• 제목/요약/키워드: high performance liquid chromatography-mass spectrometry (HPLC-MS)

검색결과 140건 처리시간 0.025초

Identification of IY81149 and Its Metabolites in the Rat Plasma Using the On-Line HPLC/ESI Mass Spectrometry

  • Myung, Seung-Woon;Min, Hye-Ki;Jin, Chang-Bae;Kim, Myung-Soo;Lee, Seung-Mok;Chung, Gi-Ju;Park, Seong-Jun;Kim, Dong-Yeon;Cho, Hyun-Woo
    • Archives of Pharmacal Research
    • /
    • 제22권2호
    • /
    • pp.189-193
    • /
    • 1999
  • Reversed-phase high-performance liquid chromatography/mass spectrometry (HPLC/MS) with an eletcrospray ionization (ESI) interface was applied to the identification of metabolites of IY81149 in the rat plasma. Fragments obtained using collision-induced dissociation (CID) in both positive and negative modes were utilized to elucidate the structure of metabolites. The eluent from the conventional HPLC column was split and directly introduced into an ESI-mass spectrometer for the identification of the structures. the CID technique allowed the sensitive identification of sulfonyl-IY81149 and hydroxy-IY81149 from the rat plasma.

  • PDF

Analysis of Carotenoids in 25 Indigenous Korean Coral Extracts

  • Kim, Sang Min;Kang, Suk-Woo;Lee, Eun A;Seo, Eun-Kyoung;Song, Jun-Im;Pan, Cheol-Ho
    • Journal of Applied Biological Chemistry
    • /
    • 제56권1호
    • /
    • pp.43-48
    • /
    • 2013
  • In this study, methanol extracts from 25 indigenous Korean corals were prepared and their carotenoid constituents were analyzed by high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS). Among them, extracts from nine species showed detectable peaks in the HPLC chromatogram at 450 nm and the ultraviolet/visible spectra exhibiting carotenoid-specific characteristics were chosen. The mass data of carotenoid peaks revealed that only peridinin could be identified based on literature comparison and suggested the potential presence of novel carotenoid structures. This is the first reported investigation of indigenous Korean coral carotenoids and further work is needed to explore the carotenoids and their potential roles in the ecosystem of indigenous Korean corals.

A Simple and Sensitive High Performance Liquid Chromatography-Electrospray Ionization/Mass Spectrometry Method for the Quantification of Ethyl Pyruvate in Rat Plasma

  • Kim, Hyun-Ji;Kim, Seung-Woo;Lee, Ja-Kyeong;Yoon, Sung-Hwa
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권4호
    • /
    • pp.1221-1227
    • /
    • 2011
  • Ethyl pyruvate (EP) is known as a scavenger of reactive oxygen species (ROS) in the body through its role in the donation of diketone groups to metals to form an EP-metal complex. In order to develop a method for the quantification of EP in biological media, a sensitive and specific, high-performance liquid chromatographyelectrospray ionization-mass spectrometry (HPLC-ESI/MS) method is used to determine the EP-alkali metal ion binding species. The analyte was separated on a ZORBOX SB-C8 ($3.5{\mu}m$, $30mm{\times}2.1mm$ I.D.) column and analyzed in selected ion monitoring (SIM) mode with a positive ESI interface using the m/z 255 $[2M + Na]^+$ ion. The method was validated over the concentration range of $0.5-60.0\;{\mu}g$/mL under 1/9 (v/v) of acetonitrile/methanol solvent system with flow rate 0.05 mL/min. The limit of quantification (LOQ) was $0.5{\mu}g$/mL.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2006년도 추계학술대회
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

셀레늄이 강화된 이스트에서 셀레늄 단백질의 분리 및 확인 (Separation and identification of selenoproteins in selenium-enriched yeast)

  • 김경미;박용남
    • 분석과학
    • /
    • 제26권6호
    • /
    • pp.357-363
    • /
    • 2013
  • Selenium-containing proteins were separated from selenium-enriched yeast (SEY) using Trizol$^{(R)}$ reagent followed by anion exchange (AE) chromatography. This method is simpler and less time consuming than electrophoresis. Five selenium containing proteins were identified by on-line AE HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry). Each protein was enzymatically hydrolyzed to seleno-amino acids and separated with RP (reverse phase) HPLC for the identification of selenoproteins.

Discrimination of biological and artificial nicotine in e-liquid

  • Hyoung-Joon Park;Heesung Moon;Min Kyoung Lee;Min Soo Kim;Seok Heo;Chang-Yong Yoon;Sunyoung Baek
    • 분석과학
    • /
    • 제36권1호
    • /
    • pp.22-31
    • /
    • 2023
  • As the use of e-liquid cigarettes is rapidly increasing worldwide, it multiplies the potential risk undisclosed to the health of non- and smokers. To reduce the hazard, each country has its own set of regulations for controlling e-liquids. In Korea, the narrow definition of tobacco makes it difficult and have been steadily occurring tax evasion exploiting the difference in natural and artificial nicotine. Therefore, it is very important to distinguish source of nicotine for their regulation. To find biochemical discriminant markers, this study established analysis methods based on high-performance liquid chromatography coupled with diode array detector (HPLC-DAD) and high-performance liquid chromatography coupled with triple Quadrupole mass spectrometry (HPLC-MS/MS) for nicotine enantiomers and tobacco alkaloids targeted using the difference in pathways of nicotine biosynthesis and chemical synthesis. The method was validated by experimenting linearity (R2 > 0.999), recovery (80.99-108.41 %), accuracy (94.11-109.73 %) and precision (0.04-8.27 %). Then, the results for discrimination of the nicotine obtained from analysis of 65 commercial e-liquid products available in Korean market was evaluated. The method successfully applied to the e-liquids and one sample labelled 'synthetic nicotine' for tax exemption was found to contain a natural nicotine product. This method can be used to determine whether an e-liquid product uses natural or artificial nicotine and monitor non-taxable e-liquid products. The method is more scientific than the existing one, which relies only on field evidence.

Measurement of the Rate of Protein Synthesis in Chickens by HPLC/MS

  • Seo, S.S.;Coon, C.
    • 한국가금학회지
    • /
    • 제31권3호
    • /
    • pp.137-143
    • /
    • 2004
  • The fractional synthesis rates(FSR) were measured with 2l-wk and 3l-wk-old broiler breeder pullets and hens to investigate the effect of sexual maturity on FSR. The FSR were obtained from chicken tissues and blood samples using High-Performance Liquid Chromatography/Mass Spectrometry(HPLC/MS). A L-l-13C, 15N -leucine saline solution was infused by bolus injection as a tracer into broiler breeder pullets in the experiment. A rapid HPLC/MS method was developed to measure the isotopic enrichments of leucine in plasma, tissue samples, and eggs. The enrichments of stable isotope leucine incorporated into protein and the enrichments of the stable isotope free leucine were measured in liver, breast muscle and blood samples. Two sets of experiments were conducted. In experiment one, 2l-wk-old, sexually immature broiler breeder pullets were divided into groups of three and blood samples were collected at 20 or 30 min intervals until 1.5 h from initial injection. The pullets were sacrificed in groups of three at varying time intervals for 7 h after injection. The liver, breast muscle and blood samples were removed for analysis. The FSR were estimated to be 8.7l%/day for liver, 4.06%/day for breast muscle, and 5.08%/day for blood samples in 30 minutes after injection from the enrichment ratios. In experiment two, sexually matured 3l-wk-old broiler breeder hens were assorted into groups of three and blood samples were obtained at 20 or 30 min intervals for 2 h. The FSR for blood samples were determined. The broiler breeder hens were sacrificed in groups of three at various time intervals until 7 h after injection and liver, breast muscle and blood samples were removed for analysis. The FSR were calculated to be 5.96%/day for liver. Eggs were collected from five chickens daily for 10 days after large bolus injection. The average of total enrichments of stable isotope in egg albumin was increased by 0.064% at 4 days after injection and was back to normal in 7 days.

Use of Lycopene, an Antioxidant Carotinoid, in Laying Hens for Egg Yolk Pigmentation

  • Kang, D.-K.;Kim, S.-I.;Cho, C.-H.;Yim, Y.-H.;Kim, H.-S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권12호
    • /
    • pp.1799-1803
    • /
    • 2003
  • The possibility of lycopene affecting egg yolk pigmentation was studied with lycopene diets containing 0, 4, 8, and $12{\mu}g/g$ meal, respectively. The addition of lycopene above $4{\mu}g/g$ meal significantly improved yolk color after four days of supplementation. The transfer of lycopene into egg yolk was confirmed by thin layer chromatography, and high-performance liquid chromatography-mass spectrometry (HPLC-MS). The deposition rate of lycopene into egg yolk was approximately 2%, which was quantitatively determined using a HPLC with a UV detector. The result indicates that lycopene is a good candidate for egg yolk pigmentation and for making functional eggs.

곡류가공품 중 제랄레논 오염도 조사 (Analysis of Zearalenone Contamination in Cereal-Based Products Using High Performance Liquid Chromatography-Fluorescence Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry)

  • 장미란;이창희;최인선;신춘식;김진희;장영미;김동술;안동현
    • 한국식품과학회지
    • /
    • 제43권2호
    • /
    • pp.224-229
    • /
    • 2011
  • 시중 유통 중인 과자류, 빵, 떡류, 면류 및 선식 등 432건을 immunoaffinity column으로 정제하여 HPLC-FLD로 제랄레논에 대한 오염실태를 조사하였다. 제랄레논의 검량선은 결정계수($R^2$)가 0.999 이상으로 양호한 직선성을 보였고 검출한계 및 정량한계는 각각 2.0, $6.0{\mu}g/kg$, 회수율 80.2-98.4%이었으며 RSD가 0.82-6.40%로 양호한 재현성을 나타내었다. 제랄레논 모니터링 결과, 과자류 중 스낵과자류 66건 중 3건에서 $6.02-11.82{\mu}g/kg$ 검출되었고 비스킷 71건 중 2건에서는 $14.78-17.83{\mu}g/kg$ 검출되었다. 면류, 빵류 및 떡류에서는 제랄레논이 검출되지 않았으며 침출차 14건에서 최고 $53.76{\mu}g/kg$ 검출, 선식 24건 중 16건에서 가장 높은 검출율(66.7%)을 나타내었다. 전분 2건, 시리얼두유 1건에서 제랄레논이 각각 5.55-8.56, $10.26{\mu}g/kg$ 검출되었다. 제랄레논 모니터링 결과는 기준이 설정되어 있는 유럽연합(곡류분말: $75{\mu}g/kg$, 빵, 비스킷, 스낵, 아침식사대용 시리얼류: $50{\mu}g/kg$, 영아 및 유아용 시리얼류: $20{\mu}g/kg$) 기준이하의 수준이었으며 국내외 연구보고와 비교한 결과 낮거나 비슷한 수준으로 검토되었다. 연구결과 곡류가공품에 대한 제랄레논 오염수준은 높지 않았으나 지구 온난화로 기후변화에 민감한 곰팡이독소와 같은 자연독소의 발생 증가가 우려되므로 선제적으로 대응하는 안전관리가 요구된다.

식품중 발기부전 치료제 및 유사물질 함량에 관한 조사연구 (A Study on Contents of Anti-impotence drug/drug-like compounds in Food)

  • 홍해근;방선재;박광희;이인숙;박민정;박정화;김종찬
    • 환경위생공학
    • /
    • 제22권3호
    • /
    • pp.89-96
    • /
    • 2007
  • To determine 8 anti-impotence drug/drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil, aminotadalafil, pseudovardenafil and hongdenafil in foods, simultaneously, high performance liquid chromatography(HPLC) and liquid chromatography-mass spectrometry (LC/MS) were used. The HPLC/UV analysis was performed on a column of capcellpak $C_{18}$ with 0.1% sodium-1-hexansulfonate in 0.2M ammonium formate/acetonitrile as a mobile phase. Mass spectra of the compounds by LC/MS were investigated with SCAN mode(Mass range and Fragment voltage) and SIM(Selected Ion Monitoring) mode (Ion target and Fragment voltage). The results follow as; 1. The HPLC/UV analysis was detected from 5 out of 63 samples. The content of sildenafil was in the range of 32.80 ppm ${\sim}$ 60.13 ppm from 4 out of 5 samples. The contents of sildenafil, vardenafil, homosildenafil were in the range 47.14 ppm from 1 out of 5 samples. 2. The conformed result of LC/MS was equal of detected from 5 out of 63 samples in HPLC/UV analysis. An easily available, simultaneous determination of 8 standards in adulterated health related foods was established by using a combination of LC/MS methods.