.

Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown (즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복)

  • Kim, Yu-Lee;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.

Removal of fractured implant screws: case report (파절된 임플란트 나사의 제거: 증례보고)

  • Kim, Tae-Su;Lee, Jae-Hyun;Lee, Won-Sup;Lee, Su-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • Screw loosening and screw fracture of abutment is one of most frequent mechanical complications in implant restoration. Fractured fragments in implant restoration like abutment and screw should be completely removed and the procedure needs minimal damage to the fixture of implant. In some cases, it could fail to remove fractured fragments and cause a lot of damage to the fixture of implant. These situations could render implant unusable at the worst. This article describes three different situations and simple techniques for successful removal of fractured fragments without damage of implants. The procedures used are described in this clinical report.

Digital impression taking for full-arch implant restoration to a patient with microstomia (디지털 인상채득을 이용한 소구증을 가진 환자의 전악 임플란트 수복)

  • Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.616-621
    • /
    • 2018
  • This clinical case highlights the failure of long length implants, and the prosthodontic procedures necessary to rehabilitate the maxillary dentition of a patient with microstomia. The integrated digital technology of intra-oral scanning, computer-aided design, and three-dimensional printing can provide an alternative method to make conventional impressions for patients with microstomia who cannot insert the appropriate tray in their mouths.

  • PDF

I-shaped incisions for papilla reconstruction in second stage implant surgery

  • Lee, Eun-Kwon;Herr, Yeek;Kwon, Young-Hyuk;Shin, Seung-Il;Lee, Dong-Yeol;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.3
    • /
    • pp.139-143
    • /
    • 2010
  • Purpose: Pink gingival esthetic especially on the anterior teeth has been an important success criterion in implant-supported restoration. Inter-implant papillae are a critical factor for implant esthetics, and various techniques for inter-implant papilla reconstruction have been introduced. The aim of this study is to suggest and evaluate a surgical technique for reconstructing inter-implant papillae. Methods: A 28-year-old man had an implant placed on the #13 and #14 area. Four months after implant placement, a second stage surgery was planned for inter-implant papilla reconstruction. At the time of the abutment connection, I-type incisions were performed on the #13i & #14i area followed by full-thickness flap elevation and connection of a healing abutment on underlying fixtures without suture. Results: Two weeks after the second stage implant surgery, soft tissue augmentation between the two implants was achieved. Conclusions: I-shaped incisions for papilla reconstruction performed during the second stage implant surgery were useful for inter-implant papilla reconstruction and showed a good esthetic result.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.