• Title/Summary/Keyword: hydrogen sensing

Search Result 145, Processing Time 0.028 seconds

Fabrication of Pt-MWNT/Nafion Electrodes by Low-Temperature Decal Transfer Technique for Amperometric Hydrogen Detection

  • Rashid, Muhammad;Jun, Tae-Sun;Kim, Yong Shin
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.1
    • /
    • pp.18-25
    • /
    • 2014
  • A Pt nanoparticle-decorated multiwall carbon nanotube (Pt-MWNT) electrode was prepared on Nafion by a hot-pressing at relatively low temperature. This electrode exhibited an intricate entangled, nanoporous structure as a result of gathering highly anisotropic Pt-MWNTs. Individual Pt nanoparticles were confirmed to have a polycrystalline face-centered cubic structure with an average crystal size of around 3.5 nm. From the cyclic voltammograms for hydrogen redox reactions, the Pt-MWNT electrode was found to have a similar electrochemical behavior to polycrystalline Pt, and a specific electrochemical surface area of $2170cm^2mg^{-1}$. Upon exposure to hydrogen analyte, the Pt-MWNT/Nafion electrode demon-strated a very high sensitivity of $3.60{\mu}A\;ppm^{-1}$ and an excellent linear response over the concentration range of 100-1000 ppm. Moreover, this electrode was also evaluated in terms of response and recovery times, reproducibility, and long-term stability. Obtained results revealed good sensing performance in hydrogen detection.

Humidity Calibration for a Pressure Gauge Using a Temperature-Stable Quartz Oscillator

  • Suzuki, Atsushi
    • Applied Science and Convergence Technology
    • /
    • v.25 no.6
    • /
    • pp.124-127
    • /
    • 2016
  • Humidity calibration for a temperature-stable quartz oscillator (TSQO) was investigated to exclude the influences of relative humidity on the TSQO output in order to use the corresponding devices outdoors. The TSQO output is a voltage that is inversely proportional to the electric impedance of the quartz oscillator, which depends on the viscosity and density of the measured gas. The TSQO output was humidity calibrated using its humidity dependence, which was obtained by varying the relative humidity (RH) from 0 to 100 RH% while other conditions were kept constant. The humidity dependencies of the TSQO output were fit by a linear function. Subtracting the change in the TSQO output induced by the change in humidity, calculated with the function from the experimentally measured TSQO output for a range of 0-100RH%, eliminated the influence of humidity on the TSQO output. The humidity calibration succeeded in reducing the fluctuations of the TSQO output from 0.4-3% to 0.1-0.3% of the average values for a range of 0-100RH%, at constant temperatures. The necessary stability of the TSQO output for application in hydrogen sensors was below one-third of the change observed for a hydrogen leakage of 1 vol.% hydrogen concentration, corresponding to 0.33% of the change in each background. Therefore, the results in this study indicate that the present humidity calibration effectively suppresses the influence of humidity, for the TSQO output for use as an outdoor hydrogen sensor.

Sensing Properties of Hydrogen Gas for the MWCNT Thin Film Sprayed on the Glass Substrate Cured with Plasma and Nitrocellulose (플라즈마 및 니트로셀롤로우스로 처리된 유리기판을 사용한 MWCNT 스프레이 박막의 수소가스 검출특성)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.290-296
    • /
    • 2011
  • Carbon nanotubes (CNTs) have excellent electrical, chemical stability, mechanical and thermal properties. In this paper, networks of Multi-walled carbon nanotube (MWCNT) materials were investigated as a resistive gas sensors for the $H_2$ gas detection. Sensor films were fabricated by the air spray method using the multi-walled CNTs dispersion solution on the glass substrates cured with plasma and nitrocellulose. Sensors were characterized by the resistance measurements in the self-fabricated oven in order to find the optimum detection properties for the hydrogen gas molecular. The sensitivity and the linearity of the MWVNT sensors using the glass substrate cured with plasma for the $H_2$ gas concentration of 0.06~0.6 ppm are 0.013~0.097%/sec and 0.131~0.959%FS, respectively. The MWCNT film was excellent in the response for the hydrogen gas moleculars and its reaction speed was very fast, which could be using as hydrogen gas sensor. The resistance of the fabricated sensors decreases when the sensors are exposed to $H_2$ gas.

Effects of Pd Nanoparticles on Single-Walled Carbon Nanotubes as High-Sensitivity Hydrogen Gas Sensors (덴드리머와 팔라듐 나노입자를 이용한 단일벽 탄소나노튜브 고성능수소센서)

  • Lee, Jun Min;Ju, Seonghwa;Joe, Jin Hyoun;Kim, Sung-Jin;Lee, Wooyoung
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.4
    • /
    • pp.342-346
    • /
    • 2010
  • Pd nanoparticles (NPs) were successfully functionalizedon the surfaces of single-walled carbon nanotubes (SWNTs) by dendrimer-mediated synthesis. The hydrogen sensing properties of the Pd NPs functionalized SWNTs were investigated. Pd NPs-dendrimer-SWNTs sensors show much better speedsand superior recovery rates but lower sensitivity compared to Pd NPs-functionalized SWNTs directly fabricated due to the existence of dendrimers. Pyrolysis of the dendrimers by heat treatment resulted in a fast response time and high sensitivity owing to the reduced length of the dendrimers. These results demonstrate that the heat treatment of dendrimers in Pd NPs-dendrimer-SWNTs sensors can enable significant electrical conductance modulation upon exposure to extremely low concentrations (10 ppm) of hydrogen gas ($H_2$) in air.

A Study on the Selectivity of Gas Sensors by Sensing Pattern Recognition (감지 패턴 인식에 의한 가스센서의 선택성 연구)

  • Lee, Sung-Pil
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.428-433
    • /
    • 2011
  • We report on the building of a micro sensor array based on typical semiconductor fabrication processes aimed at monitoring selectively a specific gas in ambient of other gases. Chemical sensors can be applied for an electronic nose and/or robots using this technique. Microsensor array was fabricated on the same chip using 0.6${\mu}m$ CMOS technology, and unique gas sensing patterns were obtained by principal component analysis from the array. $SnO_2$/Pt sensor for CO gas showed a high selectivity to buthane gas and humidity. $SnO_2$ sensor for hydrogen gas, however, showed a low selectivity to CO and buthane gas. We can obtain more distinguishable patterns that provide the small sensing deviation(the high seletivity) toward a given analyte in the response space than in the chemical space through the specific parameterization of raw data for chemical image formation.

Electrochemical Detection of Hydrogen Peroxide based on Viologen Monolayers (Viologen 박막을 이용한 과산화수소의 전기화학적 검출 특성)

  • Choi, Won-Suk;Lee, Dong-Yun;Park, Sang-Hyun;Park, Jae-Chul;Kwon, Young-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2006-2010
    • /
    • 2008
  • In this paper, we fabricated a biosensor for detecting hydrogen peroxide and investigated the sensing property. We prepared a viologen and hemoglobin modified gold electrode using self-assembly and layer by layer method. The electrochemical property of the viologen derivative was characterized in 0.1 M $NaClO_4$ electrolyte solution by cyclic voltammetry. The modified electrode showed reversible electrochemical properties and high stability. From the results, the viologen can act as a charge transfer mediator for access to the electrode surface. The catalytic characteristics of the designed sensor proved that hemoglobin has been kept in its natural structure and can retain its biological activity. The designed biosensor showed a fast amperometric response, excellent linearity and low detection limit. In addition, it had high sensitivity, good reproducibility and stability.

PEDOT:PSS and Graphene Oxide Composite Hydrogen Gas Sensor (전도성 고분자 PEDOT:PSS와 산화 그래핀 복합물 수소 가스 센서)

  • Maeng, Sunglyul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.69-73
    • /
    • 2018
  • The power law is very important in gas sensing for the determination of gas concentration. In this study, the resistance of a gas sensor based on poly (3, 4-ethylenedioxythiophene) polystyrene sulfonate+graphene oxide composite was found to exhibit a power law dependence on hydrogen concentration at $150^{\circ}C$. Experiments were carried out in the gas concentration range of 30~180 ppm at which the sensor showed a sensitivity of 6~9% with a response and recovery time of 30s.

Design of a sensor structure for hydrogen sensing at normal temperature operation (상온 작동 수소감지를 위한 센서 구조에 관한 연구)

  • Jeong, Hye-Jeong;Song, Ho-Geun;Boo, Seong-Jae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.777-780
    • /
    • 2009
  • 본 연구에서는 연료전지에의 응용을 위한 저가격의 무산소, 상온동작 가능한 센서구조를 설계, 제작하고 특성을 평가하였다. 연료전지의 수소 농도를 측정하기 위해서는 50ppm에서 5% 이상까지 넓은 범위를 감지할 수 있는 수소센서의 성능이 매우 중요하다. 이러한 특성과 상용화를 위해 가격 경쟁력을 갖는 수소센서로서, 수소흡착에 따른 Pd의 저항변화 특성을 이용한 센서 구조에 대하여 연구하였다. 높은 저항치를 갖는 Pd 후막 구조설계를 통하여 저항 감소형의 센서를 제작하여 특성평가를 하였다. 저가형으로 설계 제작된 Pd 수소센서는 50~20000ppm 범위에서 감지특성을 나타내었으며, 약 40sec의 응답속도를 보였다.

  • PDF