• Title/Summary/Keyword: housing building fire

Search Result 62, Processing Time 0.025 seconds

A Study on the Fire Risk of Urban type housing constructed by pilotis structures, -In the case of Uijeongbu fire- (필로티구조 도시형생활주택의 화재위험성에 관한 연구 -의정부사례를 바탕으로-)

  • Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.50-51
    • /
    • 2017
  • The Urban-type building is an building that it relaxed the construction standard and subsidiary facility standard. The most of the urban-type buildings are pilotis, the main case of representing these building's fire risk is the Uijeongbu fire this study investigated to piloti urban type housing risk on the basis of Uijeongbu fire, and we checked structural problem that unable to escape from the rooftop inside the piloti. also, there was confirmed limit to the evacuation of the occupants because the smoke was rapidly transferred to the top layer through inside the electric duct. and when we analyzed smoke flow use of Fire simulation, it was confirmed Available Safety Egress Time that is four minutes of CO.

  • PDF

A Study on Setting the Grade of Vertical Evacuation Rank to Introduce an USN-based Evacuation System into Super High-rise Apartment Housing's (초고층 공동주택의 USN기반 피난시스템 도입을 위한 수직적 피난위계 설정에 관한 연구)

  • Hong, Won-Hwa;Jeon, Gyu-Yeob;Choi, Jun-Ho
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.133-141
    • /
    • 2007
  • The purpose of this study is to secure an evacuation time and to ensure safety by using an Ubiquitous Sensor Network computing when a fire breaks out at a super high-rise apartment housing. A super high-rise apartment housing that is a type of building to solve the problem of separation of the urban function and the phenomenon of hollowing out downtown has been on the increase, high-rise apartment housings occupying 52.7% of whole housings in 2005. However, if a fire breaks out, there would be serious damage since it accommodates many people and facilities as existence of vertical gigantism in the city. The architectural law in force has no clause on it which is universally applicable to general building, it is difficult to be applicable to a densely super high-rise apartment housing and there would be in danger of a resident's evacuation in the fire. Therefore, as a previous study to introduce an USN-based fire-warning facility and evacuation equipment, this study shows the improvement way after analyzing factors that are barriers to evacuaee's behavior of a super high-rise apartment housing and also shows establishment of the grade of vertical evacuation rank by SimuleX, one of the best computer simulation program.

The Analysis of Evacuation Safety by Smoke Alarm in Housing Fire (주택형화재경보기 작동에 따른 피난안전해석)

  • Choi, Young-Sang;Jeon, Heung-Kyun;Bak, Yeul-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.73-82
    • /
    • 2011
  • This study was performed to analysis the influence of smoke alarm detector on evacuation safety in housing fire. The analysis was conducted by CFAST fire simulation program and building EXODUS evacuation program. The effects of the earlier response time on evacuation safety were investigated by using evacuation simulation program with several steps of different response time and smoke alarm activation time for 4 occupants. The smoke detecter was activated 37.1 second after fire. The first two mortuary were occurred for 170 seconds of response time at the end of living room near exit. But for the 37.1 seconds of response time 4 occupants evacuated safely. From this study, the fire alarm detector is more important for safety evacuation in housing fire.

A Study on the Fire-Safety Design for the Historic Buildings (역사적 건조물의 화재안전을 위한 기초연구)

  • Lee Ji-Hee
    • Journal of the Korean housing association
    • /
    • v.15 no.6
    • /
    • pp.107-113
    • /
    • 2004
  • Fire was and remains a great threat to historic buildings of wood. This threat is omnipresent and often results to irreparable property losses especially cultural heritages. Fire of historic buildings continues to increase every year. The purpose of this study is to preserve a life safety, historical heritage and architectural & cultural values by pursuing for fire safety in the historical buildings. This study shall employ two research methods: a literature review and field survey methods. The literature review shall focus on the observations of characteristics noted in fire codes. The field survey shall cover a heat analysis and fire protection equipment. A method is proposed to investigate fire codes related historical building, reported fire history Fire Codes and Regulations for modern buildings are not always applicable on the historic buildings. Old buildings, and some new buildings with architectural, historical or cultural importance may have values which cannot be measured on a monetary scale. Their protection against the damage caused by fire is considered to be one of the basic moral duties of society. It is strongly recommended, therefore, legislation for fire safety in historical buildings must be extended to a complementary relationship with 'active' fire protection measures, to provide safety in real historical building in real fire situations. The development and application of performance based Codes and the Fire Safety Engineering approach seems to be a rather reasonable and effective way to deal with this historical buildings.

A Study on the Survey of Each Country's Standards to Prevent Flashover of Housing Building (주거시설의 플래시오버 방지를 위한 각국의 내장재 기준 조사에 관한 연구)

  • Hun, Ye-Rim;Kim, Yoon-Seong;Lee, Byeong-Heun;Jin, Seung-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.44-45
    • /
    • 2021
  • In Korea, the risk of fire in buildings is increasing. Therefore, efforts are needed to reduce casualties and property damage. Accordingly, it is important to limit the flashover so that the fire inside the building does not expand to the outside. Flashover refers to the generation of upward airflow after the fire in the compartment, and when combustible gas accumulates in the upper part of the fire chamber and reaches about 500℃, explosive expansion combustion occurs inside the compartment. This can suppress flashover due to limitations on building interior materials. To this end, internal limitations are being implemented at home and abroad through standards related to internal materials. In this paper, we intend to secure basic data on domestic fire safety design by comparing domestic and foreign standards and reviewing the Japanese housing interior design manual.

  • PDF

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

A Study on the Fire Safety Design Methods of Opening in High-rise Building (초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

A Basic Study on the Fire Experiment of a Single Area for Fire Safety Design. (단일구획실험을 통한 화재안전설계에 관한 기초적 연구)

  • Kim, Dong;Yoon, Ung-Gi;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.110-111
    • /
    • 2013
  • This research studies in the field of domestic fires are an issue in many scientific fire research as a research method to validate the domestic environment and ISO-9705 housing on the basis of experiments in virtual space by making a single fire compartment space for conducting experiments and Appearance of a fire occurring within each flammable Heat Release Rate analysis was carried out mainly. Placed within the space of one flammable HRR calculated as the sum of the number of single-room fire experiments conducted and the results compared with the value in comparing the conduct of fire locations and fire load within the building area of the future, the HRR value represents the change in domestic a consideration of the safety of the building is to propose matters.

  • PDF

How Visual-Field Obstruction from Fire Smoke Influences a Resident's Necessary Time to Reach Fire Escape and Evacuation Route in a High-rise Apartment Housing (연기발생으로 인한 시야장애가 초고층 공동주택 거주자의 피난계단실 진입시간과 피난경로에 미치는 영향)

  • Seo, Sang-Mok;Choi, Jun-Ho;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.103-110
    • /
    • 2008
  • The purpose of this study is to know how visual-field obstruction from fire smoke influences a resident's necessary time to reach fire escape and evacuation movement in a high-rise apartment housing. Generally, fire smoke not only gives visual-field obstruction and breath troubles to residents but interrupts their evacuation behavior. If a fire smoke layer is formed in the core department when evacuee enters at the evacuation staircase until, residents will be made to undergo a range of vision obstacle. In order to set a situation like that, participants wore eye bandage which had been made especially before the experiment. Also as a comparative standard, through no.1442 Japanese construction ministry notices about the building evacuation safety verification method, this study calculated smoke layer's dissent time and evacuation time. Then to compare with the former, the participants without an eye bandage joined a experiment once again. This study has understood how fire smoke effects on one's evacuation delay by analyzing residents' evacuation time to reach the staircase and movement route, however, in this study a toxic gas is not considered because it might threaten participants not to breathe.