• 제목/요약/키워드: higher heating value

Search Result 345, Processing Time 0.032 seconds

Hydrotreating for Stabilization of Bio-oil Mixture over Ni-based Bimetallic Catalysts (Ni계 이원금속 촉매에 의한 혼합 바이오오일의 안정화를 위한 수소첨가 반응)

  • Lee, Seong Chan;Zuo, Hao;Woo, Hee Chul
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.69-78
    • /
    • 2021
  • Vegetable oils, such as palm oil and cashew nut shell liquid (CNSL), are used as major raw materials for bio-diesel in transportation and bio-heavy oil in power generation in South Korea. However, due to the high unsaturation degree caused by hydrocarbon double bonds and a high content of oxygen originating from the presence of carboxylic acid, the range of applications as fuel oil is limited. In this study, hydrotreating to saturate unsaturated hydrocarbons and remove oxygen in mixed bio-oil containing 1/1 v/v% palm oil and CNSL on monometallic catalysts (Ni and Cu) and bimetallic catalysts (Ni-Zn, Ni-Fe, Ni-Cu Ni-Co, Ni-Pd, and Ni-Pt) was perform under mild conditions (T = 250 ~ 400 ℃, P = 5 ~ 80 bar and LHSV = 1 h-1). The addition of noble metals and transition metals to Ni showed synergistic effects to improve both hydrogenation (HYD) and hydrodeoxygenation (HDO) activities. The most promising catalyst was Ni-Cu/��-Al2O3, and in the wide range of the Ni/Cu atomic ratio of 9/1~1/4, the conversion for HYD and HDO reactions of the catalysts were 90-93% and 95-99%, respectively. The tendency to exhibit almost constant reaction activity in these catalysts of different Ni/Cu atomic ratios implies a typical structure-insensitive reaction. The refined bio-oil produced by hydrotreating (HDY and HDO) had significantly lower iodine value, acid value, and kinetic viscosity than the raw bio-oil and the higher heating value (HHV) was increased by about 10%.

Processing and Mechanical Properties of Mullite Fiber / Fe Composite

  • Niibo, Yoshihide;Yuchi, Kazuhiro;Sameshima, Soichiro;Hirata, Yoshihiro
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 2000.06a
    • /
    • pp.195-214
    • /
    • 2000
  • The high-speed steel (shorten as HSS) consists of Fe and several kinds of transition metal carbides. The cutting tools or wear-resistant materials made from HSS experience relatively high thermal shock because a coolant such as water or oil is flowed over the surface of heated HSS. The purpose of this research is to increase the hardness, strength, fracture toughness and thermal shock resistance of HSS. A possible strategy is to incorporate a hard ceramic material with high strength in HSS matrix. This paper describes the processing, microstructure and mechanical properties of the oriented unidirectional mullite fiber/HSS composite. The unidirectional mullite fibers of 10${\mu}{\textrm}{m}$ diameter were dispersed by the ultrasonic irradiation of 38 kHz in an ethylenglycol suspension containing HSS powder of 11${\mu}{\textrm}{m}$ median size. The dried green composites with 4-68 vol% fibers were hot-pressed for 2h at 100$0^{\circ}C$ in Ar atmosphere under a pressure of 39 MPa. The higher density was achieved in the composite with a lower content of fibers. The oriented unidirectional fibers were well dispersed in the HSS matrix. The average distance between the center of fibers in the cross section was close to the value calculated from the fiber fraction. No reaction occurred at the interfaces between HSS and mullite fibers in the composites. The composite with 13.6 vol% fibers showed 100 MPa of four point flexural strength at room temperature. The thermal expansion of composite with heating was influenced by the orientation of mullite fibers.

  • PDF

Overall Performance characteristic for 300MW Taean IGCC Plant (300MW 태안 IGCC 플랜트 종합성능 특성)

  • Kim, Hakyong;Kim, Jaehwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.129.2-129.2
    • /
    • 2010
  • As a part of the government renewable energy policy, KOWEPO is constructing 300MW IGCC plant in Taean. IGCC plant consists of gasification block, air separation unit and power block, which performance test is separately conducted. Overall performance test for IGCC plant is peformed to comply with ASME PTC 46. Major factors affected on the overall efficiency for IGCC plant are external conditions, each block performance(gasification, ASU, power block), water/steam integration and air integration. Performance parameters of IGCC plant are cold gas efficiency, oxygen consumption, sensible heat recovery of syngas cooler for gasification block and purity of oxygen, flow amount of oxygen and nitrogen, power consumption for air separation unit and steam/water integration among the each block. The gas turbine capacity applied to the IGCC plant is 20 percent higher than NGCC gas turbine due to the low caloric heating value of syngas, therefor it is possible to utilize air integration between gas turbine and air separation unit to improve overall efficiency of the IGCC plant and there is a little impact on the ambient condition. It is very important to optimize the air integration design with consideration to the optimized integration ratio and the reliable operation. Optimized steam/water integration between power block and gasification block can improve overall efficiency of IGCC plant where the optimized heat recovery from gasification block should be considered. Finally, It is possibile to achieve the target efficiency above 42 percent(HHV, Net) for 300MW Taean IGCC plant by optimized design and integration.

  • PDF

One-step microwave synthesis of magnetic biochars with sorption properties

  • Zubrik, Anton;Matik, Marek;Lovas, Michal;Stefusova, Katarina;Dankova, Zuzana;Hredzak, Slavomir;Vaclavikova, Miroslava;Bendek, Frantisek;Briancin, Jaroslav;Machala, Libor;Pechousek, Jiri
    • Carbon letters
    • /
    • v.26
    • /
    • pp.31-42
    • /
    • 2018
  • Adsorption is one of the best methods for wastewater purification. The fact that water quality is continuously decreasing requires the development of novel, effective and cost available adsorbents. Herein, a simple procedure for the preparation of a magnetic adsorbent from agricultural waste biomass and ferrofluid has been introduced. Specifically, ferrofluid mixed with wheat straw was directly pyrolyzed either by microwave irradiation (900 W, 30 min) or by conventional heating ($550^{\circ}C$, 90 min). Magnetic biochars were characterized by X-ray powder diffraction, $M{\ddot{o}}ssbauer$ spectroscopy, textural analysis and tested as adsorbents of As(V) oxyanion and cationic methylene blue, respectively. Results showed that microwave pyrolysis produced char with high adsorption capacity of As(V) ($Q_m=25.6mg\;g^{-1}$ at pH 4), whereas conventional pyrolysis was not so effective. In comparison to conventional pyrolysis, one-step microwave pyrolysis produced a material with expressive microporosity, having a nine times higher value of specific surface area as well as total pore volume. We assumed that sorption properties are also caused by several iron-bearing composites identified by $M{\ddot{o}}ssbauer$ spectroscopy ([super] paramagnetic $Fe_2O_3$, ${\alpha}-Fe$, non-stoichiometric $Fe_3C$, ${\gamma}-Fe_2O_3$, ${\gamma}-Fe$) transformed from nano-maghemite presented in the ferrofluid. Methylene blue was also more easily removed by magnetic biochar prepared by microwaves ($Q_m=144.9mg\;g^{-1}$ at pH 10.9) compared to using conventional techniques.

Physico-Chemical Characteristics of Municipal Solid Wastes in the East Coast of Gangwon (강원 동해안지역의 생활폐기물 발생특성)

  • Lee Hae-Seung;Choi Yog-Bum;Kim Byoung-Ug
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.1 s.55
    • /
    • pp.1-11
    • /
    • 2005
  • This research was performed to investigate the generation and physico-chemical characteristics of municipal solid wastes in the east coast of gangwon. The results were as follows: i) The generation rate of G city and Y gun were 0.187-0.384 $\cal{kg/cap/d}$ and 0.136-0.259 $\cal{kg/cap/d}$. Apparent density of G city and Y gun were 137.9-191.9 g/L and 157.3-238.3 g/L, respectively. ii) The wastes consisted of $76.1-97.5\%$ of combustibles and $2.5-23.9\%$ of incombustibles in G city. And the wastes consisted of $73.7-98.6\%$ of combustibles and $1.4-26.3\%$ of incombustibles in Y gun. Most of municipal solid wastes are composed of food, paper, and vinyl-plastics waste. Water content of commercial area, agricultural resident, detached resident, apartment area, school zone were 42.5-45.9, 37.6-43.4, 32.4-38.4, 29.3-32.3, $6.8-26.9\%$, respectively. iii) The low heating value of G city and Y gun were 1,125.5-2,540.7 $\cal{kcal/kg}$, 1,104.4-2,062.3 $\cal{kcal/kg}$, and school and apartment area were higher than commercial area.

Heat Transfer Characteristics of Tube Bundle Type Beat Exchanger for LFG and LNG Mixed Fuel (LFG와 LNG 혼합연료의 조성에 따른 다관형 열교환기에서의 열전달 특성)

  • Jeon Yong-Han;Kim Yong;Seo Tae-Beom
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.45-51
    • /
    • 2006
  • The purpose of this study is to investigate experimentally the heat transfer characteristics of combustion gas or a mixture fuel of LFG and LNG as compared LFG, LNG A Pilot combustion system is constructed. Tube bundle type heat exchangers with vertical and horizontal baffles are used, and the experiment is carried out for different operating conditions, the heating value, the concentration of methane (44.5%, 54.5%). The results show that the Nusselt number of LNG is higher than that of LFG at the same Reynolds number, and in case LFG, the Nusselt number of the mixture of LFG and LNG is larger than that of LFG alone. Therefore, heat transfer is improved by using LFG that is added to LNG pertinently, if and instability of LFG supply will be relaxed.

An Experimental Study on the Replication Ratio of Micro Patterns of 7 inch LGP using Injection/Compression and RHCM (사출/압축 및 RHCM 기술이 7인치 도광판 마이크로 패턴 전사성에 미치는 영향에 대한 실험적 연구)

  • Cho, S.W.;Kim, J.S.;Hwang, C.J.;Yoon, K.H.;Kang, J.J.
    • Transactions of Materials Processing
    • /
    • v.20 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • Recently, according to the rapid development of display, many display applications, such as, cellular phone, navigation, monitor and LCD TV have been changed from CRT type to LCD type. BLU(Back Light Unit) is one of main parts in LCD unit and generally, it consists of a light source, a reflective sheet, a LGP(Light Guide Plate), a diffuser sheet, and two prism sheets. The most important component of BLU is a light guide plate, which diffuses the input light to the TFT-LCD module uniformly. The LGP is usually made by injection molding process, and it has numerous optical micro patterns on the surface. In the present study the micro-patterned stamper which has cylindrical shape was fabricated by using the UV-LiGA process. And the replication characteristics have been compared among three different kinds of injection molding process; general injection molding, injection/compression molding and RHCM(Rapid Heating and Cooling Molding). Average replication ratios of CIM and ICM were 19.1% and 64.6%, respectively. On the other hand, the average replication ratio of RHCM process showed the higher value of 98.4% among these. It show that maintaining the mold surface above $T_g$ could increase the replication ratio of micro patterns substantially.

A Study on the Therapeutic Effectiveness of Hyperbaric Oxygenation on Acute CO poisoning (급성(急性) CO 중독시(中毒時) 고압산소요법(高壓酸素療法)의 치료효과(治療效果)에 관(關)한 연구(硏究))

  • Yun, Dork-Ro;Lee, Kan-Hyun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.5 no.1
    • /
    • pp.17-23
    • /
    • 1972
  • Carbon Monoxide poisoning is one of the most serious Public health problems in Korea. The incidence rate. officially reported has been known to be the highest in the world. This high incidence is mainly due to the wide prevalence of anthracite coal briquette as the domestic fuel for unique Korean heating system called 'ondol,' The coal briquette gas contains around 3-5% of Carbon Monoxide. A nation-wide effort to eliminate or reduce this serious hazards has produced little effect and the most hospitals are offering very ineffective measures such as oxygen inhalation through nasal catheter. Author has believed that this preventable accident should be approached by the secondary preventive measure because of our socio-economic status do not allow us optimistic results from primary preventive measure as far as the problem of CO poisoning is concerned. Author has treated 466 patients during 30 months period by Hyperbaric Oxygenation at Seoul National University Hospital. The results found are as follows. 1. Female has a higher incidence rate than male and the age group between 15-29 years showed highest incidence. 2. The recovery time depends on the time when the patients arrived at hospital. Earlier the arrival time, shorter the recovery time. 3. Some objective signs are representing typical physiological response to tissue hypoxia. 4. Therapeutic effectiveness of Hyperbaric Oxypenation is confirmed by such indices as recovery rate, Admission rate and average stay in hospital. Futher, these results are cocordant with other reports on the clinical value of Hyperbaric Oxygenation in the treatment of CO poisoning.

  • PDF

Influence of Reaction Parameters on Biocrude Production from Lipid-extracted Microalgae using Hydrothermal Liquefaction (열수액화를 이용한 미세조류 추출잔사로부터 바이오원유 제조에 대한 반응인자의 영향)

  • Ryu, Young-Jin;Shin, Hee-Yong;Yang, Ji-Hyun;Lee, Yunwoo;Jeong, Injae;Park, Hanwool;Lee, Choul-Gyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.9 no.2
    • /
    • pp.35-42
    • /
    • 2017
  • Hydrothermal liquefaction of lipid-extracted Tetraselmis sp. feedstock containing 80 wt.% water was conducted in a batch reactor at different temperatures (300, 325, and $350^{\circ}C$) and reaction times (5, 10, 20, 40, and 60 min). The biocrude yield, elemental composition and higher heating value obtained at various reaction conditions were used to predict the optimum conditions for maximizing energy recovery of biocrude with good quality. A maximum energy recovery of 67.6% was obtained at $325^{\circ}C$ and 40 min with a high energy density of 31.8 MJ/kg and lower contents of nitrogen and oxygen. Results showed that reaction conditions of $325^{\circ}C$, 40 min was most suitable for maximizing energy recovery while at the same time achieving improved quality of biocrude.

Ribose-induced Maillard Reaction as an Analytical Method for Detection of Adulteration and Differentiation of Chilled and Frozen-thawed Minced Veal

  • Akbarabadi, Masoumeh;Mohsenzadeh, Mohammad;Housaindokht, Mohammad-Reza
    • Food Science of Animal Resources
    • /
    • v.40 no.3
    • /
    • pp.350-361
    • /
    • 2020
  • Quality control of meat products is one of the main concerns of consumers, governmental control authorities, and retailers. The purpose of this study was to employ ribose-induced Maillard reaction in detection of meat adulteration and differentiation of fresh-chilled from frozen-thawed minced veal. The browning intensity was assessed through measuring the absorbance at 420 nm with a spectrophotometer as well as the direct analysis of the color and pH. The results showed that CIE b*, CIE a*, and A420* values in the extract of fresh-chilled veal were significantly (p<0.05) higher than frozen-thawed samples. The extract of frozen meat samples stored at -18℃ became significantly darker and more yellowish compared to -4℃. The results showed that the A420* value in the frozen-thawed veal stored at -4℃ and -18℃ was reduced by approximately 17.22±3.53% and 11.68±2.49%, respectively, compared with fresh-chilled veal. The findings also showed that the storage temperature of minced veal and the heating time in this reaction had a significant effect on all tested variables (p<0.0001). The proposed method can be considered as an easy, quick, and inexpensive test for differentiating between the fresh-chilled and frozen-thawed minced veal.