• Title/Summary/Keyword: image analyser

Search Result 42, Processing Time 0.025 seconds

Effect of Processing Agent on Physical Properties of Leather (혁의 물성에 미치는 가공제 첨가 효과)

  • Lee, Jong-Seok;Seo, Gyo-Taeg;Kim, Young Chai;Moon, Sei-Ki
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.934-938
    • /
    • 1999
  • Effect of processing agents on physical properties on aniline-type leathers such as wet blue, crust leather, and finished leather has been investigated. These leathers were manufactured from pelts obtained by the chemical, the enzyme, and the bio-tech treatment. There was no difference in physical properties between crust leather and finished leather. All finished leathers with the three treatments were satisfied with the Korean Industrial Standard like a tensile strength of $1.2kg_f/mm^2$, an elongation of 30%, a tear strength of $3.0kg_f/mm$, a grain crack weight of $15kg_f$, and a $Cr_2O_3$ content of 2.5%. In peculiar, application of the bio-tech treatment gave the best leather. This improvement of physical quality could be explained by the results of SEM and image analyser.

  • PDF

Extension of Storage Time of Chicon using Nanoparticle of Machilus thunbergii Extracts (후박추출물의 나노입자화를 통한 치콘의 저장기간 연장)

  • Kwon, Min-Chul;Han, Jae-Gun;Ha, Ji-Hye;Jin, Ling;Choi, Geun-Pyo;Park, Uk-Yeon;Lee, Dal-Ho;Hyeon-Yong, Lee
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.5
    • /
    • pp.320-325
    • /
    • 2008
  • Machilus thunbergii has been showed relation to antimicrobial activity on minimal inhibitoty concentration (MIC) and colony forming inhibitory activity (CFIA) test, so that can be used to food preservatives for green vegetable. Nanoparticles has been made of edible materials. 80% of the nanoparticles has been characterized by image analyser and electron microscopy, showing in the range under 300 nm diameter. The sprayed nanoparticles remained on the surface of chicon even after washing by dilution water, then activate biological activities for storage of chicon with storing and releasement system of extracts. Chicon treated nanoparticle has been kept fresh condition about 2 months longer than 3 weeks of the non-treated control. It can be tell that treatment with nanoparticle of M. thunbergii extracts extends storage time of chicon possibly by inhibition of ethylene production through efficiency control on cell breathing.

Study on the Repeatability and Reproductivity of a Moire Body Shape Analyser (모아레를 이용한 체형분석의 반복성 재현성에 관한 연구)

  • Lee, Dong-Yup;Park, Young-Bae;Oh, Hwan-Sub
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.121-131
    • /
    • 2006
  • Background : As each human has a look in the face of oneself, he or she has a look of him or herself in the shape of the body also. And for the shape of the body which gives a big clue in diagnosis in musculoskeletal disorders. Therefor many means are used and developed for diagnosis through body shape or posture analysis for musculoskeletal disorders. X-ray, CT, MRI has been used for diagnosis through image in this way to tell about the inside of the human body. On the other side, moire topography was used for information about the exterior of the human body, but yet only minimal information such as the number of contour lines in each side was available. Therefor there were a few studies to use moire topography or other methods to get information about the surface of the human body in numeric values. The instrument used in this study which is a laser projection moire, is another trial to get numeric data about the surface of the human body. The instrument is composed of laser projector and a computer software to recompose and analyse the image data into depth, height, angle and length. Objectives : The study was focused on whether the instrument is reliable for clinic use, and to seek the proper environment and posture for the examination, and among the data the software provides, which items are more reliable and useful. Methods : For reproductivity and repeatability, 4 testers tested 2 persons. And to how if the body shape changes according to the posture and which posture gives the most reliable data, the test was performed in 6 different positions. Results : Result, the instrument showed sufficient repeatability and reproductivity for clinical use. And among the items the software provides, the length of the back, the angle of the back in the sagittal and coronal plane showed reliable results. And there was difference in the results according to the posture, and Therefor, in following studies using this instrument or similar type of posture analysing instruments, the length of the back, the angle of the back in the sagittal and coronal plane could be reliable item to use.

  • PDF

EXPERIMENTAL STUDY ON THE DISSOLUTION COMPONENTS AND CORROSION PRODUCTS OF SEVERAL AMALGAMS IN ARTIFICIAL SALIVA (인공타액에서 수종 아말감의 부식시 용해성분 및 표면 부식 생성물에 관한 실험적 연구)

  • Cho, Seung-Joo;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.1-26
    • /
    • 1994
  • The purpose of this study was to investigate the dissolution components during corrosion of amalgams and to identify surface corrosion products in the modified Fusayama artificial saliva. Four type of amalgam alloys were used: low copper lathe cut amalgam alloy (Cavex 68), low copper spherical amalgam alloy (Caulk Spherical Alloy), high copper admixed amalgam alloy (Dispersalloy) and high copper single composition amalgam alloy (Tytin). Each amalgam alloy and Hg were triturated according to the manufacturer's direction by means of mechanical amalgamator (Capmaster, S.S.White), and then the triturated mass was inserted into the cylindrical metal mold which was 10mm in diameter and 2.0mm in height and condensed with compression of 150kg/$cm^2$ using oil pressor. The specimens were removed from the mold and stored at room temperature for 7 days and cleansed with distiled water for 30 minutes in an ultrasonic cleaner. The specimens were immersed in the modified Fusayama artificial saliva for the periods of 1 month, 3 months and 6 months. The amounts of Hg, Cu, Sn and Zn dissolved from each amalgam specimen immersed in the artificial saliva for the periods of 1 month, 3 months and 6 months were measured using Inductivity Coupled Plasma Atomic Emission Spectrometry (ICPQ-1000, Shimadzu, Japan) and amount of Ag dissolved from amalgam specimen was measured using Atomic Absorption Spectrophotometry (Atomic Absorption/Flame emission spectrophotometer M-670, Shimadzu, Japan). A surface corrosion products of specimens were analysed using Electron Spectroscopy Chemical Analyser (ESCA PHI-558, PERKIN ELMER, U.S.A.). The secondary image and back scattered image of corroded surface of specimens was observed under the SEM, and the corroded surface of specimens was analysed with the EDX. The following results were obtained. 1. The dissolution amount of Cu was the most in high copper admixed amalgam(Dispersalloy) and the least in high copper single composition amalgam(Tytin). 2. Sn and Zn were dissolved during all the experiment periods, and dissolution amounts were decreased as the time elapsed. 3. Initial surface corrosion products were ZnO and SnO. 4. Corrosion of ${\gamma}$ and ${\gamma}_2$ phase in low copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in low copper spherical amalgam(Caulk Sperical Alloy). 5. Corrosion of ${\gamma}$ and $\eta$' phase in high copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in high copper admixed amalgam(Dispersalloy). 6. Sn-Cl was produced in the subsurface of low copper amalgams and high copper admixed amalgam.

  • PDF

EFFECT OF PULSED ELECTROMAGNETIC FIELD STIMULATION ON THE EARLY BONE CONSOLIDATION AFTER DISTRACTION OSTEOGENESIS IN RABBIT MANDIBLE MODEL (가토 하악골 골신장 후 맥동전자기장이 조기 골경화에 미치는 효과에 대한 연구)

  • Hwang, Kyung-Kyun;Cho, Tae-Hyung;Song, Yun-Mi;Kim, Do-Kyun;Han, Sung-Hee;Kim, In-Sook;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.2
    • /
    • pp.123-131
    • /
    • 2007
  • Introduction: Distraction osteogenesis is widely used as for bone lengthening in patients with maxillofacial deformity and alveolar bone atrophy. One of the major problems in distraction osteogenesis is long consolidation period for 2-3 months, in which the devices have to be fixed on the bone to prevent relapse. It results in scar formation on the face, disturbance of mastication and speech. This study was performed to evaluate the stimulating effect of pulsed electromagnetic field on the early bone consolidation in distraction osteogenesis. Materials and methods: Total 10 rabbit were used (5 for control group, 5 for experimental group). A vertical osteotomy in the mandibular body was performed and the distraction device was fixed. After 5 days distraction was done 1mm per a day for 7 days. A pulsed electromagnetic field (38 Gauss, 60 Hz) was applied for 8 hours per day and it continued for 5 days immediately after distraction in the experimental group. Both groups were sacrificed after 2 weeks. Histological specimens with H&E and Masson Trichrome staining were made and histomorphometrically analysed with image analyser. Results: The device for distraction osteogenesis was displaced in one animal for each group, therefore, only four animals in both groups were evaluated. In both groups, a new bone formation was observed in the distracted area after 2 weeks. The bone formation was enhanced in the experimental groups ($31.76{\pm}8.68%$) compared with control group ($9.94{\pm}3.23%$), its difference was statistically significant (p<0.001). Conclusion: This study suggests that electrical stimulation with electromagnectic field may be effective in the early bone formation after distraction osteogenesis. Further studies with large number of animals are needed before clinical application.

A Scanning electron microscopic study of enamel surface by debracketing of ceramic bracket (도재브라켓의 제거방법에 따른 법랑질표면의 주사전자현미경학적 관찰)

  • Park, Mi-Suk;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.613-622
    • /
    • 1996
  • The purposes of this study were to evaluate and compare the frequency of ceramic bracket fracture, frequency of enamel fracture, bond fracture site, adhesive remnant index after mechanical and electrothermal debracketing, to evaluate effectiveness of high and low speed rotary instrument and ultrasonic instrument during residual adhesive remnants removal, and to measure resin film surface(percentage) using by image analyser(Leco 300). Bond fracture site, bracket fracture, and enamel surface damage were examined by scanning electron microscope. The following results were obained : 1. In the mechanical debracketing group, the bond failed predominantly at enamel-adhesive interface with the bulk of adhesive remaining on bracket base. 2. In the eletrothermal debracketing group, the bond failed predominantly at adhesive-bracket interface with the bulk of adhesive remaining on enamel surface. 3. The most effectiveness of residual resin removal was obtained by means of the resin polishing bur and the order of scratch formation was the procedure using tungsten carbide bur, ultrasonic scaler, sof-lex disc, and polishing bur. 4. The order of the resin film surface percentage was ultrasonic scaler, tungsten carbide bur, sof-lex disc, and resin polishing bur.

  • PDF

A STUDY ABOUT EARLY OSTEOCONDUCTIVITY OF POROUS ALLOPLASTIC CARBONAPATITE AND ANORGANIC BOVINE XENOGRAFT IN CANINE MAIXLLIARY AUGMENTATION MODEL (탄산아파타이트로 된 인공골과 소뼈에서 유래한 무기질 골의 초기 골전도에 대한 연구)

  • Kim, Do-Kyun;Cho, Tae-Hyung;Song, Yun-Mi;Pan, Hui;Lee, Su-Yeon;Jin, Im-Geon;Kim, In-Sook;Hong, Kug-Sun;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.6
    • /
    • pp.485-493
    • /
    • 2007
  • Introduction: Although several types of calcium-phosphate coumpound have been frequently applied to osseous defects at maxillofacial area for many years, there is a controversy about its efficiency on bone conductivity comprared to xenograft bone substitute. Alloplastic carbonapatite has been introduced to improve disadvantages of hydroxyapatite and to mimic natural bone containing carbon elements. However, a preclinical study about its efficiency of osteoconductivity has not been reported. This study was performed to evaluate the early osteoconductive potential of synthetic carbonapatite with multiple pores relative to anorganic bovine xenograft. Materials and methods: Total 5 beagle dogs were used for maxillary augmentation model. The control (anorganic bovine xenograft) and experimental groups (synthetic carbonapatite) were randomly distributed in the mouth split design. After bone graft, all animals were sacrificed 4 weeks after surgery. Histological specimens with Masson Trichrome staining were made and histomorphometrically analysed with image analyser. The statistical analysis was performed using paired t-test. Results: In both groups, all animals had no complications. The experimental group showed relatively much new bone formation around and along the bone substitutes, whereas it was clearly reduced in the control group. The ratios of new bone area to total area, to material area and to the residual area excluding materials were higher in the experimental group ($0.13{\pm}0.03,\;0.40{\pm}0.13,\;0.20{\pm}0.06$ respectively) than in the control group ($0.01{\pm}0.01,\;0.03{\pm}0.02,\;0.03{\pm}0.03$, respectively). And the differences between both groups were statistically significant (p<0.001, <0.01, <0.01, respectively), while the ratio of material area to total area in two groups was not significant. Conclusion: Carbonapatite showed a high osteoconductivity in the early stage of bone healing compared to bovine derived anorganic bone substitute. This study suggests that this bone materials can be applied as a reliable bone substitute in the clinical treatment.

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

Effects of MethyIxanthine Derivatives on Induction and Enhancement of Hamster Epididymal Sperm Motility (Hamster 정소상체 정자의 운동성 유도와 증가에 영향을 미치는 Methylxanthine Derivatives 의 효과)

  • Park, Y.S.;Song, S.J.;Lee, H.J.;Lee, S.J.;Kim, N.H.;Lee, H.T.;Chung, K.S.
    • Korean Journal of Animal Reproduction
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 1999
  • This study were performed the effect of methylxanthine derivatives on hamster epididymal sperm motility. To assess the effect of methylxanthine derivatives on motility kinematics of epididymal sperm, pentoxifylline, 2-deoxy-adenosine and hypoxanthine were added to TALP medium. 1 mM of pentoxifylline, significantly increased VCL, VAP, VSL of spermatozoa obtained from corpus and cauda epididymis. With 1 mM of 2-deoxyadenosine, VCL, VAP, VSL of spermatozoa obtained from corpus and cauda epididymis were significantly increased, but 2 mM ADE for cauda spermatozoa was effective than 1 mM. In the case of hypoxanthine, various concentrations were not significantly effective, but 2 mM HX showed higher effect than other concentrations. pentoxifylline 1 mM and 2-deoxyadenosine 1 mM significantly increased VCL, VAP of corpus and cauda epididymal spermatozoa and VSL of cauda epididymal spermatozoa. From these results it could be concluded that the addition of methylxanthine increase motility kinematics of hamster spermatozoa collected from epididymis.

  • PDF

Tributyltin Chloride (TBTCl) Toxicity on the Growth and Mantle Structure of the Equilateral Venus, Gomphina veneriformis (Bivalvia: Veneridae) (대복, Gomphina veneriformis의 성장과 외투막 구조에 미치는 TBTCl의 독성)

  • Park, Jung-Jun;Lee, Jung-Sick
    • The Korean Journal of Malacology
    • /
    • v.24 no.3
    • /
    • pp.229-241
    • /
    • 2008
  • Changes of growth and histopathological feature in the mantle structure of the equilateral venus, Gomphina veneriformis exposed to tribultyltin chloride (TBTCl) for 36 weeks were observed. Concentrations of TBTCl were 0, 0.4, 0.6, and $0.8{\mu}g/L$. A regression analysis by power function of SPSS was shown that the growth of experimental groups was significantly decreased after 12 weeks of exposure. For histological analysis, mantle tissues were characterized using H-E stain, AB-PAS (pH 2.5) reaction and Masson's trichrome stain, and epidermal layer thickness and mucous cell distribution were analysed using the image analyser. The mantle had 4-folds (inner-inner, inner-outer, middle, and outer) and its epidermal layer consisted of simple epithlia. A periostracum was observed in the periostracal groove between middle and outer fold. Inner epidermal layer consisted of simple ciliated columnar epithelia, but the outer epidermal layer consisted of simple non-ciliated columnar epithelia. Alcian blue positive mucous cells showed blue color (7462c, 653c) in the inner fold, violet color (2583c) in the middle fold, and blue color (647c, 7455c) in inner epidermal layer (numbers in the parenthesis are codes of Pantone process coated color). Hemolymph sinus in the mantle was extended, and mucous cells in inner plica of the middle fold were stained as blue (7455c) and violet (2587c), after 12 weeks of TBTCI exposure. Cilia and striated border were disappeared, and number of mucous cells in the inner epidermal layer was reduced. Serious histopathological changes in middle and outer fold near the periostracum were observed after 36 weeks. Moreover, epidermal layer thickness and mucous cell distribution were showed decreasing tendency as exposure time to TBTCI was increased. Results of this study suggested that TBTCl induced growth disorder with histopathological changes.

  • PDF