• Title/Summary/Keyword: hospital use

Search Result 5,845, Processing Time 0.04 seconds

Plasma Levels of High Molecular Weight Adiponectin are Associated with Cardiometabolic Risks in Patients with Hypertension (고혈압 환자에서 혈장 고분자량 아디포넥틴 농도와 심장-대사위험인자와의 관련성 연구)

  • Chung, Hye-Kyung;Shin, Min-Jeong
    • Journal of Nutrition and Health
    • /
    • v.41 no.8
    • /
    • pp.733-741
    • /
    • 2008
  • In the present study, we comprehensively examined the associations of plasma levels of total adiponectin and high molecular weight (HMW) adiponectin with the features of cardiometabolic risks including body fat distribution, dyslipidemia, insulin resistance and inflammatory markers in a cross-sectional study of 110 treated hypertensive patients. Blood lipid profiles, high sensitivity C-reactive protein (hsCRP) and homeostasis model assessment of insulin resistance (HOMA- IR) derived from fasting glucose and insulin concentrations were determined. Plasma levels of tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$), interleukin-6 (IL-6) and intercellular adhesion molecule-1 (ICAM-1) were analyzed using ELISA. The results showed that plasma levels of HMW-adiponectin were negatively associated with body mass index (BMI, r = - 0.203, p < 0.05) and waist circumference (r = -0.307, p < 0.01), which was not shown in total adiponectin. Plasma levels of HMW-adiponectin were negatively associated with triglyceride (r = -0.223, p < 0.05) and positively associated with HDL-cholesterol (r = 0.228, p < 0.05). Plasma levels of adiponectin were positively associated with HDL-cholesterol (r = 0.224, p < 0.05). Plasma levels of HMW-adiponectin were negatively associated with hsCRP (r = -0.276, p < 0.01) and IL-6 (r = -0.272, p < 0.01). In addition, there were weak associations between plasma levels of HMWadiponectin and TNF-${\alpha}$ (r = -0.163, p = 0.07) and ICAM-1 (r = -0.158, p = 0.09). However, there were no significant associations of total adiponectin with inflammatory markers except hsCRP (r = -0.203, p < 0.05). Stepwise multiple linear regression analysis showed that only plasma levels of HMW-adiponectin was an independent factor influencing serum levels of hsCRP, a marker of systemic low grade inflammation, after adjusting for age, gender, BMI, waist circumference, alcohol intake, smoking status, blood lipids, total adiponectin and drug use (p < 0.01). These results suggest that HMW-adiponectin, rather than total adiponectin, is likely to be closely associated with the features of cardiometabolic risks in treated hypertensive patients and might be effective biomarker for the prediction of cardiovascular disease.

Effect of Endothelial Cell Growth Factor and Cyclic AMP Increasers on the Proliferation of Human Omental Microvascular Endothelial Cells (사람의 대망미세혈관내피세포 증식에 대한 내피세포성장인자 및 CYCLIC AMP 증가물질의 효과)

  • Kim, Won-Gon;Kim, Jong-Man;Yu, Se-Yeong
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.463-470
    • /
    • 1995
  • Complete prelining of artificial vascular grafts with autologous endothelial cells may be one of the ideal solutions to obtain a nonthrombogenlc blood-contacting surface. To establish an intact endothelial cell monolayer on a prosthetic surface at the time of implantation,a sufficient number of endothelial cells and adequate propagation condition In cell culture are prerequisites. In this experimental study, endothelial cells from microvessels of adult human oriental adipose tissue were enzymatically harvested, and optimal culture conditions for proliferation of the endothelial cells in cell culture were examined. Human oriental adipose tissue was digested with collagenase and endothelial cells were separated from other stromal elements by mesh filtration method. Cultured cells were identified as endothelial cells by immunofluorescent staining for factor VIII-related antigen. Proliferation in usual 20% fetal bovine serum (FBS) medium or medium containing endothelial cell growth factor (ECGF)(5 ng/ml) and heparin (HEP)(1,000 units/ml) were compared,and the effects of adding compounds that increase intracellular cyclic adenosine monophosphate levels, that is,cholera toxin (CT)(1 $\mu\textrm{g}$/ml) and isobutylmethylxanthine (IBMX)(0.2 ml),were also analyzed. In total,following eight media groups were examined. 1) FBS medium + ECGF + HEP, 2) FBS medium + ECGF + HEP+CT, 3) FBS medium+ECGF+HEP+lBMX, 4) FBS medium+ECGF+HEP+CT+ IBMX, 5) FBSmedium, 6) FBS medium +CT, 7) FBS medium + IBMX, 8) FBS medium + CT + IBMX. It was shown that the medium containing ECGF + HEP with or without cholera toxin was most efficient in Stimulating cell proliferation. IBMX was considered to have antagonistic effect to ECGF. Among experimental groups without ECGF and HEP, the addition of cholera toxin and IBMX was shown to significantly potentiate cell proliferation. This results could provide a practical method for use of cultured human endothelial cells for endothelial cell seeding of cardiovascular prosthetic device, particularly in small-diameter vascular grafts.

  • PDF

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

A retrospective statistical analysis of dental implants (치과 임플란트 환자의 통계 분석에 관한 후향적 연구)

  • Zhao, Chun-Ri;Cho, In-Ho;Moon, Eun-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.266-272
    • /
    • 2009
  • Statement of problem: The number of edentulous patients is increasing due to an aging society, which leads to increased demands and interests on implant restorations. Implant restorations are an effective treatment method for both complete and partially edentulous patients, and the success rate has been reported to be high. But because of the increased use of implants in various situations have resulted in frequent reports of failures on implant restorations. Various efforts to overcome these failures have been made. Purpose: The aim of this study was to investigate the statistic survival rate of dental implants on patients who were treated at Dankook University Dental Hospital during the past 10 years based on their charts. Materials and methods :The research was made for two different periods of time; The first investigation was for patients from August, 1998 to August, 2003 and the second was for patients from September, 2003 to April, 2007. Information on the number of implants placed, the location and distribution of implants, the duration between the first and second surgery, and the survival rate of implants were investigated from the patients'charts. Results: 1. According to the first investigation, 1680 implants were placed on 612 patients and the second investigation showed 2438 implants placed on 933 patients. Thus a total of 4118 implants on 1545 patients. 2. Among the 1545 patients, 884 patients were male (57.2 %) and 661 patients were female (42.8%). Out of 4118 implants, 1739 implants (42.2%) were placed on the maxilla, and 2379 implants (57.8%) on the mandible. Implants were placed most frequently in the posterior region of the mandible. A total of 2043 implants (53.2%) were placed in this region. 3. According to the first investigation, 57 out of 1680, implants failed, while from the second investigation, 17 out of 2438 implants were reported as failure. In total, 74 implants failed, which results in a 98.2% survival rate. 4. The average duration between the first and the second surgeries in maxillas decreased from 7.4 months to 6.8 months. The duration also decreased from 5.6 months to 5.0 months in mandibles. Conclusion: As shown in the results, the number of placed implants and the survival rate of implants were higher in the second investigation than that of the first investigation. And the time spent after the first surgery to the second surgery was less in the second investigation. Consequently, it can be presumed that the demand and consumption of dental implants as well as the survival rate will increase in the future.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

The Etiological Role of Legionella Pneumophila in Patients with Community-Acquired Pneumonia in Korea (입원한 지역사회획득 폐렴 환자에서 요중 레지오넬라항원 검사를 통해 본 Legionella Pneumophila 감염의 비중)

  • Song, Hong-Seok;Suh, Ji-Hyeon;Ahn, Jong-Ho;Yoon, Byeong-In;Lee, Seung-Joon;Lee, Myung-Goo;Jun, Man-Jo;Kang, Min-Jong;Lee, Jae-Myung;Kim, Dong-Gyu;Son, Jee-Woong;Park, Myung-Jae;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.409-414
    • /
    • 2001
  • Background : Legionella pneumophila has been recognized as an important cause of community-acquired pneumonia(CAP) requiring hospitalization. However, epidemiological data on the occurrence of legionella-related pneumonia is unavailable in Korea. The purpose of this study was to evaluate the etiological importance of legionella pneumophila serogroup 1 in patients hospitalized with CAP. Method : The CAP patients over 16 year-old were recruited from July 1999 to June 2000 at the Chunchon Sacred Heart Hospital. Fifty four patients (male 29, female 25, average age $63.8{\pm}15.3$) were included in this study. A diagnosis of a legionella pneumophila infection was based on a urinary antigen test using the Binax Company enzyme immunoassay. The severity of pneumonia was assessed using the Fine's PORT scoring system. Result : The average Fine's PORT score was 99.7(${\pm}44.9$). According to the risk classification proposed by the Infectious Disease Society of America, the number of patients in each class(from class I to class V) were 6(11.1%), 13(24.1%), 9(16.7%), 14(25.8%), and 12(22.2%), respectively. Thirty two patients(59.3%) were initially admitted to the intensive care unit. The mortality rate was 16.7%(9 in 54). In all patients, urinary antigens to Legionella pnewnophila serogroup 1 were not detected. Conclusion : Legionella pnewnophila may play little role in causing adult CAP in Korea. Therefore, the routine use of macrolide in the empirical treatment of the CAP patients based upon the ATS guidelines(1993) in Korea should be reevaluated.

  • PDF

The Effect of Inhibition of Heme Oxygenase-1 on Chemosensitivity of Cisplatin in Lung Cancer Cells (폐암세포주에서 Heme Oxygenase-1의 억제가 Cisplatin의 항암제 감수성에 미치는 영향)

  • Kim, So-Young;Kim, Eun-Jung;Jang, Hye-Yeon;Hwang, Ki-Eun;Park, Jung-Hyun;Kim, Hwi-Jung;Jo, Hyang-Jeong;Yang, Sei-Hoon;Jeong, Eun-Taik;Kim, Hak-Ryul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.33-42
    • /
    • 2007
  • Background: Heme oxygenase-1 (HO-1) is known to modulates the cellular functions, including cell proliferation and apoptosis. It is known that a high level of HO-1 expression is found in many tumors, and HO-1 plays an important role in rapid tumor growth on account of its antioxidant and antiapoptotic effects. Cisplatin is a widely used anti-cancer agent for the treatment of lung cancer. However, the development of resistance to cisplatin is a major obstacle to its use in clinical treatment. We previously demonstrated that inhibiting HO-1 expression through the transcriptional activation of Nrf2 induces apoptosis in A549 cells. The aim of this study was to determine of the inhibiting HO-1 enhance the chemosensitivity of A549 cells to cisplatin. Materials and Methods: The human lung cancer cell line, A549, was treated cisplatin, and the cell viability was measured by a MTT assay. The change in HO-1, Nrf2, and MAPK expression after the cisplatin treatment was examined by Western blotting. HO-1 inhibition was suppressed by ZnPP, which is a specific pharmacologic inhibitor of HO activity, and small interfering RNA (siRNA). Flow cytometry analysis and Western blot were performed in to determine the level of apoptosis. The level of hydrogen peroxide ($H_2O_2$) generation was monitored fluoimetrically using 2',7'-dichlorofluorescein diacetate. Results: The A549 cells showed more resistance to the cisplatin treatment than the other cell lines examined, whereas cisplatin increased the expression of HO-1 and Nrf2, as well as the phosphorylation of MAPK in a time-dependent fashion. Inhibitors of the MAPK pathway blocked the induction of HO-1 and Nrf2 by the cisplatin treatment in A549 cells. In addition, the cisplatin-treated A549 cells transfected with dither the HO-1 small interfering RNA (siRNA) or ZnPP, specific HO-1 inhibitor, showed in a more significantly decrease in viability than the cisplatin-only-treated group. The combination treatment of ZnPP and cisplatin caused in a marked increase in the ROS generation and a decrease in the HO-1 expression. Conclusion: Cisplatin increases the expression of HO-1, probably through the MAPK-Nrf2 pathway, and the inhibition of HO-1 enhances the chemosensitivity of A549 cells to cisplatin.

Three dimensional analysis of tooth movement using different sizes of NiTi wire on NiTi scissors-bite corrector (NiTi scissors-bite corrector의 와이어 굵기에 따른 3차원적 치아 이동 양상)

  • Jeon, Hyun-Ju;Park, Sun-Hyung;Jung, Sang-Hyuk;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • Objective: The purpose of this study was to compare the difference in three dimensional tooth movement using three different wire sizes($0.018{\times}0.025-in,\;0.016{\times}0.022-in$ 0.016-in) on a NiTi scissors-bite corrector. Methods: Computed tomography(CT) images of the experimental model before and after tooth movement were taken and reconstructed into three dimensional models for superimposition. The direction and the amount of tooth movement were measured and analyzed statistically. Results: The lingual and intrusive movements of the crown of the maxillary second molar were increased as the size of the NiTi wire increased. The roots of the maxillary second metals moved buccally except for the 0.016-in group. The intrusive movement of the roots of the maxillary second molars was increased as the size of the NiTi wire increased. Due to the use of orthodontic mini-implants, anchorage loss was under 0.2 mm on average. Conclusions: The $0.018{\times}0.025-in$ NiTi wire was most effective in lingual and intrusive movement of the maxillary second molar which was in scissors-bite position. Indirect skeletal anchorage with a single orthodontic mini-implant was rigid enough to prevent anchorage loss.

A Study on Dental Hygienists' Health Management and Their Use of Medical Care Services (치과위생사의 건강관리 및 의료 이용 행태에 관한 조사 연구)

  • Yoon, Mi-Sook;Lee, Kyung-Hee
    • Journal of dental hygiene science
    • /
    • v.4 no.1
    • /
    • pp.13-20
    • /
    • 2004
  • The purpose of this study was to examine how dental hygienists health management and to what extent they used medical care services due to occupational diseases. It's ultimately attempted to improve the health care of dental hygienists and promote their health. After relevant literature and data were reviewed, a survey was conducted for five months from June through October, 2003. The subjects in this study were 160 dental hygienists who worked at dental hospital and clinics across the nation. And the collected data were analyzed. The findings of this study were as follows: (1) Concerning job-related health education experience, 83.1 percent, the greatest rate, had no experience to receive education, and the type of service made a significance difference to that(p<0.05). (2) As to in-house medical examination, 98.6 percent felt the need for medical examination, and 56.3 percent had ever their bodies examined. Their health examination experience was significantly different according to age(p<0.01), marital status(p<0.01), type of service(p<0.01), career(p<0.01) and yearly income(p<0.01). (3) Concerning how much they used hospitals after working as dental hygienists, 85.6 percent, the biggest group, had no experience to be hospitalized, and that was significantly different according to age(p<0.05), type of service(p<0.05), career(p<0.01) and yearly income(p<0.05). 51.9 percent had no experience to receive treatment as outpatients, and their career(p<0.01) made a significant difference to that. (4) As for how to cope with casual diseases, 34.4 percent, the largest group, visited pharmacies, and 32.5 percent, the next largest group, saw the doctors. In regard to herb restorative, 68.1 percent had no experience to take herb restorative, and that experience varied significantly with age(p<0.01), career(p<0.05) and annual income(p<0.01).

  • PDF