• 제목/요약/키워드: high-tension bolts

검색결과 60건 처리시간 0.019초

고장력볼트로 체결되는 철판 사이의 미끄럼계수 (Slip Coefficients between Steel Plates Fixed with High Tension Bolts)

  • 김충현
    • Tribology and Lubricants
    • /
    • 제24권6호
    • /
    • pp.338-342
    • /
    • 2008
  • Tensile test results using three kinds of steel structure specimens are measured and compared. Slip coefficient between shot blasted steel plates was greater than 0.6. For the case of the plates coated with Super zinc, it revealed that the coefficients were greater than 0.5. On the other hand, Super epoxy coating decreased its slip coefficient less than 0.25. Steel plates coated with Super zinc are proved to be practically applicable to the steel structures with anti-corrosion characteristics and clean surfaces.

Partially restrained beam-column weak-axis moment connections of low-rise steel structures

  • Lim, Woo-Young;Lee, Dongkeun;You, Young-Chan
    • Structural Engineering and Mechanics
    • /
    • 제76권5호
    • /
    • pp.663-674
    • /
    • 2020
  • In this study, partially restrained beam-column moment joints in the weak-axis direction were examined using three large-scale specimens subject to cyclic loading in order to assess the seismic resistance of the joints of low-rise steel structures and to propose joint details based on the test results. The influence of different number of bolts on the moment joints was thoroughly investigated. It was found that the flexural capacity of the joints in the direction of weak axis was highly dependent on the number of high-tension bolts. In addition, even though the flexural connections subjected to cyclic loading was perfectly designed in accordance with current design codes, severe failure mode such as block shear failure could occur at beam flange. Therefore, to prevent excessive deformation at bolt holes under cyclic loading conditions, the holes in beam flange need to have larger bearing capacity than the required tensile force. In particular, if the thickness of the connecting plate is larger than that of the beam flange, the bearing capacity of the flange should be checked for structural safety.

Plate Girder 볼트 이음부 강도에 관한 해석적 연구 (An Analytical Study for the Strength of the High Tension Bolted Joints in Plate Girder)

  • 함준수;황원섭;양성돈;정지승
    • 한국강구조학회 논문집
    • /
    • 제24권4호
    • /
    • pp.469-478
    • /
    • 2012
  • 본 논문은 강교량 이음부에서 고장력볼트의 유효활용방안을 모색하기 위하여 고장력볼트가 적용된 이음부에 관한 구조거동을 해석적으로 검토하였다. 또한, 비선형 유한요소프로그램인 ABAQUS의 Connector요소를 사용하여 간단하게 볼트의 거동을 표현하는 수치해석방법을 제안하고, 선행 연구의 실험을 토대로 수치해석을 실시하여 해석방법의 타당성을 검토하였다. 고장력볼트 이음부 강도에 영향을 미치는 주요 설계변수를 파악하기 위해 솔리드 요소를 사용한 인장 시험체를 선택하여 다양한 설계변수(모재 및 이음판의 강종, 이음판의 두께, 볼트 재료특성, 설계볼트축력)에 관한 영향을 비교 분석하였다. 또한, 플레이트 거더 볼트 이음부에서 고장력볼트 적용부위에 따른 강도특성을 분석하기 위하여 설계변수(상부 플랜지, 하부 플랜지, 상 하부플랜지, 웹)에 따른 구조물의 모멘트-변위 관계를 도출하여 각 설계변수가 극한거동에 미치는 영향을 비교 분석하였다.

Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Kim, Kang-Seok;Kim, Woo-Bum
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.477-488
    • /
    • 2009
  • A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.

실내환경과 건설현장 온도변수를 고려한 고력볼트 체결력 예측 (Estimation on Clamping Force of High Strength Bolts Considering Temperature Variable of Both Site conditions and Indoor Environments)

  • 나환선;이현주
    • 복합신소재구조학회 논문집
    • /
    • 제6권3호
    • /
    • pp.32-40
    • /
    • 2015
  • The torque shear high strength bolt is clamped normally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the required tension, as it considerably fluctuates due to torque coefficient dependent on lubricant affected temperature. In this study, the clamping tests of torque shear bolts were conducted independently at indoor conditions and at construction site conditions. During last six years, temperature of candidated site conditions was recorded from $-11^{\circ}C$ to $34^{\circ}C$. The indoor temperature condition was ranged from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. As for site conditions, the clamping force was reached in the range from 159 to 210 kN and the torque value was from 405 to $556 N{\cdot}m$. The range of torque coefficient at indoor conditions was analyzed from 0.126 to 0.158 while tensions were indicated from 179 to 192 kN. The torque coefficient at site conditions was ranged from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient, tension subjected temperature can be taken by statistic regressive analysis. The variable of torque coefficient under the indoor conditions is $0.13%/^{\circ}C$ while it reaches $2.73%/^{\circ}C$ at actual site conditions. When the indoor trends and site conditions is combined, the modified variable of torque coefficient can be expected as $0.2%/^{\circ}C$. and the modified variable of tension can be determined as $0.18%/^{\circ}C$.

내부보강형 CFT 기둥 기초 연결부의 거동특성에 대한 연구 (A Study on Behavioral Characteristics of Inner Reinforced CFT Column-to-Foundation Connections)

  • 김희주;함준수;정진일;황원섭
    • 복합신소재구조학회 논문집
    • /
    • 제5권4호
    • /
    • pp.36-43
    • /
    • 2014
  • In this study, circular sectional concrete-filled tube(CFT) column-to-foundation connections were numerically investigated in order to improve their structural details. A inner reinforced specimen with high-tension bolts and inner deformed bars was adopted from a previous experimental study to make the numerical model. The validity of the numerical method was verified through comparing the experimental results with the analysis's ones. In order to optimize design variables about the inner reinforced model, a number of numerical analyses were conducted for various variables. Finally, this study suggested the optimum variables about the reinforced circular sectional CFT column-to-foundation connections.

고장력 볼트 이음부의 내부 압축응력 분포 (Compressive Stress Distribution of High Tension Bolted Joints)

  • 김성훈;이승용;최준혁;장동일
    • 한국강구조학회 논문집
    • /
    • 제9권2호통권31호
    • /
    • pp.171-179
    • /
    • 1997
  • 고장력 볼트 이음부에서의 힘의 전달은 부재간의 압축력 및 볼트축력에 의하여 외력과 균형을 이룸으로서 형성되어지며, 부재간의 압축력, 도입된 축력의 변화 및 미끄러짐하중 등은 볼트 체결부 및 볼트의 유효강성에 지배된다. 이때 유효강성은 일반적으로 접합부의 유효단면적과 탄성계수의 곱으로 나타내어지지만 접합부재의 유효단면적이 어느 정도가 되는지는 판단하기가 쉽지가 않다. 이를 위해서 종래에는 이음부의 탄성변형에 관계하는 유효단면적을 등가중공원통형으로 가정하여 이에 대한 여러 가지 검토가 이루어졌다. 그러나 이러한 제안식들은 설계상의 목적과 복잡한 계산을 피하기 위하여 매우 단순화시킨 것으로 어느 식이 타당한 지는 단정하기가 어려우며 이에 대한 상세한 해석적인 검토 및 실험적인 검증이 요구된다. 따라서, 본 연구에서는 볼트 축력에 의한 접합부재의 유효단면적 산정과 이에 대한 검증을 위하여 고장력 볼트 이음 시험편에 대해 피로시험을 실시하고 반복하중 재하 후의 마찰면의 형상을 관찰하여 유효마찰 영역을 측정하였으며, 유한 요소법에 의해 수치 해석을 실시하여 내부 압축응력의 분포형상을 밝히고 접촉면상에 발생하는 응력 분포영역을 근사화하므로서 마찰면의 형상과 내부 압축응력의 분포영역과의 관계 그리고 유효단면적의 산정 방법을 고찰하였다.

  • PDF

이음면 이격이 확장형 단부판 이음부 성능에 미치는 영향에 대한 실험적 연구 (Experimental Study of the End-plate Gap Effect on the Performance of Extended End-plate Type Splice)

  • 김철환;이명재;김희동;김사빈
    • 한국강구조학회 논문집
    • /
    • 제28권6호
    • /
    • pp.427-438
    • /
    • 2016
  • 두본 연구는 실험적인 방법을 통하여 단부판 이음부의 이음면에서 초기 오차로 발생하는 이격이 이음부의 내력 및 거동에 미치는 영향을 평가한 연구이다. 이를 위하여 총 5가지의 단순보형 실험체를 확장형 단부판 이음부를 이용 계획하였고 주요 변수로는 이음면 초기 이격(gap) 여부, 고력볼트 채결 전 끼움판(finger shim plate) 설치 유무, 고력볼트 체결 후 이음면 이격, 고력볼트 채결 후 끼움판 삽입 여부를 적용하였다. 정적가력실험 결과 이음판의 이격은 이음부의 최대휨강도에 미치는 영향은 제한적이나 수직변형과 초기 및 탄성강성에는 영향을 미치는 것으로 나타났으며, 이격을 제어하기 위해 고력볼트 장력을 이용할 경우 고력볼트의 취성파괴 우려도 있는 것으로 나타나서 이들에 대한 충분한 고려가 필요할 것으로 판단된다.

음탄성법을 이용한 고장력 볼트의 축응력 평가 (Estimation of the Axial Stress in High-Tension Bolt by Acoustoelastic Method)

  • 전해화;이태훈;장경영;김노유
    • 비파괴검사학회지
    • /
    • 제26권5호
    • /
    • pp.285-290
    • /
    • 2006
  • 고장력볼트의 체결상태를 평가하는 것은 체결볼트의 안전유지관리 측면에서 매우 중요하다. 본 논문에서는 초음파의 음속이 응력에 의존하는 이른바 음탄성효과에 기초하여 초음파의 전파시간(TOF)를 측정함으로써 볼트에 작용하는 축응력을 평가하는 방법을 제안한다. 그런데 일반적으로 볼트체결시 볼트에 작용하는 응력범위내에서의 음속 변화량은 매우 작으며, 따라서 TOF 측정에 있어서 높은 정밀도가 요구된다. 이를 위해 본 논문에서는 톤버스트파형의 초음파를 이용한 위상검출법을 적용하였다. 제안된 원리는 실험을 통해 검증되었으며, 볼트 축응력 측정의 유효성을 검증하기 위해 스트레인게이지를 이용한 축응력 측정결과와 비교하였다. 두 결과는 양호한 일치를 보였으며, 이로써 제안한 방법이 체결된 고장력볼트의 체결상태 평가에 유용하다는 결론을 얻을 수 있었다.

고력볼트 시공환경에 따른 토크계수와 체결축력에 관한 실험적 연구 (Experimental Study on the Torque Coefficient and Clamping Force of High Strength Bolts Subjected to Environmental Parameters)

  • 이현주;나환선;김강석;김진호;김진만
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.43-53
    • /
    • 2008
  • 현재 국내에서 현장 체결공법으로 채용하고 있는 토크관리법은 토크계수를 근거로 해서 간접적으로 도입축력을 제어하는 방법이기 때문에 현장에서의 토크계수 관리가 상당히 중요하다. 따라서 본 연구에서는 현장 시공시 볼트보관방법 및 현장관리에서 일반적으로 발생할 수 있는 주요 환경 요인 중 수분 침투, 녹 발생, 외기노출, 와셔의 오용 등 다양한 실험변수로 계획하여 토크계수의 변화에 따른 도입축력의 차이를 확인하기 위하여 실험을 수행했다. 실험에 사용된 볼트는 육각 고력볼트, TS 고력볼트, 아연피막처리 육각 고력볼트, ASTM A490 고력볼트로서 4종류로 구분하여 수행되었고, 각 볼트별로 시공환경에 따른 체결특성을 비교 분석하였다.