• Title/Summary/Keyword: implant overdenture

Search Result 173, Processing Time 0.019 seconds

Overdentures of the patient with Parkinson's disease: A case report (파킨슨 병을 가진 환자의 상악 마그네틱 피개의치 및 하악 임플란트 피개의치 수복 증례)

  • Min, Byung-Kwee;Shin, Eun-Jung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yun, Kwi-Dug;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.352-358
    • /
    • 2015
  • The retention of complete dentures in patients with Parkinson's disease is often poor due to their constant dislodgement by involuntary movements of the tongue and lips. Furthermore, insertion of the overdenture is expected to be difficult due to their limited voluntary movements. This case is about the bimaxillary overdenture restoration where its retention and stability are improved, using magnetic attachment of remained roots of maxilla and two implant $Locator^{(R)}$ attachments of mandible in patients with Parkinson's disease. This report describes the fabrication of this functionally improved prosthesis.

Implant-assisted removable partial denture using Milled-Bar and Attachment in partially edentulous maxilla: A case report (상악 부분 무치악 환자에서 Milled-bar와 어태치먼트를 이용한 임플란트 부분 피개의치 수복 증례 보고)

  • Jeong, Yun-Su;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.412-419
    • /
    • 2022
  • For treatment of partially edentulous patients, a treatment using implant is widely used. Treatment method using implant are implant fixed prostheses and removable partial dentures, and for patients with severe bone resorption, removable implant overdenture with the effects of aesthetic and reducing cost can be used as treatment options. Specially, prosthesis with milled-bar and attachment has the effect of being splinted between implant fixtures, higher retention and stability than conventional removable partial denture. And it has the effect of improvement of aesthetic through lip support by denture base. In this case, the patient with severe alveolar bone resorption and partial edentulous maxilla and mandible was treated by implant-assisted removable partial denture using Milled-bar and ADD-TOC attachment. The esthetic was improved by removing the clasp because of effects of additional retention by using the attachment, and reducing palatal coverage of implant-assisted removable partial denture. The clinical results were satisfactory on the aspect of aesthetic and masticatory function.

Eight-year follow-up of two different removable prostheses using six implants in maxillary edentulous patients (상악 완전 무치악 환자에서 6개의 임플란트를 동반한 두가지 가철성 의치 치료의 8년 경과 관찰 증례)

  • Yang, Seung-Won;Kim, Jong-Eun;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.300-304
    • /
    • 2017
  • An implant-supported fixed dental prosthesis (ISFDP) or an implant-supported overdenture (IOD) are good options when treating a completely edentulous jaw opposing natural teeth. However, an ISFDP for a full arch requires sufficient bone quality and quantity, which limits its application. Meanwhile, using an ISFDP as an abutment of a removable partial denture has been considered recently. This clinical report discusses the treatments applied to two patients with edentulous maxillas and opposing natural teeth: one was treated with an IOD and the other was treated with an ISFDP and removable partial denture. Follow-up and management were performed for 8 years.

Retreatment of implant overdenture using Milled Bar and Attachment in a patient using a unilateral prosthetic arm: A case report (편측 의수 사용 환자에서 Milled Bar와 Attachment를 이용한 임플란트 피개의치 재수복 증례)

  • Park, So-Hyung;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, So-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.187-194
    • /
    • 2022
  • The use of implants could improve the support, retention, and stability of removable prosthetic restoration for fully edentulous patients with severe alveolar bone resorption. When the prosthesis is manufactured without accurate diagnosis and evaluation, this may lead to unfavorable treatment result. The patient in this case had the treatment of implant overdentures at a private dental clinic, but visited the hospital for retreatment due to soft tissue pain and decreasing retention of existing dentures. The vertical dimension was raised compared to the existing dentures, and overdentures were manufactured using milled bars and additional attachments. The clinical results were satisfactory in the aspect of improved oral hygiene maintenance, function and esthetics.

치조제 분리술을 이용한 임프란트의 식립증례

  • Kim, Mi-Seong;Nam, Ok-Hyeon;Kim, Su-Gwan;Jo, Se-In;Kim, Sik;Kim, Hyeon-Ho;Gwon, Byeong-Gon
    • The Journal of the Korean dental association
    • /
    • v.40 no.9 s.400
    • /
    • pp.709-715
    • /
    • 2002
  • Two patients with sufficient vertical bone height but insufficient bone width in the anterior mandibular edentulous area, less than 6mm in the buccolingual aspect, for implant placement were chosen for treatment with a ridge splitting procedure. The surgical technique involving greenstick fracture is described. This ridge splitting procedure could be simple placement of implants into ideal restorable positions in severely atrophic, knife-edged ridges and predictable for narrow edentulous alveolar ridge augmentation associated with implant placement. We experienced two cases to place implant with insufficient bone width in the anterior mandibular edentulous area for overdenture be ridge splitting technique. Thus, we will report two cases and review of the literature.

  • PDF

Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report (CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례)

  • Lee, Han-na;Shim, Ji-Suk;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.374-381
    • /
    • 2022
  • This case report introduces a 74-year-old male patient who visited retention deficiency of the mandibular implant overdenture, which was fabricated 20 years ago. When the existing dentures were used, the vertical dimension was reduced, the maxillary complete denture lacked lip support and retention, and the mandibular overdenture lacked clip retention due to damage to the bar attachment. After removing the damaged bar attachment, it was replaced with a ball attachment, and impressions were taken using the DENTCATM Tray and then the vertical dimension was measured. The gothic arch tracing was performed to record the centric relation. Obtained impressions were scanned and the shape of final dentures was designed using software and try-in dentures were fabricated using 3D printer. After evaluating the occlusal plane, occlusal relationship, facial shape, and pronunciation using the try-in dentures, the bite registration was recorded, and the final denture was manufactured based on this. The inner surface of the denture was adjusted and bilateral balanced occlusion was formed, and the housing was connected to the mandibular denture by a direct method. This case reports have shown satisfactory resultin recovering improved retention and esthetic outcome by increasing the vertical dimension and the lip support using CAD-CAM technique and the ball attachment.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Prosthetic rehabilitation of a patient with tongue cancer using palatal augmentation prosthesis and mandibular implant-retained overdenture: A case report (구개 증대 보철물과 임플란트 피개의치를 이용한 설암 환자의 보철수복 증례)

  • Kim, Ye-Jin;Lee, Young-Hoon;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.317-322
    • /
    • 2018
  • The tongue, especially its lateral part, is the most common site of oral tumors. Patients who undergo glossectomy for the treatment of tongue cancer may experience difficulty in proper functioning for pronunciation, chewing, swallowing, and oral hygiene maintenance; therefore, a palatal augmentation prosthesis can be used to restore function of the tongue. In this case, an implant overdenture was used in a patient who had residual ridge resorption and obliteration of alveololingual sulcus after undergoing glossectomy for tongue cancer treatment. In addition, a palatal augmentation prosthesis with a metal framework, support, and retention part was fabricated. The palatal vault was reduced, so that even with limited tongue movement, adequate tongue-palate contact could be achieved. After placement of the definitive prostheses, the patient showed improvement in the functions of chewing, swallowing, and pronunciation.

NOVEL TREATMENT MODALITY OF IMPLANT-RETAINED OVERDENTURE FOR IMMEDIATE FUNCTION IN COMPLETELY EDENTULOUS PATIENTS (무치악 환자에서 하악 임플랜트 지지 피개의치에 의한 즉시 하중 부담에 관한 연구)

  • Kim, Jang-Wook;Kim, Hyeong-Seob;Baik, Jin;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.34-47
    • /
    • 2007
  • Statement of problem: Conventional mandibular complete denture lacks in support and stability for edentulous patients to use. Purpose: To enhance support and stability of mandibular complete denture, 2 implants were inserted on the inter-mental foramina space of edentulous patients. With 2 magnetic attachments on the inner side of the overdenture, we gave immediate loads and evaluated the stability of the implants, the responses of the supporting tissues, and the satisfaction of the patients. Material & methods: 6 edentulous patients (5 male, 1 female) each recieved 2 SLA implants in the inter-mental foramina region and implants were immediately loaded with overdenture with magnet attachments. To evaluate the implants stability and the peri-implant tissues, clinical exams, RFA tests and radiographic exams were preformed at the 1 week, 2wks, 6wks, 12wks, and 24wks. post- surgery. Results: The mean surgery time was $45.7{\pm}7.7mins$., while the denture delivery time was $45.5{\pm}12.6mins$. Only 2 of 14 implants were failed. Survived implants that remained were clincally and radiographically stable. Mean ISQ values were relatively stable, showing $69.71{\pm}5.55$, $69.00{\pm}9.48$, $67.92{\pm}7.86$, $67.92{\pm}9.58$, $70.08{\pm}7.61$, $71.92{\pm}6.43$ at the 1 wk, 2 wks, 6 wks, 12 wks, 24 wks. follow up check. Crestal bone changes were $-1.18mm{\pm}0.68mm$, $-1.35{\pm}0.69mm$, $-1.47{\pm}0.68mm$ at the 6wks, 12wks, 24wks. follow up check. Bleeding on probing(BOP index) was not significant. Conclusion: Mandibular ovedentures with 2 magnetic attachments over two interforaminal implants on edentulous patients for immediate function is a recommendable novel treatment for edentulous patients which shows stability on the implants and supporting tissue.

A Study on the Retentive Force of Stud Attachments for Implant Overdenture (임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구)

  • Song, Eun-Ju;Bae, Eun-Bin;Choi, Jae-Won;Bae, Ji-Hyeon;Kim, Ji-Young;Lee, So-Hyoun
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.93-100
    • /
    • 2016
  • The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.