This paper deals with the numerical estimation of the bubble behavior and the partial discharge(PD) initiation voltage basis of electric field calculation with the coaxial coil layer-to-cylindrical electrode system for the simulation of high temperature superconducting coils. The theoretical results of bubble behavior and the PD initiation voltages showed fairly good agreements with the experimental results.