• Title/Summary/Keyword: holographic

Search Result 822, Processing Time 0.025 seconds

Bit Error Reduction for Holographic Data Storage System Using Subclustering (서브클러스터링을 이용한 홀로그래픽 정보저장 시스템의 비트 에러 보정 기법)

  • Kim, Sang-Hoon;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time. Today any data storage system cannot satisfy these conditions, however holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System can be constructed without mechanical actuating part so fast data transfer rate and high storage capacity about 1Tb/cm3 can be realized. In this research, to correct errors of binary data stored in holographic data storage system, a new method for reduction errors is suggested. First, find cluster centers using subtractive clustering algorithm then reduce intensities of pixels around cluster centers. By using this error reduction method following results are obtained ; the effect of Inter Pixel Interference noise in the holographic data storage system is decreased and the intensity profile of data page becomes uniform therefore the better data storage system can be constructed.

Real Time Tilt Servo Control of The Holographic Data Storage System (홀로그래픽 정보 저장 장치에서의 실시간 틸트 서보 제어)

  • Moon, Jae-Hee;Kim, Sang-Hoon;Yang, Jun-Ho;Yang, Hyun-Seok;Park, No-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • The purpose of this paper is real time tilt servo control of the holographic data storage system. Holographic data storage device is a next generation data storage device with high storage density, high transfer rate and short access time. This device is very sensitive to a disturbance due to the enormous storage density. As to the recording material changed disc type, the media continuously vibrates as the disc rotates. When disc rotates, deviation, eccentricity and unbalance disturbance are occurred. This disturbances cause disc tilt, finally reference beam does not illuminates to correct incidence angle. Therefore real time tilt servo control is essential. In this paper, the algorithm is proposed to make real time tilt detection in angle multiplexing of the holographic data storage system with an additional servo beam and the experiments are performed.

  • PDF

Fabrication of 2-D photonic crystal with holographic lithography (홀로그램피 리소그래피 방법을 이용한 2차원 포토닉 크리스탈 제작)

  • Ju, Long-Yun;Nam, Ki-Hyun;Kim, Hyun-Koo;Choi, Hyuk;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.162-163
    • /
    • 2007
  • In this paper, we fabrication of 2-D photonic crytal using holographic lithography. We used Ag doped chalcogenide AsGeSeS film and He-Ne (632.8nm) (P:P) Polarized laser beam. The thickness of Ag thin film was varied from 60nm and the thickness of chalcogenide thin film was varied from 2um. Frist, holographic lithography with 1-D photonic crystal on Ag/AsGeSeS film. And than revolved the sample $90^{\circ}$ to fabricate 2-D photonic crystal with holographic lithography.

  • PDF

Measurement of Thermal Flow in a Hele-Shaw Convection Cell Using Holographic Interferometry and PIV Technique (홀로그래픽 간섭계와 PIV를 이용한 Hele-Shaw Convection Cell 내부 열유동 해석)

  • Kim Seok;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.35-38
    • /
    • 2002
  • Variations of temperature and velocity fields in a Hele-Shaw Convection Cell (HSC) were measured using a holographic interferometry and PIV technique with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. PIV results show that flow inside the HSC is periodic and the oscillating state is well matched with the temperature field results. The holographic interferometry and PIV techniques employed in this study are useful for analyzing the unsteady convective thermal fluid flows.

  • PDF

Visual perception of Fourier rainbow holographic display

  • Choo, Hyon-Gon;Chlipala, Maksymilian;Kozacki, Tomasz
    • ETRI Journal
    • /
    • v.41 no.1
    • /
    • pp.42-51
    • /
    • 2019
  • The rainbow hologram provides views of reconstruction with rainbow color within a large viewing zone. In our recent paper, a Fourier rainbow holographic display using diffraction grating and a white-light LED source was introduced. In this technique, the rainbow effect is realized by the dispersion of white-light source on diffraction grating, while the slit is implemented numerically by reducing the demands of the space-bandwidth product of the display. This paper presents a novel analysis on the visual perception of the Fourier rainbow holographic display using Wigner distribution. The view-dependent appearance of the image, including multispectral field of view and viewing zone, is investigated considering the observer and the display parameters. The resolution of the holographic view is also investigated. For this, a new quantitative assessment for image blur is introduced using Wigner distribution analysis. The analysis is supported with numerical simulations and experimentally captured optical reconstructions for the holograms of the computer model and real object generated with different slit size, reconstruction distance, and different observation conditions.

The Measurment Method of Small Deformation by using Holographic Interferometry (홀로그래픽 간섭법을 이용한 미소변형 측정법)

  • Kang, Young-June;Moon, Sang-Joon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.9
    • /
    • pp.52-58
    • /
    • 1995
  • Conventional measurement methods for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been performed as the methods of contact with objects to be inspect, but those methods have been taken relatively much time to be inspected. Holographic interferometry which is a non-contact optical measurement method using a coherent light can overcome these demerit, and also has an advantage that the quantitative measurement of small deformation for large areas can be accomplished at a time with high precision. In this paper the comparisons of the experimental results form holographic interferometry with those from the finite element method(FEM) and the analytical solutions of the elastic equation are discussed.

  • PDF

The Analysis on the Error of Diverging Beam and Cylindrical Surface in Holographic Interferometer for Measuring out-of-plane Displacement. (면외변위 측정을 위한 홀로그래피 간섭게에서 발산빔과 원통표면에 대한 오차해석)

  • Kang, Young-June;Moon, Sang-Joon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.6
    • /
    • pp.128-134
    • /
    • 1997
  • Holographic interferometry is a useful whole-field nondestructive tesing method for measuring deformations and vibrations of engineering structure. In practical way most holographic interferometer uses a diverging beam, a point light source. When an oject is relatively small, the optical arrangement using a collimated light source has no difficulty technically but for a large object the collimated beam connot be applied anymore practically. In this paper we calculate the error of measured displacement from the sensi- tivity vector dominated by the geometry of optical arrangement for holographic interferometer and show the result with 2-D plots. A plane surface and a cylindrical surface were chosen as objects to be measured and the results from the cases of a diverging and a collimated beams were compared and analyzed.

  • PDF

Inverse-Directed Propagation-Based Hexagonal Hogel Sampling for Holographic Stereogram Printing System

  • Anar Khuderchuluun;Munkh-Uchral Erdenebat;Erkhembaatar Dashdavaa;Ki-Chul Kwon;Jong-Rae Jeong;Nam Kim
    • Journal of Web Engineering
    • /
    • v.21 no.4
    • /
    • pp.1225-1238
    • /
    • 2022
  • Holographic stereogram (HS) printing is a promising holographic technique for three-dimensional (3D) visualization of an object with accurate depth cues. In this paper, unlike the conventional rectangular hogel based HS, efficient hexagonal hogels sampling for HS printing that enhances the volumetric visualization of reconstruction while providing rapidly generated data using inverse-directed propagation (IDP) is proposed. Specifically, an array of hexagonal hogels is sampled by a computer-generated integral imaging technique using an IDP, which acquires the full information of the 3D object prior to higher volumetric 3D reconstruction. To demonstrate the proposed approach, IDP-based hexagonal hogel sampling for HS printing is implemented, and the enhanced image quality of printed holograms is verified both by numerical simulation and in an optical experiment.

5 Axis Picomotor Control for Pixel matching in Holographic Data Storage (홀로그래픽 저장장치의 픽셀 매칭을 위한 5 축 피코모터 제어)

  • Lee Jae-Seung;Choi Jin-Young;Yang Hyun-Seok;Park Young-Pil
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1099-1102
    • /
    • 2005
  • In this paper, a new visual servo method, which uses 5 axis picomotor to compensate the misalignment generated between a SLM and a CCD in a holographic storage device, was proposed and the effectiveness of it was proved by the experiment. In a holographic storage device, the data processing is done by the SLM and the CCD, and the shape of data is 2 dimensional binary patterns. Therefore, the exact image matching between the SLM and the CCD is very important, and the mismatching of it causes the errors in the data reconstruction. First, the brief introduction of a holographic data storage is given, then, BER concept which is errors caused by pixel mismatch between the SLM and the CCD is defined. Second, the geometric relation between 5 axis picomotor and the CCD movement is studied. Finally, the visual servo method using 5 axis picomotor to reduce the BER in a holographic storage device is proposed and experimented. From the experiment, we find that about 3% BER improvement is obtained by the proposed method.

  • PDF

Holographic grating formation in AsGeSeS(10,20,40,80nm) thin films (AsGeSeS(10,20,40,80nm) 박막에서의 홀로그래픽 격자 형성)

  • Lee, Ki-Nam;Yoo, Chul-Ho;Kim, Jong-Bin;Lee, Yeong-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.119-122
    • /
    • 2004
  • This paper discovers that we form holographic grating in AsGeSeS thin film. Holographic grating is not developed in the length of 10,20,40nm, while it is formed in the thin film of 80nm though it shows very low diffraction efficiency. On the contrary, holographic grating is established in every thin film of Ag(10nm)/AsGeSeS(10,20,40,80nm). Lattice in 10,20 nm thin film builds up, and immediately disappears. In the case of 40nm thin film, even if holographic grating is made up, it seems to have a low diffraction efficiency. Apart from 10,20,40nm, it shows the highest diffraction efficiency in the thin film of 80nm.

  • PDF