• Title/Summary/Keyword: high isolation

Search Result 1,968, Processing Time 0.023 seconds

Designing Electronics for High Frequency Shock (고주파 충격에 의한 전자부품 고장 방지 설계)

  • Lee, Jong-Hak;Kang, Dong-Seok;Choi, Ji-Ho;Kang, Young-Sik;Lee, Chang-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.10
    • /
    • pp.700-706
    • /
    • 2015
  • In this study, stability designing electronics mounted on launch vehicle for shock load(low/high frequency band) could be derived. For the low-frequency shock loads, CCA(circuit card assembly) has secured the structural integrity over the best natural frequency techniques. For the high-frequency shock load, the structural integrity could be ensured with applying device such as the insulation pad. When the EAR is applied, insulation effect of part application is good more than whole application.

Isolation and purification of Cd-binding high molecular weight protein in rat liver(I) (흰쥐 간에서의 카드뮴 결합 고분자량 단백질의 분리 및 정제(I))

  • Chun, Ki-Jung;Kim, Bong-Hee
    • YAKHAK HOEJI
    • /
    • v.38 no.5
    • /
    • pp.608-613
    • /
    • 1994
  • We isolated two Cd-binding high molecular weight proteins from intraperitoneally cadmium injected rat liver. Molecular weight of Cd-BP(I) purified from Sephacryl S-100 and DEAE Sepharose column chromatography and Cd-BP(II) purified from DEAE Sepharose column chromatography and Sulphonyl Sepharose column chromatography was 33,000 and 18,400, respectively. Alcohol dehydrogenase and alkaline phosphatase acitivities were not detected from two purified proteins.

  • PDF

Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Nakajima, Shunsuke
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.219-227
    • /
    • 2021
  • This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.

Reducing Vibration of a Centrifugal Turbo Blower for FCEV Using Vibrational Power Flow (진동 동력 흐름 기법을 이용한 FCEV용 원심형 터보 블로워의 진동 저감)

  • Kim, Yoon-Seok;Lee, Sang-Kwon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.150-158
    • /
    • 2009
  • A centrifugal turbo blower is one of the part to generate electric power of fuel cell electric vehicle(FCEV). In order to generate the electric power of FCEV, the centrifugal turbo blower operates at very high speed above 30,000rpm in order to increase the pressure of the air, which supplied to a stack of FCEV, using rotation of its impeller blades. Vibration which originated from the blower is generated by unbalance of mechanical components, rotation of bearings and rotating asymmetry that rotate at high speed. The vibration is transmitted to receiving structure through vibration isolators and it can causes serious problems in the noise, vibration and harshness(NVH) performance. Thus, the study about reducing this kind of vibration is an important task. Quantifying the effectiveness of vibration isolation can be effectively accomplished by using vibrational power flow because relative contributions of each isolator to the total vibration transmission can be easily represented. In this paper, vibrational power flow is applied to the centrifugal turbo blower mounted on FCEV in order to analyze the most dominant vibration transmitting path. As a result, the main contributor among four isolators is a mount #3 of the blower. Also, a 30 percent lowering of the mount #3 stiffness shows 34 percent decrement of vibrational power flow by the simulation.

Prediction of Hydrofracture of Rock Salt under Ground at the Waste Isolation Pilot Plant (지하 핵 폐기물 저장 암염의 파괴현상 검증 및 분석)

  • Heo, Gwang-Hee;Lee, Cheo-Keun;Heo, Yol
    • Geotechnical Engineering
    • /
    • v.11 no.3
    • /
    • pp.139-162
    • /
    • 1995
  • The possibility of the development of gas driven hydrofractures at the Waste Isolation Pilot Plant(WIPP) is investigated through analytical and numerical calculations and through laboratory experiments. First, an investigation of the chemical reactions involved shows that a large volume of gas could potentially be generated through the oxidation of iron in the waste. Simple ground water'flow calculations then show that unless regions of high permeability has been created, this gas volume will build up the pressure high enough to cause tensile damage in the horizontal planes of weakness or in the halite itself. The analytical calculations were performed using the concepts of linear elastic fracture mechanics and the numerical calculations were done using the finite element method. Also, laboratory tests were conducted to illustrate possible failure mechanisms. It is possible that after growing horizontal crack in the weaker anhydride layer, the crack could break out of this layer and propagate upward into the halite and toward the ground surface at an inclined argle of around 53$^{\circ}$ above horizontal. To prevent this latter phenomenon the anhydrite must have a fracture toughness less than 0.5590 times than that of the halite. Through the tests, three types of crack(radial vertical cracks, horizontal circular cracks and cone -shaped cracks) were observed.

  • PDF

Nontyphoid Salmonella Prevalence, Serovar Distribution and Antimicrobial Resistance in Slaughter Sheep

  • Cetin, Ece;Temelli, Seran;Eyigor, Aysegul
    • Food Science of Animal Resources
    • /
    • v.40 no.1
    • /
    • pp.21-33
    • /
    • 2020
  • This study aimed to determine the current prevalence, serovar distribution and antimicrobial resistance rate and patterns of nontyphoid Salmonella (NTS) in slaughter sheep and their edible offal. While filling the gap of up to date related information in Turkey, data presented is also of significance since contamination of ovine meat, its products and offal with this pathogen is threat to public health due to their considerably high consumption rates in our country. Current NTS carriage in 200 apparently healthy slaughter sheep by ISO 6579:2002, 6579:2002/A1:2007 standard bacteriology (ISO) was 5% (10/200) (4 fecal content - 2%, 3 mesenterial lymph node - 1.5%, 3 kidney - 1.5%) out of 1,400 samples (0.7%), with no isolation from carcass, liver, gallbladder, spleen. Real-time PCR was in substantial agreement to ISO in confirming Salmonella-suspect isolates (Relative Trueness: 93.6%). S. Newport (40%) was the predominant serovar, followed by the second prevalent serovars as S. Typhimurium and S. Kentucky (20%), and by S. Umbilo and S. Corvallis (10%). Four and 6 out of 10 NTS isolates were susceptible (40%) and resistant (60%) to 18 antimicrobials, respectively. S. Typhimurium isolates were multidrug resistant (MDR) to tigecycline and sulphamethoxazole/trimethoprim, with one also resistant to cefepime. S. Corvallis was MDR to ampicillin, ciprofloxacin, norfloxacin and pefloxacin. The predominance of S. Newport and first isolation of S. Corvallis in sheep in the world; first time isolations of Newport, Kentucky, Corvallis, Umbilo serovars from sheep in Turkey; and high antimicrobial resistance rates obtained in majority of the isolates highlights study findings.

A Study on RF MEMS Switch with Comb Drive (Comb drive를 이용한 RF MEMS 스위치에 관한 연구)

  • Kang, Sung-Chan;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.4
    • /
    • pp.7-12
    • /
    • 2008
  • This paper presents a lateral resistive contact RF MEMS switch using comb drive. Our goal was to fabricate the RF MEMS switch with high reliability and good RF characteristics for front end module in wireless transceiver system. Therefore, comb drive is used for large contact force in order to achieve low insertion loss and small off-state capacitance in order to achieve high isolation. The single crystalline silicon is used for mechanical reliability. As a result, the developed switch showed insertion loss less than 0.44 dB at 2 GHz, isolation greater than 60 dB, and low actuation voltage at 26 V.

Isolation and Characterization of an Acyclic Isoprenoid from Semecarpus anacardium Linn. and its Antibacterial Potential in vitro - Antimicrobial Activity of Semecarpus anacardium Linn. Seeds -

  • Purushothaman, Ayyakkannu;Meenatchi, Packirisamy;Saravanan, Nallappan;Karuppaiah, Muthu;Sundaram, Ramalingam
    • Journal of Pharmacopuncture
    • /
    • v.20 no.2
    • /
    • pp.119-126
    • /
    • 2017
  • Objectives: Semecarpus anacardium Linn. is a plant well-known for its antimicrobial, antidiabetic and anti-arthritic properties in the Ayurvedic and Siddha system of medicine. This has prompted the screening of this plant for antibacterial activity. The main aims of this study were to isolate compounds from the plant's seeds and to evaluate their antibacterial effects on clinical bacterial test strains. Methods: The n-butanolic concentrate of the seed extract was subjected to thin layer chromatography (TLC) and repeated silica gel column chromatography followed by elution with various solvents. The compound was identified based on observed spectral (IR, $^1H$ NMR, $^{13}C$ NMR and high-resolution mass spectrometry) data. The well diffusion method was employed to evaluate the antibacterial activities of the isolated acyclic isoprenoid compound (final concentration: $5-15{\mu}g/mL$) on four test bacterial strains, namely, Staphylococcus aureus (MTCC 96), Bacillus cereus (MTCC 430), Escherichia coli (MTCC 1689) and Acinetobacter baumannii (MTCC 9829). Results: Extensive spectroscopic studies showed the structure of the isolated compound to be an acyclic isoprenoid ($C_{21}H_{32}O$). Moreover, the isoprenoid showed a remarkable inhibition of bacterial growth at a concentration of $15{\mu}g/mL$ compared to the two other doses tested (5 and $10{\mu}g/mL$) and to tetracycline, a commercially available antibiotic that was used as a reference drug. Conclusion: The isolation of an antimicrobial compound from Semecarpus anacardium seeds validates the use of this plant in the treatment of infections. The isolated compound found to be active in this study could be useful for the development of new antimicrobial drugs.

DESIGN AND FABRICATION OF S-BAND DIPLEXER FOR LEO TT&C APPLICATION (저궤도 위성 관제용 S-대역 다이플렉서 설계 및 제작)

  • Ahn, Sang-Il;Park, Dong-Chul
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.397-408
    • /
    • 2007
  • Diplexer is one of core devices needed to communicate with satellite using single ground antenna by separating uplink and downlink signal. This paper presents the design of the S-band diplexer for LEO TT&C application, especially for KOMPSAT (KOrea Multi-Purpose SATellite). To cope with requirements such as high handling power, low insertion loss, air-cavity resonator with high quality factor was considered as one of design drivers. Design was started with predicting unloaded Q and equivalent circuit from the structure of air-cavity resonator. For the convenience of adjustment, the coupling factor placed between resonators was estimated from COTSEM (Electro-Magnetic) simulator, EESOF $ADS^{TM}$, and expressed with 2-order polynomial regression. To improve the isolation between transmitting part (Tx) and receiving part (Rx), the inductive and capacitive attenuation poles were inserted between $4^{th}\;and\;6^{th}$ resonator respectively. The fabricated diplexer consists of two bandpass filters and each filter has eight resonants. From the measurement, it was shown that major requirements such as 0.5dB of insertion loss, 20dB of return loss and 100dB of isolation were fully satisfied within passband.

New Isolated Zero Voltage Switching PWM Boost Converter (새로운 절연된 영전압 스위칭 PWM 부스트 컨버터)

  • Cho, Eun-Jin;Moon, Gun-Woo;Jung, Young-Suk;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.535-538
    • /
    • 1994
  • In this paper, an isolated ZVS-PWM boost converter is proposed for single stage line conversion. For power factor correction, we used the half bridge topology at the primary side of isolation transformer permitting switching devices to operate under ZVS by using circuit parastics and operating at a fixed duty ratio near 50%. Thus the relatively continuous input current distortion and small size input filter are also achievable. The ZVS-PWM boost operation of the proposed converter can be achieved by using the boost inductor $L_f$, main switch $Q_3$, and simple auxiliary circuit at the secondary side of isolation transformer. The secondary side circuit differ from a conventional PWM boost converter by introduction a simple auxiliary circuit. The auxiliary circuit is actived only during a short switching transition time to create the ZVS condition for the main switch as that of the ZVT-PWM boost converter. With a single stage, it is possible to achieve a sinusoidal line current at unity power factor as well as the isolated 48V DC output. Comparing to the two stage schemes, overall effiency of the proposed converter is highly improved due to the effective ZVS of all devices as well as single stage power conversion. Thus, it can be operated at high switching frequency allowing use of small size input filter. Minimum voltage and current stress make it high power application possible.

  • PDF