• Title/Summary/Keyword: illumination environment

Search Result 449, Processing Time 0.037 seconds

A Study on the Status of Illumination Environment in Workplaces (업무공간의 조명 환경 실태 조사 연구)

  • Choi Han-Hee;Ha Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.6
    • /
    • pp.167-174
    • /
    • 2004
  • The purpose of this study is to examinethe present illumination conditions in office environment and to suggest an efficient illumination plan in office planning process. Illumination conditions in work environment were surveyed in 6 offices to investigate whether the present illumination conditions were appropriate to the work type. The results of this study are as follows: Most of the general Illuminance level in the area of work were all at an adequate level, except one. The average Illuminance level in the all meeting rooms were met for the standard. Illuminance in the all reception area were extremely over the standard, The illuminations of this area were rather designed according to the image of the company than the standard. As for the illumination method in the area of general work, four offices used a general lighting by a direct lighting type, while two offices used a general lighting and a task lighting at the same time. This survey suggested that first, each company should consider illumination plan in the building planning process, second, illumination plan considering the type of places is needed, and third, illumination environment may be differentiated according to the work type. In conclusion, efficient illumination environment should be considered in office building planning process, especially In terms of illumination materials and methods.

A Study on the Simulation and Development of Evaluation Technique of Interior illumination Environment (실내조명환경 제시 및 평가기술 개발에 관한 연구)

  • 진은미;이진숙;김창순
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.11a
    • /
    • pp.172-177
    • /
    • 1998
  • For making high-functional illumination environment and pleasantness to human beings, it is needed to analyze optical characteristics from lightsource as well as to analyze and examine emotional characteristics which respond to optical characteristics systematically. Also, it is Possible to classify lightsource according to function and use based on optical and emotional characteristics systematically and these results can be applied to practical data for professional illumination design field. The aim of this study is to develop technique for evaluating sensibility as well as to accumulate sensibility database through measuring and evaluating emotional reaction to optical characteristics from lightsource. Final aim of this study is to develop simulation and evaluation technique for interior illumination environment, the outline of this paper : 1) operating simulator for various illumination environment 2) developing evaluation methodology for evaluating illumination environment 3) preparing sensibility index through evaluation and analysis The process of this study is as follows. 1) Developing optical evaluation item of lightsource 2) Developing emotional evaluation item of lightsource 3). Analyzing, correlation between optical evaluation item and emotional eveluation item 4) Classifying and selecting object for evaluation 5) Optical measuring and evaluating for lightsource 6) Operating Simulator for illumination environment 7) Emontional measuring and evaluating lightsource and color 8) Developing estimative formula and sensibility index of emotional reaction The results of this study are as follows. 1. Simulator is operated for various illumination environment, and it is proved to be applicable to actual environment. 2. Evaluation and Analysis Techniques is developed for emotional measurement about illumination environment. 3. Estimative formula and sensibility index are prepared, which can estimate the characteristic of lightsource and emotional reaction to interior color

  • PDF

A Study on the Illumination Environment Design of Gallery Spaces on Bong-san culture street in Daegu (대구 봉산문화거리의 갤러리 조명연출계획)

  • Park, Min-Kyoung;Kim, Hyun-Ji;Cha, Sang-Gi;An, Ok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.74-78
    • /
    • 2007
  • This study purports to survey on the illumination environment design in gallery. These gallery spaces need to improve individual illumination environments, in compliance with the recommended ratio of illumination intensity to brightness, and to create a new illumination design using a wide variety of illuminations.

  • PDF

A Study on the Operator Performance According to the Drastic Change of Illumination Level and Lighting Environment of Control Room in Nuclear Power Plants

  • Shin, Kwang Hyeon;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objective: This study describes the change of operator performance in drastic change of illumination level, and proposes an alternative method to cope with it. Background: The control standard of illumination for nuclear power plants(NPPs) is based on the set of limit criteria for maintaining a specific illumination level. However, there is a possibility to cause human errors according to the psychological and physiological influences to operators in the situation of drastic change of illumination such as SBO(Station Black Out), so a basic study is necessary to review the current approach. Method: We assessed the visual fatigue, subjective work load and task performance according to the three illumination situations(Normal Illumination, Emergency Illumination, and Drastic Change of Illumination). Result: Research finding shows that there are not significant differences in task performance between normal illumination (1,000lx level) and emergency illumination (100lx level), only if beyond the dark adaptation limit. However, subjective work load on mental demand and visual fatigue show a potential challenge to visual performance in drastic change of illumination. Conclusion/Application: Several trials can complement this challenge in NPPs by applying 3-way communication, enhancing readability of procedures, and managing the visual factors affecting the operators' performance through a Visual Environment Management Program including visual health aspects, etc.

A Study on the Analysis of Relations between Classroom Illumination and Variation of the Students' Eyesight and Improvement of the Classroom Illumination in Primary School (초등학교 교실조명과 학생시력 변화의 관계분석 및 교실조명개선에 관한 연구)

  • Kim, Jin-Goo;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • According to the recent investigation, the 4th grade students' eyesight weakness was occurred on a large scale in primary school. To improve the classroom illumination environment which affects students' eyesight weakness of the 4th grade student, an analysis of illumination environment and an eyesight acuity for the whole 4th year students was held. In four out of the whole classrooms, each improvement work in illumination has done using different types of luminaires. Re-test of eyesight was held for students who studied under the improved illumination environment for 10 months and students under the environment not improved. Comparative analysis of the results which was obtained from re-test and measurements was carried out. Consequently, influence on the eyesight variation by classroom illumination was analysed and the improvement of classroom illumination was researched.

Actual Conditions on the Illumination Environment of the Study Rooms in the Youth of an Agriculture Village (농촌 청소년 공부방의 조명환경 실태조사)

  • Kim, Hyun-Ji;Jun, Kyoung-Sun;Lee, In-Hyo;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • This study investigated the actual conditions of the illumination environment from agricultural youth study room. The result, average space of the study room was 11.42[$m^2$]. The illuminant uses the fluorescent lamp mainly, Method of using illumination was only general illumination the case which uses 73.8[%]. Method of light distribution was a direct lighting mainly. The house which has a stand illumination was also 45.7[%], The percentage using the stand illumination which was a local illumination was nothing but in 20[%] of the whole subject of investigation, therefore eye work could not effective. The internal illuminance was average 131.82[lx], the desk illuminance was 253.64[lx] which was the minimum permitted limit and poor. Uniformity ratio of illuminance appeared with average 35.61[%]. The satisfaction with 3.93 points to be high for illumination environment, therefore it was thought that the recognition of illumination was very insufficient.

Subjective Evaluation on the Color Temperatures of LED illumination in the Classroom (학교 교실 LED 조명의 색온도에 대한 주관적 평가)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.30-41
    • /
    • 2011
  • This study performs the subjective evaluations of LED illumination conditions according to three types of color temperatures (7,000[K], 5,000[K], 3,000[K]) after employing LED illumination system in the classroom, Since the objective of this study is to develop an artificial lighting conditions like day light comfortable to students in the classroom, the learning effect based on three types of LED illumination conditions are analyzed. Three factors (learning intention, learning environment, learning motivation) are extracted by ANOVA and there are preference differences of LED illumination conditions between learning intention and learning environment factors. Especially, preference differences of LED illumination conditions are existed about calculation, reading and fatigue reduction. The test results of this study can be applied to obtaining high achievement of learning based on the lighting conditions.

A Study on the Relationship between Light Environment and Visitors' Behavior in a Museum - Focus on the Interpretation of Tracking Score and Tracking Frequency with Intensity of Illumination - (박물관 빛 환경과 관람행태의 상관관계에 관한 연구 - 조도에 의한 관람확률과 관람빈도의 해석을 중심으로 -)

  • Lee, Mi-Youn;Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.4
    • /
    • pp.82-89
    • /
    • 2010
  • The studies published up to now, related to the correlation between spatial structure and visitors' behavior in a museum are rather relatively lacking when it comes to the in-depth consideration for the effect of the actual exhibition environment. So the main purpose of this study is to define the correlation between the light environment and the visitors' behavior. Towards this end, this study uses 'space syntax' to quantify the spatial structure with 'integration', 'connectivity' and 'control value'. Meanwhile, 'tracking score' and 'tracking frequency' were selected as the scope among the indices of behavior's analysis. The results of this study are as follows; First, integration and correlation of tracking score and tracking frequency are lowest when it comes to the extra large historical museums where the difference of intensity of illumination by each convex space. Meanwhile, the most considerable effect is exerted by control value. Compared to tracking score, tracking frequency is closely related to 'syntactic variables'. Second, visitors do not take the short cut the dark exhibition space even when very dark exhibition spaces continue after passing through relatively bright space. Analysis of visitors' behavior by control value in the exhibition space composed of this type of intensity of illumination environment is not valid. Third, visitors move to relatively brighter transitional space compared to the exhibition space with low intensity of illumination when passing through dark exhibition continually. Meanwhile, when visitors pass through the exhibition space there is some difference intensity of illumination they move to relatively dark exhibition center among the subsequent exhibition spaces. Accordingly, when the composition of exhibition space that continues onto the environment of low intensity of illumination is inevitable, differentiating intensity of illumination appropriately would be effective in inducing visit to the subsequent exhibition space.

Economical Efficient Evaluation of Lighting Design in Lecture Room (강의실 조명설계의 경제성 평가)

  • Kim, Deog-Goo;Oh, Seong-Bo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.268-273
    • /
    • 2004
  • The visual environment in an educational building, apart from providing the comfortable seeing conditions needed for the performance of a wide variety of work tasks, must also satisfy the psychological and emotional needs of learners. This paper presents study on actual illumination environment of college and comparison of economical efficiency in order to figure out illumination problems. Furthermore, it attempts to suggest an optimum design of lecture room illumination through computer simulation. We try to evaluate economical efficiency of lighting design in lecture room under the illumination plan which is based on illumination maintenance and uniformity ratio that KS. illumination standard sets.

  • PDF

Changes in Electroencephalographic Results and Heart Rate Variability after Exposure to Green Landscape Photographs Correlated with Color Temperature and Illumination Level

  • Lee, Min Jung;Oh, Wook
    • Journal of People, Plants, and Environment
    • /
    • v.24 no.6
    • /
    • pp.639-649
    • /
    • 2021
  • Background and objective: Various images from visual display terminals (VDTs) as well as living lighting are important parts of our daily life; thus, properly controlling the lighting environment - that is, illuminance, color temperature and good images from VDTs - can have a substantial effect on improving the mental health and work efficiency in everyday life. We examined electroencephalography (EEG) and heart rate variability (HRV) responses to various lighting conditions in 25 university students as they viewed images of a green landscape or traffic congestion. Methods: EEG was performed in darkness and when the room was illuminated with 10 different light-emitting diode (LED) color temperatures, while the EEG and HRV responses to green landscape or traffic congestion image stimuli were measured in darkness and during room illumination with three different LED color temperatures. Results: We found a significant difference between darkness and high LED illumination (400 lx) at 7 (CZ, F4, FZ, O1, O2, OZ, and T6) of 30 channels, while the alpha wave activity increased during darkness. In the second experiment, the green landscape image stimuli in the 30 lx-2600 K lighting condition elicited theta wave activity on the EEG, whereas the traffic congestion image stimuli under high LED illumination elicited high beta and gamma wave activities. Moreover, the subjects exhibited better stress coping ability and heart rate stability in response to green landscape image stimuli under illuminated conditions, according to their HRV. Conclusion: These results suggest that lower color temperatures and illumination levels alleviate tension, and that viewing green landscape image stimuli at low illumination, or in darkness, is effective for reducing stress. Conversely, high illumination levels and color temperatures are likely to increase tension and stress in response to traffic congestion image stimuli.