• Title/Summary/Keyword: impact protection performance

Search Result 158, Processing Time 0.025 seconds

The Impact of Eco-friendly Management on Product Quality, Financial Performance and Environmental Performance

  • Ma, Jin-Hee;Choi, Seok-Beom;Ahn, Young-Hyo
    • Journal of Distribution Science
    • /
    • v.15 no.5
    • /
    • pp.17-28
    • /
    • 2017
  • Purpose - Considering the environmental issues in corporate management is now a necessity, not an option. In addition, consumers' interest in health and environment has increased rapidly. This study aims to investigate how the management style that pursues environmental protection affects the various outcomes at each management process such as planning, producing and supervising process. Research design, data, and methodology - We surveyed 319 manufacturing companies from April 1 to April 30, 2016. Green purchasing, environmental technology management and management support are selected as independent variables and firm performances as dependent variables. Three analyses including factor, regression and moderating were conducted. Results - Regression analysis was performed to set up hypotheses. Consequently, the total six hypotheses were adopted and then innovative management style showed moderating effect. Conclusions - Companies should consider environmental factors to improve the financial performance in the long term. Especially the cooperative style enhances financial performance by implementing eco-friendly design in cooperation with customers. Also, eco-friendly activities with suppliers could have direct environmental protection effects. Therefore, a manufacturer needs to cooperate with both suppliers and customers to maximize the protection effect. The production of eco-friendly products and implementing eco-friendly design with customers positively affect product quality.

Investigation on the Applicability of Structures by Evaluating the Static Properties and the Impact Resistance Performance of Amorphous Metallic Fiber Reinforced Cement Composites (비정질 강섬유보강 시멘트복합체의 정역학특성 및 내충격성능 평가를 통한 구조물 적용 가능성 검토)

  • Kang, Il-Soo;Kim, Gyu-Yong;Lee, Bo-Kyeong;Lee, Sang-Kyu;Son, Min-Jae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.79-80
    • /
    • 2017
  • This study examined the effect that the amorphous metallic fibers had on the static mechanical properties and the impact resistance of cement composites to those of hooked steel fibers. The hooked steel fiber exhibited pull-out from the matrix after the peak flexural stress was attained, while the amorphous metallic fiber was not pulled out from the matrix, but was instead cut off. In terms of impact resistance, the amorphous metallic fiber reinforced cement composite was found to be more effective at resisting cracking than the hooked steel fiber reinforced cement composite. Therefore, amorphous metallic fiber should be used in fiber reinforced cement composite materials, and for structural materials, and for protection panels.

  • PDF

A Study on the high-velocity impact resistance of fiber reinforced metal laminate materials (섬유강화 금속 적층 재료의 고속 충격 저항성에 관한 연구)

  • 손세원;김영태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1378-1381
    • /
    • 2003
  • Recently, high-performance composite materials have been used for various industrial fields because of their superior high strength, high stiffness and lower weight. In this study, manufactured fiber reinforced metal laminate materials are composed of two parts. One is hard-anodized A15083-O alloy as a face material and the other is high strength aramid fiber (Twaron CT709) and polyethylene fiber(Dyneema HB25) laminates as a back-up material. Resistance to penetration is determined by protection ballistic limit(V$\sub$50/, a static velocity with 50% probability for complete penetration) test method. V$\sub$50/ tests with 0$^{\circ}$ obliquity at room temperature were conducted with 5.56mm ball projectiles that were able to achieve near or complete penetration during high velocity impact tests.

  • PDF

Experimental study on fracture properties with re-bar reinforcement of cement composite subjected to impact of high-velocity projectile (고속 발사체 충격을 받은 시멘트 복합체의 철근보강에 따른 파괴 특성에 관한 실험적 연구)

  • Seok, Won-Kyun;Kim, Gyu-Yong;Nam, Jeong-Soo;Lee, Yae-Chan;Jeon, Hyun-Soo;Kim, Young-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.220-221
    • /
    • 2022
  • With reent changes in energy sources, infrastructure facilities for energy charging are increasing around living areas. The infrastructure facilities have a slight possibility of explosion, and for this research on protection is needed. In this study, the performance of the reinforcement type is reviewed by examining the destructive properties after applying the impact by the high-velocity projectile to the cement composite to which various reinforcement methods are applied.

  • PDF

Performance Assessment of Flexible Wire Rope Rockfall Protection Fence for 100 kJ Energy Absorption (100 kJ 낙석에너지 흡수가 가능한 유연성 와이어로프 낙석방지울타리 성능검증)

  • Son, Jing-ik;Shin, Yong-chul;Kim, Jung-woo;Moon, Hyung-Bum;Lee, Kyung-soo
    • The Journal of Engineering Geology
    • /
    • v.32 no.4
    • /
    • pp.499-511
    • /
    • 2022
  • In this study, a vertical drop test was carried out to identify the performance of flexible wire rope rockfall protection fence by 100 kJ rockfall energy according to ETAG 027. The flexible wire rope, which consists of wire rope and spring. is especially enhanced the elasticity and flexibility so that it can be longer elongated when the rope is impacted by rockfall compared to original wire rope, and that results longer increase of contact time between rockfall and wire rope and increase rockfall energy absorption capability and decreases rockfall impact force. The test results shows that the plastic deformation occurred in middle post and the final deflection of the middle post was 1.15 m, which is lower than 2.0 m determined by ETAG 027. This vertical test verified the flexible wire rope rockfall protection fence can successfully absorb 102.9 kJ rockfall energy.

Impact of gate protection silicon nitride film on the sub-quarter micron transistor performances in dynamic random access memory devices

  • Choy, J.-H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.2
    • /
    • pp.47-49
    • /
    • 2004
  • Gate protection $SiN_x$ as an alternative to a conventional re-oxidation process in Dynamic Random Access Memory devices is investigated. This process can not only protect the gate electrode tungsten against oxidation, but also save the thermal budget due to the re-oxidation. The protection $SiN_x$ process is applied to the poly-Si gate, and its device performance is measured and compared with the re-oxidation processed poly-Si gate. The results on the gate dielectric integrity show that etch damage-curing capability of protection $SiN_x$ is comparable to the re-oxidation process. In addition, the hot carrier immunity of the $SiN_x$ deposited gate is superior to that of re-oxidation processed gate.

Upper Legform Impact Test of the EURO-NCAP Protocol using a Pedestrian Dummy Model (보행자 더미모델을 이용한 EURO-NCAP 상부다리모형 평가시험 방법에 대한 분석)

  • Park, Sang-ok;Choi, Wook-han;Son, Dae-Geun;Park, Gyung-Jin;Lee, EunDok;Kwon, Hae Boung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.4
    • /
    • pp.14-19
    • /
    • 2017
  • The mortality rate of car-pedestrian accidents is quite high compared to the frequency of accident. Recently, governments and insurance companies tend to establish and implement new safety standards for pedestrian protection such as EURO-NCAP and K-NCAP. The performance for the pedestrian protection has been gradually improved, but it is still insufficient. Therefore, various studies for the pedestrian protection are being carried out. The car-pedestrian accident is simulated in order to study to the upper legform test of the EURO-NCAP protocol. A pedestrian dummy model is employed and the results are discussed.

Study for the Proposal of Design Specifications for Rockfall Protection Fences by Full Scale Tests (현장실험을 통한 낙석방지울타리 설계기준 제시 연구)

  • 박혁진;구호본;이경미;김규한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11b
    • /
    • pp.139-151
    • /
    • 2000
  • Rockfall protection fence is one of the most common rockfall protection measures in Korea. The fences have been constructed in almost every hazardous cutslopes along national highway in Korea. However, the capability and performance of the fence as rockfall protection system are seldom known since no field test which can provide information on the response and the behavior of fence was carried out. This is the first full scaled rockfall test in Korea. The objectives of the test are to provide the information on the behavior and the capability of fence and to propose the design specifications for the fence. In this test, four different systems have been selected and tested. For each test, the rockfall impact energy was analyzed and the response and behavior of the system were investigated.

  • PDF

Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage (아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안)

  • Seongju Oh;Sanghun Han;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.65-77
    • /
    • 2024
  • This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

Enhanced Corrosion Protection Performance by Novel Inhibitor-Loaded Hybrid Sol-Gel Coatings on Mild Steel in 3.5% NaCl Medium

  • Suleiman, Rami K.
    • Corrosion Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.168-174
    • /
    • 2019
  • The sol-gel methodology has been applied successfully in the synthesis of a novel hybrid coating based on dimethoxymethyl-n-octadecylsilane precursor. The newly synthesized parent coating was functionalized further with two commercially-available corrosion-inhibitive pigments Moly-$white^{(R)}$ 101-ED and Hfucophos $Zapp^{(R)}$, applied to mild steel panels, and immersed continuously in 3.5% NaCl electrolytic solution for 288 h. The corrosion protection performance of the prepared functional coatings was evaluated using electrochemical impedance spectroscopy (EIS) and DC polarization techniques. An enhancement in the barrier properties has been revealed from the electrochemical characterization data of the hybrid films, in comparison with untreated mild steel substrates following long-term immersion in 3.5% NaCl. The corrosion resistance properties of the newly developed coatings over mild steel substrates found to be largely dependent on the type of the loaded inhibitive pigment in which the Moly-white inhibitor has a positive impact on the corrosion protection performance of the parent coating, while an opposite behavior was observed upon mixing the base polymeric matrix with the commercially-available Zapp corrosion inhibitor.