• Title/Summary/Keyword: high-dose therapy

Search Result 635, Processing Time 0.145 seconds

The evaluation of lens absorbed dose according to the Optimold for whole brain radiation therapy (전뇌 방사선치료 시 Optimold에 따른 수정체의 흡수선량 평가)

  • Yang, Yong Mo;Park, Byoung Suk;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 2014
  • Purpose : In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. Materials and Methods : In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made ??up to 5mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. Results : When there was the Optimold mask in the eyeball part, it was measured at $10.2cGy{\pm}1.5$ in the simulation therapy, and at $24.8cGy{\pm}2.7$ in the treatment, and when the Optimold mask was removed in the eye part, it was measured at $12.9cGy{\pm}2.2$ in the simulation therapy, and at $17.6cGy{\pm}1.5$ in the treatment. Conclusion : In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3 cGy in the simulation therapy and was reduced approximately 7 cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause cataracts and side effects was considered to be reduced due to decrease of the absorbed dose to the eye lens which had the high sensitivity on the radiation.

A Case of Amiodarone-Induced Pulmonary Toxicity After a Long Course of a Low Dose Therapy (장기간 사용한 저용량 Amiodarone에 의한 폐독성 1예)

  • Ryu, Jung-Il;Lee, Wan-Suk;Hyun, Dae-Sung;Lee, Sang-Chae;Shin, Tae-Rim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.656-661
    • /
    • 2002
  • Amidarone is one of the most commonly prescribed anti-arrythmic agents for almost all arrythmias, whether atrial or ventricular in origin. There are several side effects associated with amiodarone therapy. These include corneal deposits, abnormal liver function tests, hyper and hypothyroidism, bluish discolorations of the skin, bone marrow suppression, coagulopathies, peripheral neuropathies, and pulmonary toxicity. Amiodarone-induced pulmonary toxicity(APT), which was first described in 1980, is potentially serious side effects that are believed to develop in 5% of patients. Doctors often assume that APT occurs only when high amiodarone doses are used for a long time, but in practice a low maintenance dose of amiodarone may also be toxic. In this report, a case of amiodarone-induced pulmonary toxicity after a long course of a low dose therapy for refractory supraventricular arrythmia is described.

A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients (갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구)

  • Kim, Seongcheol;Gwon, DaYeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.597-603
    • /
    • 2017
  • High-dose $^{131}I$ therapy has been generally carried out to remove remaining thyroid tissue or to cure metastasize lesion of patients who received full thyroidectomy due to differentiated thyroid cancers. In case high-dose $^{131}I$ therapy is carried out for a patient, the patient should be hospitalized being isolated for a certain period in order to restrict the amount of exposure to radiation of people at large from the patient within the limit of a level of radiation. Effective half-life is an important value to calculate how family members are exposed to radiation from a patient or to decide the period of isolation of the patient from the family members. Therefore, in this study we calculated the effective decay constant, effective half-life and period of isolation of high-dose $^{131}I$ therapy patient using NM670 SPECT/CT. As a result of carrying out this study, the effective half-life of high-dose $^{131}I$ therapy patients was derived and the time to reach the discharge level of 1.2 GBq was confirmed. When they were compared with each other in each of curative doses, the effective half-life did not have significant difference, but the time when the level of radiation remaining in the interior of the body to reach the criteria of isolation and discharge showed significant difference and it could be confirmed that the higher the curative dose the longer the period of isolation becomes. When the effective half-lives in each type of preparation were compared with each other, they did not show significant difference. However, When the times to reach the level of radiation that is the criteria of isolation and discharge in each type of preparations, they showed significant difference. The cause of the shortening of the isolation period for rhTSH patients group is decided to be low curative dose. Accordingly, if the current national health insurance (the insurance is applied to using of rhTSH in 3.7 GBq or lower) is maintained, while discerning them in each of types of preparation, we would be able to discharge patients at the time earlier than the current period of isolation (2 nights and 3 days).

Review of the Existing Relative Biological Effectiveness Models for Carbon Ion Beam Therapy

  • Kim, Yejin;Kim, Jinsung;Cho, Seungryong
    • Progress in Medical Physics
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Hadron therapy, such as carbon and helium ions, is increasingly coming to the fore for the treatment of cancers. Such hadron therapy has several advantages over conventional radiotherapy using photons and electrons physically and clinically. These advantages are due to the different physical and biological characteristics of heavy ions including high linear energy transfer and Bragg peak, which lead to the reduced exit dose, lower normal tissue complication probability and the increased relative biological effectiveness (RBE). Despite the promising prospects on the carbon ion radiation therapy, it is in dispute with which bio-mathematical models to calculate the carbon ion RBE. The two most widely used models are local effect model and microdosimetric kinetic model, which are actively utilized in Europe and Japan respectively. Such selection on the RBE model is a crucial issue in that the dose prescription for planning differs according to the models. In this study, we aim to (i) introduce the concept of RBE, (ii) clarify the determinants of RBE, and (iii) compare the existing RBE models for carbon ion therapy.

Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber (평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Park, So-Hyun;Jeong, Ho-Jin;Hwang, Ui-Jung;Ahn, Sung-Hwan;Lim, Young-Kyung;Kim, Dong-Wook;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Suh, Tae-Suk;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, $Z_{ret}=0.6R_{50}-0.1$ in water phantom. The $D_W$ of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the $D_W$ of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.

  • PDF

Surfer's Myelopathy : Case Series and Literature Review

  • Choi, June Ho;Ha, Jung-Ki;Kim, Chung Hwan;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.767-773
    • /
    • 2018
  • Three male patients diagnosed with surfer's myelopathy (19-30 years) were admitted to our hospital. All three patients were novice surfers showing a typical clinical course of rapid progression of paraplegia following the onset of back pain. Typical history and magnetic resonance imaging features indicated the diagnosis of surfer's myelopathy. Two patients received high-dose steroid therapy and the other was treated with induced hypertension. One patient treated with induced hypertension showed almost full recovery; however, two patients who received high-dose steroid therapy remained completely paraplegic and required catheterization for bladder and bowel dysfunction despite months of rehabilitation. Our case series demonstrates the potentially devastating neurological outcome of surfer's myelopathy; however, early recovery in the initial 24-72 hours of presentation can occur in some patients, which is in accordance with previous reports. Ischemic insult to the spinal cord is thought to play a crucial role in the pathophysiology of surfer's myelopathy. Treatment recommendations include hydration, induced hypertension, early spinal angiography with intra-arterial intervention, intravenous tissue plasminogen activator, and high-dose steroid therapy; however, there is no standardized treatment option available. Early recovery appears to be important for long-term neurological outcome. Induced hypertension for initial treatment can be helpful for improving spinal cord perfusion; therefore, it is important for early and long-term neurological recovery. Education and awareness are essential for preventing surfer's myelopathy and avoiding further deterioration of neurological function.

The Effect of Photoneutron Dose in High Energy Radiotherapy (10 MV 이상 고에너지 치료 시 발생되는 광중성자의 영향)

  • Park, Byoung Suk;Ahn, Jong Ho;Kwon, Dong Yeol;Seo, Jeong Min;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2013
  • Purpose: High-energy radiotherapy with 10 MV or higher develops photoneutron through photonuclear reaction. Photoneutron has higher radiation weighting factor than X-ray, thus low dose can greatly affect the human body. An accurate dosimetric calculation and consultation are needed. This study compared and analyzed the dose change of photoneutron in terms of space according to the size of photon beam energy and treatment methods. Materials and Methods: To measure the dose change of photoneutron by the size of photon beam energy, patients with the same therapy area were recruited and conventional plans with 10 MV and 15 MV were each made. To measure the difference between the two treatment methods, 10 MV conventional plan and 10 MV IMRT plan was made. A detector was placed at the point which was 100 cm away from the photon beam isocenter, which was placed in the center of $^3He$ proportional counter, and the photoneutron dose was measured. $^3He$ proportional counter was placed 50 cm longitudinally superior to and inferior to the couch with the central point as the standard to measure the dose change by position changes. A commercial program was used for dose change analysis. Results: The average integral dose by energy size was $220.27{\mu}Sv$ and $526.61{\mu}Sv$ in 10 MV and 15 MV conventional RT, respectively. The average dose increased 2.39 times in 15 MV conventional RT. The average photoneutron integral dose in conventional RT and IMRT with the same energy was $220.27{\mu}Sv$ and $308.27{\mu}Sv$ each; the dose in IMRT increased 1.40 times. The average photoneutron integral dose by measurement location resulted significantly higher in point 2 than 3 in conventional RT, 7.1% higher in 10 MV, and 3.0% higher in 15 MV. Conclusion: When high energy radiotherapy, it should consider energy selection, treatment method and patient position to reduce unnecessary dose by photoneutron. Also, the dose data of photoneutron needs to be systematized to find methods to apply computerization programs. This is considered to decrease secondary cancer probabilities and side effects due to radiation therapy and to minimize unnecessary dose for the patients.

  • PDF

A Successfully Treated Case of Recurrent Focal Segmental Glomerulosclerosis (FSGS) with Plasmapheresis and High dose Methylprednisolone Pulse Therapy

  • Her, Sun Mi;Lee, Keum Hwa;Shin, Jae Il
    • Childhood Kidney Diseases
    • /
    • v.21 no.2
    • /
    • pp.165-168
    • /
    • 2017
  • Focal segmental glomerulosclerosis (FSGS) in children, which is a kind of nephrotic syndrome showing steroid resistance, usually progresses to a substantial number of end stage renal disease (ESRD). Although the pathogenesis of primary FSGS is unclear, several recent studies have reported that FSGS is associated with circulating immune factors such as soluble urokinase-type plasminogen activator receptor (suPAR) or anti-CD40 autoantibody. We report a successfully treated case of a 19-year-old female patient who experienced a recurrence of primary FSGS. After the diagnosis of FSGS, the patient progressed to ESRD and received a kidney transplantation (KT). Three days later, recurrence was suspected through proteinuria and hypoalbuminemia. She has been performed plasmapheresis and high dose methylprednisolone pulse therapy and shown remission status without increasing proteinuria for four years after KT. In conclusion, strong immunosuppressive therapy may be helpful for a good prognosis of recurrent FSGS, suppressing several immunologic circulating factors related disease pathogenesis.

A Case of Intractable Hiccups Associated with High Dose Intravenous Methylprednisolone in a Patient with Third Nerve Palsy (동안신경마비 환자에서 고용량 메칠프레드니솔론 정주 후 발생한 난치성 딸꾹질 1예)

  • Na, Sang-Jun;Yum, Kyu Sun;Lee, Kee Ook
    • Annals of Clinical Neurophysiology
    • /
    • v.10 no.1
    • /
    • pp.79-82
    • /
    • 2008
  • The etiology of intractable hiccups is most commonly idiopathic. However, they are occasionally associated with some underlying disorders including gastro-esophageal reflux disease. There are a few previous reports describing the association of intractable hiccups with high dose corticosteroid. We experienced an unusual case of intractable hiccups following a high dose intravenous methylprednisolone therapy in a patient with right third nerve palsy. Since methylprednisolone is commonly used in various neurological problems, physicians should be aware of its possible side effect including intractable hiccups.

  • PDF

Accuracy of Dose Estimation in High Dose Rate Intracavitary Radiotherapy of Carcinoma of the Uterine Cervix (자궁경부암 고선량율 강내치료의 치료선량 정확도에 관한 연구)

  • Huh, Seung-Jae;Ha, Sung-Whan;Chai, Kyu-Young
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.137-140
    • /
    • 1987
  • In brachytherapy of uterine conical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. The post-treatment calculated point A dose was not much different from the pretreatment planned dose (500 cGy). The $average{\pm}standard$ deviation was $500\pm18cGy$ and 84 percent of 82 intracavitary radiotherapy was within the range of $500\pm25cGy$.

  • PDF