• Title/Summary/Keyword: hydrogen sensor

Search Result 273, Processing Time 0.03 seconds

Improved hydrogen sensing characteristics of flat type catalytic combustible hydrogen gas sensor of micro-structure (평판형 접촉연소식 마이크로 수소센서의 감지특성 향상)

  • Kim, Chan-Woo;Gwak, Ji-Hye;Chun, Il-Su;Han, Sang-Do;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.202-206
    • /
    • 2009
  • Flat type catalytic combustible hydrogen sensors were fabricated using platinum micro-heaters and sensing material pastes. The platinum micro-heater was formed on an alumina substrate by sputtering method. The paste for the sensing materials was prepared using ${\gamma}-Al_2O_3$ 30 wt%, $SnO_2$ 35 wt%, and Pd/Pt 30 wt% and coated on the platinum micro-heater. The sensing performances were tested for the prepared sensors with different substrate sizes. The micro catalytic combustible hydrogen sensors showed quick response time, high reliability, and good selectivity against various gases(CO, $C_3H_8,\;CH_4$) at low operating temperature of $156^{\circ}\C$.

A study on the highly sensitive metal nanowire sensor for detecting hydrogen (수소감지를 위한 고감도의 금속 나노선 센서에 관한 연구)

  • An, Ho-Myoung;Seo, Young-Ho;Yang, Won-Jae;Kim, Byungcheul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2197-2202
    • /
    • 2014
  • In this paper, we report on an investigation of highly sensitive sensing performance of a hydrogen sensor composed of palladium (Pd) nanowires. The Pd nanowires have been grown by electrodeposition into nanochannels and liberated from the anodic aluminum oxide (AAO) template by dissolving in an aqueous solution of NaOH. A combination of photo-lithography, electron beam lithography and a lift-off process has been utilized to fabricate the sensor using the Pd nanowire. The hydrogen concentrations for 2% and 0.1% were obtained from the sensitivities (${\Delta}R/R$) for 1.92% and 0.18%, respectively. The resistance of the Pd nanowires depends on absorption and desorption of hydrogen. Therefore, we expect that the Pd nanowires can be applicable for detecting highly sensitive hydrogen gas at room temperature.

A Hydrogen Sensor Experiment on the Ventilation Performance of a Cavity upon Hydrogen Leakage and Its CFD Simulation (수소 센서를 이용한 밀폐공간의 수소 누출 시 환기성능에 대한 실험 및 CFD 시뮬레이션)

  • Kim, Young-Doo;Shin, Dong-Hoon;Chung, Tae-Yong;Nam, Jin-Hyun;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.59-62
    • /
    • 2007
  • 연료전지는 수소를 이용하여 전기를 생산하는 발전 시스템으로 운전 중 수소 누출과 폭발의 위험성을 항상 수반하고 있다. 따라서 안전성의 확보를 위해 연료전지 시스템 내부에서 수소 누출 시 유e동 특성으로 인한 특정 부근 농도 정체와 환기의 영향을 파악하는 것이 필요하다. 실험 장치와 전산유체역학 프로그램을 사용하여 챔버 내 수소의 유통 특성과 환기구에 따른 환기의 영향을 확인하였다. 수소의 누출 속도와 양에 따라 유동장의 형태는 크게 변하였으며 환기구의 위치와 크기는 특정 부근의 농도정체와 챔버 내 전체적인 수소 농도에 영향을 미침으로서 안정성을 확보하는 중요한 인자임을 알 수 있었다. 예측 결과를 실제 실험 모델과 비교하여 그 타당성을 검토하였으며 차후 가정용 연료전지 모듈의 환기구 설계에 적용할 수 있다.

  • PDF

Reliability Test of Pd Nanogap-Based Hydrogen Sensors (Pd 나노갭 수소 센서의 신뢰성 연구)

  • Park, Seyoung;Kim, Wonkyung;Lee, Wooyoung
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.399-406
    • /
    • 2020
  • Pd nanogap hydrogen sensors were developed using an elastomeric substrate and operated through an on-off mechanism. A 10 nm thick Pd thin film was formed on a polydimethylsiloxane (PDMS) substrate, and 50% of the physical strain was applied in the longitudinal direction to fabricated uniform nanogaps. The initial concentration of the hydrogen gas for the PDMS/Pd films was controlled, and subsequently, the on-off switching response was measured. We found that the average nanogap was less than 50 nm, and the Pd nanogap hydrogen sensors operated over a wide range of temperatures. In particular, the sensors work properly even at a very low temperature of -40℃ with a fast response time of 2 s. In addition, we have investigated the relative humidity and annealing effects.

Hydrogen Sensor Based on A Palladium-Coated Long-Period Fiber Grating Pair

  • Kim, Young-Ho;Kim, Myoung-Jin;Park, Min-Su;Jang, Jae-Hyung;Lee, Byeong-Ha;Kim, Kwang-Taek
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.221-225
    • /
    • 2008
  • We propose a simple hydrogen detection scheme based on a Mach-Zehnder interferometer formed with a pair of palladium-coated long-period fiber gratings (LPGs). Since an LPG pair offered a fine-structured interference fringe in its transmission spectrum, the resolution as a sensor could be appreciably enhanced compared to that of a single LPG. As the palladium layer absorbed hydrogen, the effective refractive indices of the cladding modes were increased so that the interference spectrum was blue-shifted up to 2.3 nm with a wavelength sensitivity of -0.29 nm/min for 4% of hydrogen concentration.

Room Temperature Hydrogen Gas Sensor Based on Carbon Nanotube Yarn (상온감지 가능한 탄소나노튜브 방적사 기반의 수소 감지 센서)

  • Kim, Jae Keon;Lee, Junyeop;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.132-136
    • /
    • 2018
  • We report the development of a room-temperature hydrogen ($H_2$) gas sensor based on carbon nanotubes (CNT) yarn. To detect $H_2$ gas in room temperature, a highly ordered CNT yarn was placed on a substrate from a spin-capable CNT forest, followed by the deposition of a platinum (Pt) layer on surface of the CNT yarn. To examine the effect of the Pt-layer on the response of the CNT sensor, a comparative sensing performance was characterized on both the Pt deposited and non-deposited CNT yarn at room temperature. The Pt-CNT yarn yielded high response, whereas the non-deposited CNT yarn showed negligible response for $H_2$ detection at room temperature. Pt is a reliable and efficient catalyst that can substantially improve the detection of $H_2$ gas by chemical sensitization via a "spillover" effect. It can be efficiently utilized to increase the sensitivity and selectivity as well as to obtain fast response and recovery times.

Polyester (PET) Fabric dyed with Lead (II) acetate-based Colorimetric Sensor for Detecting Hydrogen Sulfide (H2S) (황화수소(H2S) 감지를 위한 아세트산 납이 침염된 폴리에스터(PET) 섬유 기반의 변색성 센서)

  • Lee, Junyeop;Do, Nam Gon;Jeong, Dong Hyuk;Jung, Dong Geon;An, Hee Kyung;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.360-364
    • /
    • 2020
  • In this study, the colorimetric sensor, polyester (PET) fabric dyed with lead (II) acetate (Pb(C2H3O2)2), was fabricated and characterized for the detection of the hydrogen sulfide (H2S). The surface morphology of the fabric was determined using scanning electron microscope and energy-dispersive X-ray spectroscopy. The optical properties of the fabric were evaluated by measuring the variation in the blue value of an RGB sensor. The fabric showed a significant color change, high linearity (R2 : 0.98256), and fast response time (< 1.0 s) when exposed to H2S. This is because the sensor is highly porous and permeable to the gas. The fabric can not only be used as a hydrogen sulfide sensor but also be used to detect and prevent H2S influx using sticky tape on pipelines.

Feasibility Study of Embedded FBG Sensors for the Smart Monitoring of High Pressure Composite Vessel (복합재 고압용기의 스마트 모니터링을 위한 FBG 센서의 삽입 적용성에 관한 연구)

  • Park, Sang-Wuk;Park, Sang-Oh;Kim, Chun-Gon
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.33-36
    • /
    • 2005
  • In this research, for the smart health monitoring of the hydrogen storage high pressure composite vessel, the feasibility study of an embedded fiber Bragg grating(FBG) sensor is carried out. To verify strain measurement in various temperature environment which is needed for the hydrogen pressure vessel, tensile test of a composite specimen with both an embedded FBG sensor and a strain gauge is made in low temperature. Before we try a real-size hydrogen storage pressure vessel, a small & cheap composite pressure vessel having the same structure is fabricated with embedded FBG sensors and tested. In the case of an aluminum liner inside the vessel, survivability of FBG sensors at the interface is lower than the other areas.

  • PDF

Position-Selective Metal Oxide Nanostructures using Atomic Thin Carbon Layer for Hydrogen Gas Sensors

  • Yu, Hak Ki
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.369-373
    • /
    • 2020
  • A hydrogen sensor was fabricated by utilizing a bundle of metal oxide nanostructures whose growth positions were selectively controlled by utilizing graphene, which is a carbon of atomic-unit thickness. To verify the reducing ability of graphene, it was confirmed that the multi-composition metal oxide V2O5 was converted into VO2 on the graphene surface. Because of the role of graphene as a reducing catalyst, it was confirmed that ZnO and MoO3 nanostructures were grown at high density only on the graphene surface. The fabricated gas sensor showed excellent sensitivity.

Effects of Metal-Organic Framework Membrane on Hydrogen Selectivity

  • Suh, Jun Min;Cho, Sung Hwan;Jang, Ho Won
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.374-381
    • /
    • 2020
  • Hydrogen gas has attracted considerable attention as a promising candidate for future energy resources because of its eco-friendly characteristics; however, its highly combustible characteristics should be thoroughly examined to preclude potential disasters. In this regard, a highly sensitive method for the selective detection of H2 is extremely important. To achieve excellent H2 selectivity, the utilization of a metal-organic framework (MOF) membrane can physically screen interfering gas molecules by restricting the size of kinetic diameters that can penetrate its nanopores. This paper summarizes the various endeavors of researchers to utilize the MOF molecular sieving layer for the development of highly selective H2 sensors. Further, the review affords useful insights into the development of highly reliable H2 sensors.