• Title/Summary/Keyword: height-to-width ratio

Search Result 490, Processing Time 0.02 seconds

Improving the seismic behavior of diagonal braces by developing a new combined slit damper and shape memory alloys

  • Vafadar, Farzad;Broujerdian, Vahid;Ghamari, Ali
    • Structural Engineering and Mechanics
    • /
    • v.82 no.1
    • /
    • pp.107-120
    • /
    • 2022
  • The bracing members capable of active control against seismic loads to reduce earthquake damage have been widely utilized in construction projects. Effectively reducing the structural damage caused by earthquake events, bracing systems equipped with retrofitting damper devices, which take advantage of the energy dissipation and impact absorption, have been widely used in practical construction sites. Shape Memory Alloys (SMAs) are a new generation of smart materials with the capability of recovering their predefined shape after experiencing a large strain. This is mainly due to the shape memory effects and the superelasticity of SMA. These properties make SMA an excellent alternative to be used in passive, semi-active, and active control systems in civil engineering applications. In this research, a new system in diagonal braces with slit damper combined with SMA is investigated. The diagonal element under the effect of tensile and compressive force turns to shear force in the slit damper and creates tension in the SMA. Therefore, by creating shear forces in the damper, it leads to yield and increases the energy absorption capacity of the system. The purpose of using SMA, in addition to increasing the stiffness and strength of the system, is to create reversibility for the system. According to the results, the highest capacity is related to the case where the ratio of the width of the middle section to the width of the end section (b1/b) is 1.0 and the ratio of the height of the middle part to the total height of the damper (h1/h) is 0.1. This is mainly because in this case, the damper section has the highest cross-section. In contrast, the lowest capacity is related to the case where b1/b=0.1 and the ratio h1/h=0.8.

Verification of Computational Fluid Dynamics Model Using Observation Data in Artificial Street Canyon (인공 도로협곡 관측 자료를 활용한 전산유체역학모델 검증)

  • Kim, Do-Hyoung;Hong, Seon-Ok;Lee, Dae-Geun;Lee, Young-Gon;Kim, Baek-Jo
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.423-433
    • /
    • 2016
  • In this study, performance of a computational fluid dynamics (CFD) model is assessed from analysis on air flow pattern which is observed in the artificial street canyon. Field observations focusing on flows were conducted at an artificial street canyon in Magok region. For the observation of three-dimensional airflow structures, twelve three-dimensional wind anemometers (hereafter, CSAT3) were installed inside the street canyon. The street canyon was composed of two rectangular buildings with 35-m length, 4-m width, and 7-m height. The street width (distance between the buildings) is 7 m, making the street aspect ratio (defined by the ratio of building height to street width) of 1. For the observation of above-building wind, a CSAT3 was installed above the northwest-side building. Southwesterly, westerly and northwesterly were dominant in the street canyon during the observations. Because wind direction is parallel to the street canyon in the southwesterly case, westerly and northwesterly were selected as inflow directions in numerical simulations using a computational fluid dynamics model developed through the collaborative research project between National Institute of Meteorological Sciences and Seoul National University (CFD_NIMR_SNU). The observations showed that a well-structured vortex flow (skimming flow) and an evidence of a small eddy at the corner of the downwind building and ground appeared. The CFD_NIMR_SNU reproduced both the observed flow patterns reasonably well, although wind speeds inside the street canyon were underestimated.

Impact of Fin Aspect Ratio on Short-Channel Control and Drivability of Multiple-Gate SOI MOSFET's

  • Omura, Yasuhisa;Konishi, Hideki;Yoshimoto, Kazuhisa
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.4
    • /
    • pp.302-310
    • /
    • 2008
  • This paper puts forward an advanced consideration on the design of scaled multiple-gate FET (MuGFET); the aspect ratio ($R_{h/w}$) of the fin height (h) to fin width (w) of MuGFET is considered with the aid of 3-D device simulations. Since any change in the aspect ratio must consider the trade-off between drivability and short-channel effects, it is shown that optimization of the aspect ratio is essential in designing MuGFET's. It is clearly seen that the triple-gate (TG) FET is superior to the conventional FinFET from the viewpoints of drivability and short-channel effects as was to be expected. It can be concluded that the guideline of w < L/3, where L is the channel length, is essential to suppress the short-channel effects of TG-FET.

A Study on Variation of Ultimate Pullout Resistance and Failure Behavior for Vertical Plate Anchors in Sands (앵커의 극한 지지력 변화와 파괴 거동에 관한 연구)

  • 장병욱;황명수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.4
    • /
    • pp.71-80
    • /
    • 1990
  • Model tests for the ultimate pullout resistance of anchorages and investigation of failure behaviors in cohesionless soil have been conducted. The factors affecting the anchorage are mostly the geometry of the system, and soil properties of sands. The main conclusions of the experimental work were as follows. 1. The load - displacement relationship can be a form of parabolic curve for all plates. 2. The change in ultimate pullout resistance of anchor is mostly affected by embedment ratio and size of anchor, and influenced to a lesser degree by its shape. 3. Critical embedment ratio which is defined as the failure mode changes from shallow to deep mode is increased with increasing height of anchor. 4. For a constant anchor height, as the width of anchor increases the ultimate pullout resistance also increases. However, considering the efficiency of anchor for unit area, width of anchor does not appear to have any sigrnificant contribution on increasing anchor city. 5. Anchor capacity has a linear relation to sand density for any given section and the rate of change increases as the section increases. Critical depth determining the failure patterns of anchor is decreased with a decrease of sand density. 6. With increasing inclination angle, size of anchor, and decreasing embedment ratio, the ultimate pullout resistance of anchor under inclined loading is significantly decreased. 7. The ultimate pullout resistance of double anchor, a method of improving single of anchor capacity, is influenced by the center - to - center spacing adjacent anchors. It is also found that tandem and parallel anchor rigging arrangements decrease the anchor system capacity to less than twice the single anchor capacity due to anchor interference.

  • PDF

A Study on the Reduction of the Sloshing of Storage Tank Using Wing and Diaphragm Baffle (날개형 및 격막형 배플을 이용한 유체저장탱크 내부의 슬로싱 저감 연구)

  • Lee, Young-Shin;Kim, Hyun-Soo;Lee, Jae-Hyung;Kim, Young-Wann;Ko, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.12
    • /
    • pp.2039-2046
    • /
    • 2003
  • Storage tank filled with fluid has unique dynamic characteristics compared to general structures, due to the interaction between fluid and structure. The oscillation of the fluid surface caused by external forces is called sloshing, which occurs in moving vehicles with contained liquid masses, such as trucks, railroad cars, aircrafts, and liquid missles. In this study, the evaluation method for the reduction of sloshing, the optimized size and location of wing and diaphragm baffles are suggested based on the experimental results. The experimental device can simulate the translation motion. A rectangular tank and various baffles are fabricated to study on the sloshing characteristics. The forces measured using the load cell at tank wall and those are compared with each other through the Fourier transformation for various conditions. The study of the sloshing of the rectangular tank equipped with baffles is conducted under the same conditions with non-baffled rectangular tank experiment. From the experimental results, the sloshing reduction effect by the baffles is observed. In conclusion in case of diaphragm baffles, the optimized size ratio of the width of baffle to the water height is 0.44 and the installation location has no effect to the damping of sloshing. In case of wing baffles, the optimized size ratio of the width of baffle to the length of a rectangular tank is 0.1 and the optimized location ratio of the baffle to the water height is 0.9.

Posteroanterior cephalometric characteristics in skeletal Class III malocclusion (골격성 III급 부정교합자의 정모 두부규격방사선 계측학적 특징)

  • Chong, Song-Woo;Hong, Sung-Gyu;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.29 no.3 s.74
    • /
    • pp.317-325
    • /
    • 1999
  • In proper diagnosis of skeletal Class III malocclusion, it was important to know the pattern of three dimensional skeletal & facial disharmony. The purpose of this study was to obtain P-A cephalometric characteristics in skeletal Class III malocclusion comparing with normal occlusion. The samples were consisted of 120 subjects, divided into four groups : Male normal occlusion, Female normal occlusion, Male skeletal Class III malocclusion, Female skeletal Class III malocclusion. Posteroanterior and lateral cephalogram were taken from the subjects with a x-ray apparatus (ASHAI CX90SP, Japan) and traced on acetate paper with routine manner. The transverse and vertical values from posteroanterior cephalometry, the sagittal values from lateral cephalometry and their ratio were obtained. The results were as follows: 1. The anteroposterior discrepancy in skeletal Class III group was not due to short maxillary length(Cd-A), but to longer mandibular length(Cd-Gn) than normal occlusion group. 2. The faces of skeletal Class III group were longer than normal occlusion group. It was not due to increase of upper face height(Cg-ANS) but to increase of the lower face height(ANS-Me) especially mandibular height(Cd-Me). 3. There was no difference in the facial width values between normal occlusion group and skeletal Class III group, except upper molar width(U6-U6), lower molar width(L6-L6) and mandibular width(Ag-Ag) of female skeletal Class III group which were larger than normal occlusion group. 4. The increase of mandibular length of skeletal Class III group was reflected in the increase of lower facial height but did not have an effect on the mandibular width.

  • PDF

A Numerical Study on the Heat Transfer Characteristics of the Multiple Slot Impinging Jet (다양한 노즐 수 변화에 따른 충돌 제트의 열전달 특성에 관한 수치적 연구)

  • Kim, Sang-Keun;Ha, Man-Yeong;Son, Chang-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.754-761
    • /
    • 2011
  • The present study numerically investigates two-dimensional flow and heat transfer in the multiple confined impinging slot jet. Numerical simulations are performed for the different Reynolds numbers(Re=100 and 200) in the range of nozzles from 1 to 9 and height ratios(H/D) from 2 to 5, where H/D is the ratio of the channel height to the slot width. The vector plots of velocity profile, stagnation and averaged Nusselt number distributions are presented in this paper. The dependency of thermal fields on the Reynolds number, nozzle number and height ratio can be clarified by observing the Nusselt number as heat transfer characteristic at the stagnation point and impingement surface. The Nusselt number at the stagnation point of the central slot shows unsteadiness at H/D=3 and Re=200. The value of Nusselt number at the stagnation point of the central slot decreases with higher Reynolds number and number of nozzle although overall area averaged Nusselt number increases. Hence careful selection of geometrical parameters and number of nozzle are necessary for optimization of the heat transfer performance of multiple slot impinging jet.

A Study on the Coupling of a Flanged Parallel-Plate Waveguide to a Nearby Conducting Strip from the Viewpoint of Near-Field Scanning Microscopy (근접주사현미경의 관점에서 플랜지된 평행평판 도파관과 근접도체스트립과의 결합에 관한 연구)

  • Lee, Jong-Ig;Ko, Ji-Hwan;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2260-2266
    • /
    • 2009
  • In this paper, the problem of electromagnetic coupling between a slit fed by a flanged parallel-plate waveguide (FPPW) and a nearby conducting strip parallel to the slit is studied as a simplified problem for a near-field scanning microscopy (NSM). The characteristics of the FPPW are investigated from the results for the variations of the equivalent slit admittance, the reactive powers near the slit inside and outside the FPPW, the magnitude and phase of the voltage reflection coefficient of the TEM wave. The performance of the proposed apparatus as an NSM is tested by examining the effects of various geometrical parameters such as guide height, slit width, strip width, distance between slit and strip, and the ratio of slit width to guide height on the magnitude and phase of the voltage reflection coefficient of the TEM wave. From the results for the voltage reflection coefficient against the strip offset from the slit, it is found that a slit in the FPPW with smaller guide height gives higher scanning resolution and the phase variation is more sensitive than the magnitude variation.

Potential Change in the Cross Section of the Rectangular Microchannel with Different Hydraulic Diameters (수력학적 지름 변화에 따른 직사각형 마이크로채널 단면에서의 파텐셜 변화)

  • Lee, Hyo Song;Kim, Ki Ho;Yu, Jae Keun;Noh, Soon Young;Choi, Jae Ho;Yoon, Soo Kyung;Rhee, Young Woo
    • Clean Technology
    • /
    • v.12 no.4
    • /
    • pp.211-216
    • /
    • 2006
  • In this study, we investigated the potential changes in the cross sectional area of the rectangular microchannel with various zeta potentials and hydraulic diameters. We changed height/width ratio as 1, 1/2, and 1/3 and investigated its effect on the potential change. For this research, FEMLAB(Comsol, verson 3.0) was used to investigate the theoretical potential distribution. The potential changes in the cross section shows that right and left surfaces affect to some ranges. For the same area and shape, the potential value is directly proportional to the zeta potential change. With the decrease in the H/W ratio, the electrical double layer is condensed to the side surfaces.

  • PDF

Effect of Duct Aspect Ratios on Pressure Drop in a Rotating Two-Pass Duct (덕트 종횡비가 회전덕트 내 압력강하에 미치는 영향)

  • Kim Kyung-Min;Lee Dong-Hyun;Cho Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.505-513
    • /
    • 2006
  • The pressure drop characteristics in a rotating two-pass duct with rib turbulators are investigated in the present study. Three ducts of different aspect ratios (W/H=0.5, 1.0 and 2.0) are employed with a fixed hydraulic diameter ($D_h$) of 26.7 mm. $90^{\circ}$-rib turbulators with $1.5mm{\times}1.5mm$ cross-section are attached on the leading and trailing surfaces. The pitch-to-rib height ratio (p/e) is 1.0. The distance between the tip of the divider and the outer wall of the duct is 1.0 W. The thickness of divider wall is 6.0 mm o. 0.225 $D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000 and the .elation number (Ro) is varied from 0.0 to 0.2. As duct aspect ratio increases, high friction factor ratios show in overall regions. The reason is that the rib height-to-duct height ratio (e/H) increases, but the divider wall thickness-to-duct width ($t_d/W$) decreases. The rotation of duct produces pressure drop discrepancy between the leading and trailing surfaces. However, the pressure drop discrepancy of the high duct aspect ratio (AR=2.0) is smaller than that of the low duct aspect ratio (AR=0.5) due to the decrement of duct hight (H).