Browse > Article
http://dx.doi.org/10.11004/kosacs.2015.6.3.032

Estimation on Clamping Force of High Strength Bolts Considering Temperature Variable of Both Site conditions and Indoor Environments  

Nah, Hwan-Seon (Korea Electric Power Corporation Research Institute)
Lee, Hyeon-Ju (Korea Electric Power Corporation Research Institute)
Publication Information
Journal of the Korean Society for Advanced Composite Structures / v.6, no.3, 2015 , pp. 32-40 More about this Journal
Abstract
The torque shear high strength bolt is clamped normally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the required tension, as it considerably fluctuates due to torque coefficient dependent on lubricant affected temperature. In this study, the clamping tests of torque shear bolts were conducted independently at indoor conditions and at construction site conditions. During last six years, temperature of candidated site conditions was recorded from $-11^{\circ}C$ to $34^{\circ}C$. The indoor temperature condition was ranged from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. As for site conditions, the clamping force was reached in the range from 159 to 210 kN and the torque value was from 405 to $556 N{\cdot}m$. The range of torque coefficient at indoor conditions was analyzed from 0.126 to 0.158 while tensions were indicated from 179 to 192 kN. The torque coefficient at site conditions was ranged from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient, tension subjected temperature can be taken by statistic regressive analysis. The variable of torque coefficient under the indoor conditions is $0.13%/^{\circ}C$ while it reaches $2.73%/^{\circ}C$ at actual site conditions. When the indoor trends and site conditions is combined, the modified variable of torque coefficient can be expected as $0.2%/^{\circ}C$. and the modified variable of tension can be determined as $0.18%/^{\circ}C$.
Keywords
high strength bolt; torque; tension; torque-coefficient; estimation;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Architectural Institute of Japan (2003), Guidebook on Design and Fabrication of High Strength Bolted Connections, AIJ.
2 ASTM F 2280-06 (2006), Twist Off Type Tension Control Structural Bolt/Nut/Washer Assemblies, Steel, Heat Treated, 150ksi Minimum Tensile Strength, ASTM International, Philadelphia, PA, USA.
3 ASTM F959M, Standard Specification for Compressible-Washer-Type Direct Tension Indicators for use with Structural Fasteners, ASTM International, Philadelphia, PA, USA.
4 Bickford, John H.(1990), An Introduction to the Design and Behavior of Bolted Joints, Marcel Dekker Inc., Madison Avenue, New York, NJ.
5 Khairedin Abdalla, Dimitrios N. Kaziolas, Charalambos C.Baniotopoulos (2011), "Tightening and Loosening Torque of M253 Bolts : Experimental and Analytical Investigation", International Journal of Engineering and Information Sciences, 6(2), pp. 69-83.
6 Kulak, Geoffrey L.,Fisher, John W., Struik, John H.A.(2001), Guide to Design Criteria for Bolted and Riveted Joints, 2nd Ed., AISC Inc.
7 Nah, H. S., Lee, H. J., and Choi, S. M. (2014), "Evaluating long-term relaxation of high strength bolts considering coating on slip faying surface"', Steel and Composite Structures, Vol. 16, No. 6, pp. 703-718.   DOI   ScienceOn
8 Nah, H. S., Lee, H. J., Kim, K. S., Kim, J. H. and Kim, W. B. (2009a), "Method for Estimating the Clamping Force of High Strength Bolts Subjected to Temperature Variation", International Journal of Steel Structures, Vol. 9, No. 2, pp. 123-130.   DOI
9 Nah, H. S., Lee, H. J., Kim, K. S., Kim, J. H. and Kim, W. B. (2009b), "Evaluation of Slip Coefficient of Slip Critical Joints with High Strength Bolts", Structural Engineers & Mechanics, Vol. 32, No. 4, pp. 477-488.   DOI   ScienceOn
10 Nah, H. S., Lee, H. J., Choi, S. M. and Kim, W. B.(2015), "Analysis on Variation of Torque Co-efficient by Ambient Temperature of High Strength Bolt", Proc. 5th KOSACS Conference, Jeju, Korea, pp.95-96 (in Korean).
11 RCSC Committee(2004), Specification for Structural Joints Using ASTM A325 or A490 Bolts, AISC Inc., Chicago, Illinois, USA.
12 Tambori, Akbar R.(1999), Handbook of structural steel connection design and detail Design, MaGraw-Hill, USA.
13 Vand, E. Hemmati, Oskouei R.H., Chakherlou T.N., (2008) "Experimental Method for Measuring Clamping Force in Bolted Connections and Effect of Bolt Threads Lubrication on its Value", World Academy of Science, Engineering and Technology 22, pp. 457-460.