• Title/Summary/Keyword: horizontal reference plane

Search Result 63, Processing Time 0.03 seconds

A study of sagittal condylar inclination and occlusal plane inclination of two semiadjustablearticulators with different reference plane (기준면이 다른 반조절성 교합기의 전방시상과로각과 교합평면경사각에 대한 연구)

  • Kim, Hyo-Jung;Lee, Sung-Bok;Choi, Dae-Gyun;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.420-430
    • /
    • 2008
  • Statement of problem & Purpose: Articulators are very important for education and overall clinical situation in the field of prosthodontics, however preexisting articulators are designed and built based on maxillofacial structures and mean values of mandibular movement of Western people. Purpose of this research is to find out a adequate basis for applicating these articulators, presently used for clinical education, for Korean. Material and methods: 59 Korean adults (41 males, 18 females), aged between 24 to 41, where selected for this study. Two pairs of both maxillary and mandibular models were made for each examinee. These models where attached to both KaVo PROTARevo 7 and Hanau Modular semiadjustable articulators by using facebow transfer, than sagittal condylar inclination, occlusal plane inclination and position of mandibular on the articulator where measured. Result and conclusion: 1. Mean sagittal condylar inclination for KaVo PROTAR semiadjustable articulator was $33.75^{\circ}$(standard deviation $12.46^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $40.72^{\circ}$(standard deviation $12.09^{\circ}$) for mean sagittal condylar inclination. 2. Mean occlusal plane inclination for KaVo PROTAR semiadjustable articulator was $-2.76{\circ}$(standard deviation $3.63^{\circ}$) meanwhile Hanau Modular semiadjustable articulator showed $11.87^{\circ}$ (standard deviation $3.63^{\circ}$) for mean occlusal plane inclination. 3. On the average center of the mandibular dentition were in the range of 5 to 7 mm of the central position of the articulator. Both anterior and posterior dentition were positioned at the center of the articulator vernacularly for KaVo PROTAR semiadjustable articulators, meantime for Hanau Modular semiadjustable articulator, anterior dentition was positioned 5 mm downwards and 3mm upwards for posterior dentition from vertically central position of the articulator.

Skeletodental changes during treatment and retention in Class II division 1 malocclusion (II급 부정교합의 치료와 유지시 골격치성요소의 변화)

  • Kim, Sang-Cheol;Kim, Sun-Young
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.687-698
    • /
    • 2000
  • The purpose of this study was to evaluate the changes of skeletodental patterns during Class II treatment and its retention period. Forty two patients of Class II malocclusion, which was treated with nonextraction or first premolar-extraction were selected and their lateral cephalograms were examined in this study. Various skeletodental changes in lateral cephalograms of pre-treatment, post-treatment and retention were measured by superimposition in reference to the cranial base for jaws, the palatal plane for maxillary teeth, and mandibular plane for mandibular teeth. The data were analyzed by paired t-test. In this study, occlusal plane showed the significant anterior downward steepening after active treatment, and remained during retention period. In the nonextraction group, maxillary incisors were retracted and extruded during treatment. Maxillary molars were extended, and mandibular molar were uprighted, with no mesial movement. In the extraction group, both maxillary and mandibular incisors were retracted and extruded. Maxillary molars were extruded and moved mesially, and mandibular molars were extruded and moved mesially with no mesial tilting. During retention period in both groups, there were tendencies of labial tipping of maxillary incisor, and mesial tipping of maxillary and mandibular molar. But the changes were not significant and most of teeth showed no change in vortical and horizontal direction.

  • PDF

Implementation on the Portable Blood Gas Analyzer and Performance Estimation/A Study on the Hydrometer Calibration System using Image Processing (영상처리 기법을 이용한 부액계 자동 교정 시스템 구현)

  • Lee, Yong-Jae;Chang, Kyung-Ho;Oh, Chae-Youn;Jung, Sang-Duk
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.258-264
    • /
    • 2003
  • The present paper studies how to calibrate hydrometer using image process. The method aligns particular scales of hydrometer selected for calibrating the hydrometer with the horizontal plane of the reference liquid automatically without man's operation. Major parts composing the system are CCD camera, frame grabber, stepping motor and image process program. The image process program is composed of a part that locates the meniscus and aligns it with a scale and a part that controls the step motor. To verify the performance of the developed method, this study compares the meniscus and scale observed directly with the naked eye with the result of calibration by the manual calibration method. The differences between the corrections were less than $0.004\;kg/m^3$ with uncertainty of $0.06\;kg/m^3$. These showed that the calibration results of the developed hydrometer calibration using image process nearly equal to manual method.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

Assessment of antero-posterior skeletal relationships in adult Korean patients in the natural head position and centric relation (자연 두부 위치 및 안정위에서 한국 성인 환자 골격의 전.후 관계 결정)

  • Ahn, Jang-Hoon;Bae, Kwang-Hak;Park, Young-Ju;Hong, Ryoon-Ki;Nam, Joeng-Hun;Kim, Mi-Ja
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.421-431
    • /
    • 2010
  • Objective: This study aimed to verify the intra-individual reproducibility of the natural head position (NHP) in adult Korean patients in the centric relation (CR) position and to prove the inter-individual variability of the Frankfurt horizontal (FH) plane and sella-nasion (SN) line compared to the true horizontal line (THL). In addition, the study aimed to investigate the correlations between linear measurements from A-point and B-point to the nasion true vertical line (NTVL) and angular measurements from A-point and B-point to the SN line. Methods: Two lateral cephalograms were taken of 116 subjects (23 males, 93 females) with CR wax bites in a NHP at a one-week interval. Results: Method errors of three variables and intraclass correlation coefficients of six parameters proved the intra-individual reproducibility of NHP (p < 0.001). The angle of the FH to the THL was not significantly different from $0^{\circ}$ (p > 0.05), but it was clinically variable (SD $3.89^{\circ}$) on the inter-individual level. Conversely, the angle of the SN line to the THL was significantly different from $7^{\circ}$ (p < 0.05). Very low correlation was found between the linear measurements and angular measurements of A-point and B-point (p < 0.01). Conclusions: The NTVL could be a useful reference line for assessing the antero-posterior position of the maxilla and mandible of Korean adult patients in NHP and CR.

A study on the position of tongue and hyoid bone in relation to vertical facial patterns in skeletal Class III malocclusion (골격성 III급 부정교합에서 수직적 안모형태에 따른 혀와 설골의 위치 비교)

  • Woo, Kwang-Su;Yoon, Jeong-Hyun;Kim, Sang-Cheol;Moon, Seong-cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.579-589
    • /
    • 2000
  • The purpose of this study was to evaluate the position of tongue and hyoid bone in relation to vortical facial patterns in the adult and child. Lateral cephalograms taken in adults(63 cases, 11.7 years in average age) and children(69 cases, 22.6 years in average age) were traced and measured about position and posture of tongue and hyoid bone using the horizontal and vertical reference lines. The angle of mandibular plane to SN Plane was employed to classify the samples into groups of hypodivergent and hyperdivergent. The comparison of the tongue/hyoid bone measurements between hypodivergent group and hyperdivergent group in the adult and child were statistically executed with Student's f-test. The results were as follows, 1. The tongue height was lower in the hyperdivergent group than in hypodivergent group, and higher in children than in adults. 2. The vertical height of hyoid bone was higher in hypodivergent group than in hyperdivergent group and also higher in children than in adults. 3. The anteroposterior position was of no significant difference in relation to age or vortical facial pattern. 4. The inclination of hyoid bone in relation to cranial base was steeper in children than in adults.

  • PDF

A Design of Fractional Motion Estimation Engine with 4×4 Block Unit of Interpolator & SAD Tree for 8K UHD H.264/AVC Encoder (8K UHD(7680×4320) H.264/AVC 부호화기를 위한 4×4블럭단위 보간 필터 및 SAD트리 기반 부화소 움직임 추정 엔진 설계)

  • Lee, Kyung-Ho;Kong, Jin-Hyeung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.145-155
    • /
    • 2013
  • In this paper, we proposed a $4{\times}4$ block parallel architecture of interpolation for high-performance H.264/AVC Fractional Motion Estimation in 8K UHD($7680{\times}4320$) video real time processing. To improve throughput, we design $4{\times}4$ block parallel interpolation. For supplying the $10{\times}10$ reference data for interpolation, we design 2D cache buffer which consists of the $10{\times}10$ memory arrays. We minimize redundant storage of the reference pixel by applying the Search Area Stripe Reuse scheme(SASR), and implement high-speed plane interpolator with 3-stage pipeline(Horizontal Vertical 1/2 interpolation, Diagonal 1/2 interpolation, 1/4 interpolation). The proposed architecture was simulated in 0.13um standard cell library. The gate count is 436.5Kgates. The proposed H.264/AVC Fractional Motion Estimation can support 8K UHD at 30 frames per second by running at 187MHz.

VRS-based Precision Positioning using Civilian GPS Code Measurements (가상기준점 기반 코드신호를 이용한 정밀 측위)

  • Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.2
    • /
    • pp.201-208
    • /
    • 2011
  • With the increase in the number of smartphone users, precise 3D positional information is required by various applications. The positioning accuracy using civilian single-frequency pseudoranges is at the level of 10 m or so, but most applications these days are asking for a sub-meter level Therefore, instead of an absolute positioning technique, the VRS-based differential approach is applied along with the correction of the double-differenced (DD) residual errors using FKP (Flachen-Korrektur-Parameter). The VRS (Virual Reference Station) is located close to the rover, and the measurements are generated by correcting the geometrical distance to those of the master reference station. Since the unmodeled errors are generally proportional to the length of the baselines, the correction parameters are estimated by fitting a plane to the DD pseudorange errors of the CORS network. The DD positioning accuracy using 24 hours of C/A code measurements provides the RMS errors of 37 cm, 28 cm for latitudinal and longitudinal direction, respectively, and 76 cm for height. The accuracy of the horizontal components is within ${\pm}0.5m$ for about 90% of total epochs, and in particular the biases are significantly decreased to the level of 2-3 cm due to the network-based error modeling. Consequently, it is possible to consistently achieve a sub-meter level accuracy from the single-frequency pseudoranges using the VRS and double-differenced error modeling.

A Design of 4×4 Block Parallel Interpolation Motion Compensation Architecture for 4K UHD H.264/AVC Decoder (4K UHD급 H.264/AVC 복호화기를 위한 4×4 블록 병렬 보간 움직임보상기 아키텍처 설계)

  • Lee, Kyung-Ho;Kong, Jin-Hyeung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.102-111
    • /
    • 2013
  • In this paper, we proposed a $4{\times}4$ block parallel architecture of interpolation for high-performance H.264/AVC Motion Compensation in 4K UHD($3840{\times}2160$) video real time processing. To improve throughput, we design $4{\times}4$ block parallel interpolation. For supplying the $9{\times}9$ reference data for interpolation, we design 2D cache buffer which consists of the $9{\times}9$ memory arrays. We minimize redundant storage of the reference pixel by applying the Search Area Stripe Reuse scheme(SASR), and implement high-speed plane interpolator with 3-stage pipeline(Horizontal Vertical 1/2 interpolation, Diagonal 1/2 interpolation, 1/4 interpolation). The proposed architecture was simulated in 0.13um standard cell library. The maximum operation frequency is 150MHz. The gate count is 161Kgates. The proposed H.264/AVC Motion Compensation can support 4K UHD at 72 frames per second by running at 150MHz.

A Study on the labial & buccal surface contour in Korean permanent teeth using three-dimensional laser scanning (3차원 레이저 스캐너를 이용한 한국인 영구치의 순, 협측 치관 굴곡도에 관한 연구)

  • Ko, Sang-Duck;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.275-291
    • /
    • 2002
  • Of various factors indicated for effective use of straight wire appliances, there was a great lack of studies both domestic and international about the curvatures of tooth crowns. This study was performed to investigate the labio/buccal clinical crown curvatures of Korean permanent teeth. For this study, three-dimensional laser scanning was performed on 36 dental casts with normal anatomic structures. Andrews plane and Facial axis of clinical crown (FACC) were designated as horizontal and vertical reference planes respectively. 2 or 3 lines, 1mm apart, were drawn superior, inferior, left and right of these reference planes. A three-dimensional coordinate table was made for points formed by crossing these lines, and averages of each coordinate point on the 36 dental casts were obtained. The curvature equation was made using three-dimensional coordinate points (x,y,z) and by this curvature equation, the curve ratio of each tooth was obtained. Curve ratio changes of each section of teeth were calculated by curve ratios of simplified curves. These two dimensional curves were simplified horizontally and vertically Conclusions for this study are as follows. 1. The basic data of labial and buccal clinical crown curvatures were obtained about Korean permanent teeth. 2. No significant difference was found between male and females. 3. Individual tooth characteristics 1) In maxillary central incisors, the difference in the curve ratio between the gingival and incisal sides was greater than for the other teeth. And the gingival side showed a greater curve ratio. 2) Maxillary canines showed more curvatures in the mesio-occlusal surface than the other surfaces. 3) In maxillary $1^{st}$ premolars, more curvatures were found in mesio-occlusal and disto-gingival surface, thus showing a twisted crown surface, but in maxillary $2^{nd}$ premolars, the crown curvatures of mesial and distal ends became parallel to each other. 4) No significant difference in crown curvatures was found between mandibular central and lateral incisors. 5) Occluso-gingival curvatures of mandibular$2^{nd}$ premolar turned out to be more rounded than mandibular $1^{st}$ premolars or maxillary $2^{nd}$ premolars. From the above conclusions, it can be deduced that the same bracket bases can be used for mandibular central and lateral incisors. But for maxillary $1^{st}\;and\;2^{nd}$ premolars and for mandibular $1^{st}\;and\;2^{nd}$ premolars, because crown curvatures showed significant differences, when making bracket bases there is ample reason to make bracket base curves differently for each type of tooth.