• Title/Summary/Keyword: high temperature superconducting coil

Search Result 129, Processing Time 0.027 seconds

Performance Test of 1MW class High-temperature Superconducting Motor for Industry Application (1MW 급 산업용 고온초전도 모터 특성 평가)

  • Baik, S.K.;Kwon, Y.K.;Kim, J.M.;Lee, J.D.;Lee, E.Y.;Kim, Y.C.;Moon, T.S.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.142-143
    • /
    • 2007
  • A 1MW class HTS(High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of Neon thermosiphon mechanism and the stator coil is cooled by water through hollow copper conductor. This paper describes performance test results of our motor, which was conducted at steady state in generator mode and motor mode.

  • PDF

Transient loss analysis of non-insulation high temperature superconducting coil using the field-based data profiling method

  • Hoon Jung;Yoon Seok Chae;June Hee Han;Ji Hyung Kim;Seung Hoon Lee;Ho Chan Kim;Young Soo Yoon;Ho Min Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.38-42
    • /
    • 2023
  • The evaluation of no-insulation (NI) high-temperature superconducting (HTS) typically uses the lumped equivalent circuit (LEC) model. Constant parameters in the NI HTS LEC model accurately predict voltage and central magnetic field at currents below the critical current. However, it is difficult to find constant circuit parameters that simultaneously satisfy the measured voltage and magnetic field under overcurrent conditions. Recent research highlights changes in contact resistance during transient conditions, which may impact power loss estimation in NI HTS coils. Therefore, we confirm the influence of contact resistance changes on loss calculation in the transient state for NI HTS coil. To achieve this, we introduce a measurement data analysis method based on the LEC model and compare it with the LEC model using constant circuit parameters.

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.

A Study of Magnetic Field Characteristic of Field coil in HTS motor (HTS 전동기용 계자코일의 자장 특성 연구)

  • 이정종;조영식;홍정표;손명환;김석환;권영길
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.47-51
    • /
    • 2002
  • In this paper, flux distribution and operating current is calculated according to the field coil change in HTS(High Temperature Superconducting) motor. In order to calculate magnetic field characteristic of the field coil. it is computed by changing the outer radius and the inner width of field coil Bio-Savart equation is used as the analysis method for the characteristic analysis of magnet. 2D and 3D FEA(Finite Element Analysis) is used for the magnetic field distribution in HTS motor The operating current is calculated by $B{\bot}$ linked With the field coil and $I_c-B curve of superconductor.

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Effect of Epoxy Cracking on Initial Quench Behavior about High Field Superconducting Magnet

  • Lee, B.S.;Kim, D.L.;Choi, Y.S.;Yang, H.S.;Yoo, J.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.4
    • /
    • pp.26-29
    • /
    • 2006
  • The study to be presented related on initial behavior of quench concerned with many considerations, such as epoxy impregnated coil, critical current density related on strain and temperature, winding effect and behavior of internal superconducting wire. Especially, the deformation behavior of coils under magnetic field and thermal contractions at cryogenic temperatures to be dealt with the analytical method related on Fracture Mechanics. From the results, we know that the strain by self weight contribute to epoxy cracking at the edge of deformed coils and the deformation behavior relate on epoxy cracking must be dealt with biaxial loading problem. Then, the epoxy crack on $r\theta-plane$ under biaxial loading have been propagated with inclined crack angle and joined superconducting wire. Also, we can explain transfer of epoxy crack propagation energy from epoxy resin to superconducting wire.

Characteristic of Magnetic Field Distribution of 100hp Class High Temperature Superconducting motor (100hp급 고온초전도 모터의 자장분포특성)

  • 이정종;조영식;주진홍;홍정표;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.312-314
    • /
    • 2002
  • Magnetic circuit design of HTS (High Temperature Superconducting) motor is important to achieve the power at a given load condition, and it is essential to the thermal design for HTS motor rotors. To determine the result of thermal design, the magnetic field distribution has to be known exactly. On the basis of the 2 dimensional magnetic field analysis, the magnetic field distributions due to several cases are calculated by using Biot-Savart equation and magnetic image method. And the I$_{c}$ of HTS field coil was calculated by using I$_{c}$-B(equation omitted) curve and 3D FEA(Finite Element Analysis).is).

  • PDF

A Study of a Conduction Cooling System of a HTS SMES System (고온초전도체 SMES 장치의 전도냉각시스템 연구)

  • Koh, Deuk-Yong;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.328-332
    • /
    • 2007
  • A superconducting magnetic energy storage (SMES) system has shorter response time and longer life time, and is more economical, and environment-friendly than other uninterruptible power supply (UPS). A conduction cooling system is well answer for the high temperature superconductor (HTS) SMES system. Because the conduction cooling system is simple, light and small structure. The purpose of this paper is to design and verify the effective conduction cooling system for the HTS SMES system. The analysis of heat loads in cryostat is performed. Thermal shield heat loads, temperatures of HTS coil surface and conduction Cu plate are estimated and measured.

Estimation of Bubble Behavior and PD Initiation Voltage in the Simulated Electrode System of High Temperature Superconducting Coils (고온초전도코일 모의전극계에서 기포거동 및 부분방전개시전압의 추정)

  • Seok, Bok-Yeol;Choi, Myung-Joon;Kim, Yong-Han;Kim, Jin-Soo;Kim, Jong-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1771-1773
    • /
    • 2001
  • This paper deals with the numerical estimation of the bubble behavior and the partial discharge(PD) initiation voltage basis of electric field calculation with the coaxial coil layer-to-cylindrical electrode system for the simulation of high temperature superconducting coils. The theoretical results of bubble behavior and the PD initiation voltages showed fairly good agreements with the experimental results.

  • PDF

Conceptual design of current lead for large scale high temperature superconducting rotating machine

  • Le, T.D.;Kim, J.H.;Park, S.I.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.54-58
    • /
    • 2014
  • High-temperature superconducting (HTS) rotating machines always require an electric current of from several hundreds to several thousand amperes to be led from outside into cold region of the field coil. Heat losses through the current leads then assume tremendous importance. Consequently, it is necessary to acquire optimal design for the leads which would achieve minimum heat loss during operation of machines for a given electrical current. In this paper, conduction cooled current lead type of 10 MW-Class HTS rotating machine will be chosen, a conceptual design will be discussed and performed relied on the least heat lost estimation between conventional metal lead and partially HTS lead. In addition, steady-state thermal characteristic of each one also is considered and illustrated.