• 제목/요약/키워드: image artifact

검색결과 387건 처리시간 0.026초

이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계 (Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid)

  • 안형준;임형규;김명남;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.

Constrained adversarial loss for generative adversarial network-based faithful image restoration

  • Kim, Dong-Wook;Chung, Jae-Ryun;Kim, Jongho;Lee, Dae Yeol;Jeong, Se Yoon;Jung, Seung-Won
    • ETRI Journal
    • /
    • 제41권4호
    • /
    • pp.415-425
    • /
    • 2019
  • Generative adversarial networks (GAN) have been successfully used in many image restoration tasks, including image denoising, super-resolution, and compression artifact reduction. By fully exploiting its characteristics, state-of-the-art image restoration techniques can be used to generate images with photorealistic details. However, there are many applications that require faithful rather than visually appealing image reconstruction, such as medical imaging, surveillance, and video coding. We found that previous GAN-training methods that used a loss function in the form of a weighted sum of fidelity and adversarial loss fails to reduce fidelity loss. This results in non-negligible degradation of the objective image quality, including peak signal-to-noise ratio. Our approach is to alternate between fidelity and adversarial loss in a way that the minimization of adversarial loss does not deteriorate the fidelity. Experimental results on compression-artifact reduction and super-resolution tasks show that the proposed method can perform faithful and photorealistic image restoration.

Computed Radiography 영상에서 Parameter에 의한 Artifact 원인과 해결방안 (Cause and Solution of an Artifact Generation by Parameter in Computed Radiography System)

  • 동경래;최준구;홍성일
    • 한국콘텐츠학회논문지
    • /
    • 제9권5호
    • /
    • pp.145-155
    • /
    • 2009
  • CR방식의 도입으로 인해 많은 장점을 가지게 되었으나 기존의 Film/Screen방식에서 발생되지 않았던 Artifact가 새롭게 발생하였다. 따라서 본 논문에서는 광주에 위치한 일개 종합병원에서 획득한 CR 영상 중 Artifact가 발생한 경우를 3가지로 나누어 측정하였다. 시간 지연과 농도변화에 의한 Artifact는 시간이 경과할수록 자연방사선에 의한 영향으로 1일보다 5일후에 67%의 농도가 증가 되었으며 잠상퇴행에 의한 Artifact는 즉시보다 10시간 후의 빛의 방출도가 33%감소하여 시판이 경과할수록 영상의 질이 저하되었다. 술자에 의한 Artifact는 Collimation에 의한 Artifact가 53%, 기기에 의한 Artifact는 Guiding plate, Suction cup으로 인한 Artifact가 65%로 가장 많이 발생되는 것으로 나타났다. 따라서 Artifact에 대한 정확한 인식을 정기적인 점검을 통해 해결방안을 모색한다면 영상의 질 및 진료의 만족도를 높여 갈 수 있을 것이다.

치과 교정 물질에 따른 자기공명영상의 왜곡 (Distortion of Magnetic Resonance Imaging for Different Types of Orthodontic Material)

  • 송현옥;임청환;이상호;양오남;백창무;정홍량
    • 디지털융복합연구
    • /
    • 제12권2호
    • /
    • pp.439-446
    • /
    • 2014
  • 자기공명영상검사에서 치과 교정용 금속 물질에 의한 인공물(Artifact)의 영향을 평가하기 위해 치과 교정에 사용되는 와이어(Wire)와 브라켓(Bracket)을 재질별로 선택하여 비교 연구하였다. 치과 금속을 넣은 사각 아크릴 용기는 $200{\times}135{\times}120mm$ 크기이며, 영상을 얻기 위하여 두부 코일을 사용하여 $T_2$강조영상, $T_1$강조영상, FLAIR영상을 획득하였다. 획득된 시퀀스별 자기공명영상의 인공물을 평가하기 위하여 Image J 프로그램을 사용하여 인공물의 면적을 측정 비교하였다. 연구에서 치과 교정용 와이어와 브라켓의 인공물이 가장 큰 물질은 Stainless steel로 나타났다. 현재까지는 치과 교정에서 교정을 목적에 두고 금속 물질을 선택하였으나 치과 교정용 금속은 환자의 기능과 미의 특성뿐 아니라 자기공명영상 인공물 생성 여부도 함께 고려해야 한다. 추후 교정용 금속의 선택 및 개발 발전은 치아교정의 목적과 더불어 다른 분야도 고려해야 할 것으로 사료된다.

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

전산화단층촬영장치에서 링 아티팩트 제거 (Removal of Ring Artifact in Computed Tomography)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.403-408
    • /
    • 2015
  • 경엑스선은 물체의 내부구조 관찰에 유용하고 의료 및 산업분야에 광범위하게 사용되고 있다. 전산화단층촬영기법은 수백장의 투영영상을 이용하여 재구성함으로써 물체의 2차원 단면 영상을 얻을 수 있다. 단면 영상의 품질은 투영영상에 크게 의존한다. 투영영상을 얻는 검출기의 픽셀에 따라 링 아티팩트가 나타난다. 본 연구는 visual C++기반으로 한 원형 팬텀에서 검출기의 검출 에러에 따른 링 아티팩트 비를 조사하였다. 평행빔 및 부채살빔에서 링 아티팩트 비는 검출기의 검출 에러에 비례하여 나타났고, 회전 중심에 가까울수록 링 아티팩트는 강하게 나타났다. 전산화단층촬영의 단면 영상에서 링 아티팩트를 줄이기 위해서는 영상재구성 이전에 검출기의 보정이 필요함을 알 수 있었다.

Standard와 MAR 알고리즘에서 CT 검사조건 변화에 따른 인공물과 노이즈 평가 (Evaluation of Artifact and Noise in the Standard and MAR Algorithms with Variation of Examination Conditions of CT)

  • 김영근;양숙;왕태욱
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권2호
    • /
    • pp.79-85
    • /
    • 2020
  • The influence of metal artifact in CT image depends on the type of metal materialsm, the reconstruction algorithm, and scan parameters. The presence of metal artifacts was quantitatively evaluated by applying the standard and MAR algorithms through the phantom study. In the change of tube voltage applied the standard algorithm, metal artifact decreased to 44.9% for 80 vs 120 kVp, 24% for 100 vs 120 kVp, while the image taken at 140 kVp increased the artifact by 19% compared to 120 kVp. When the tube current was increased from 100 to 300 mA, there was no significant difference in the CT value and noise. Black band and white strike artifacts occurred up to 65.9% in the adjacent ROI of the metal driver, whereas titanium screw produced lesser metal artifact than that of the metal driver. The combination of 120kVp or higher tube voltage-standard algorithm was effective in removing black band artifacts as well as white streak by high density materials. However, MAR reconstruction algorithm was useful in improving image quality under the environment of low kVp and high density materials, without increase of radiation exposure.

광혈류량 신호의 움직임 훼손 보상 기법 (A Method for Motion Artifact Compensation of PPG Signal)

  • 김한솔;이의철
    • 방송공학회논문지
    • /
    • 제18권4호
    • /
    • pp.543-549
    • /
    • 2013
  • 자율신경계 및 중추신경계 반응 신호는 취득 시 피험자의 움직임이 있는 경우 노이즈가 첨가되어 의도한 분석이 불가능하게 될 수 있다. 본 논문에서는 생리신호 취득시 피험자의 영상을 동시에 촬영 및 분석하고 움직임을 감지하여, 생리신호의 노이즈 구간을 정의하는 방법을 제안한다. 움직임 감지를 위해 시계열에서 영상 프레임간 1차 미분하고 임계치 이상 움직임이 발생했을 때를 해당 신호의 노이즈 발생 구간으로 정의하였다. 또한, 영상을 사용하지 않는 방법으로써, 수집된 신호를 주기 단위로 분석하여 길이와 높이를 특징으로 한 정상 신호를 2차원 가우시안 확률밀도함수로 모델화하여, 신호의 훼손 구간을 정의하는 방법을 제안한다. 두 방법으로 정의된 훼손 구간은 가우시안 함수를 기반으로 보간하였다. 광혈류량 신호에 적용한 결과, 심전도 신호에서 추출된 평균 심박간격에 가까운 수치로 복원됨을 확인하였다. 또한, 영상기반 방법은 정상구간을 훼손구간으로, 신호기반 방법은 훼손구간을 정상구간으로 잘못 인식하는 경우가 나타남을 확인하였다.

웨이블릿 압축된 영상의 정칙화 기반 후처리에 관한 연구 (A Study of Regularized Iterative Postprocessing of Wavelet-compressed Images)

  • 정정훈;정시창;백준기
    • 전자공학회논문지S
    • /
    • 제36S권11호
    • /
    • pp.44-53
    • /
    • 1999
  • 본 논문에서는 웨이블릿 부호와 방식으로 압축된 영상을 정칙화된 영상복원 방법으로 후처리하는 알고리듬을 제안한다. 우선은 웨이블릿 기반 압축 시스템을 영상 열화 시스템(image degradation system)으로 적절히 모델화한다. 그리고 비선형 함수를 정칙화 과정의 제약조건으로 사용함으로써 고주파 성분 계수들의 손실 때문에 발생하는 링 현상(ringing artifact) 및 블록화 현상(blocking artifact)과 같은 열화들을 효과적으로 제거하는 방법을 제안한다. 또한, 실험 결과를 토대로 기존의 후처리 방법과 제안된 알고리듬의 성능을 비교한다.

  • PDF

강자성 인공물 발생에 대한 자기공명영상 질 평가: 1.5T와 3.0T 비교 (Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T.)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.193-199
    • /
    • 2018
  • 본 연구는 총 15명의 정상인 지원자를 대상으로 1.5T와 3.0T의 자기공명영상기기(Philips, Medical System, Achieva)를 이용하여 강자성 인공물을 최소화하기 위한 최적의 Tesla를 알아보고자 하였다. 평가는 신호대 잡음비 평가, 강자성 인공물이 형성된 부위의 길이와 Histogram을 평가하였다. 분석방법으로는 T1, T2 sagittal 영상의 Background의 4 부위에 관심영역을 설정하고 L3, L4, L5의 각 추체부에 관심영역을 설정한 후 신호대잡음비 값을 측정하였고, 인공물이 형성된 3 부위에 관심영역을 설정하고 길이 값을 측정하였고, Image J 프로그램을 이용해 인공물 영역의 히스토그램 분포 값을 측정하였다. 본 실험에 대한 결과로 신호대 잡음비 평가에서 L3에서는 1.5T와 3.0T 사이에 별 차이가 없는 것으로 나타났고, L4, L5에서는 큰 차이가 있는 것으로 나타났다(p<0.05). 강자성 인공물이 형성된 3 부위의 길이는 3.0T에 비해 1.5T가 더 짧아 주변조직에 대한 진단적 정보를 더 얻을 수 있는 것으로 나타났다(p<0.05). Histogram평가에서는 3.0T보다 1.5T가 Count값이 높게 나타났다(p<0.05). 결론적으로 1.5T와 3.0T의 신호대 잡음비, 강자성 인공물의 길이, Histogram을 비교 평가해 봤을 때, Spine MRI 검사 시에 PLIF 등 디스크 수술을 받은 환자에게는 Low Tesla로 검사가 최적의 영상정보를 얻을 수 있었다.