• 제목/요약/키워드: heavy ion beam

검색결과 69건 처리시간 0.028초

Control the length of beam trajectory with a quadruple triplet for heavy ion accelerator

  • Wei, Shaoqing;Zhang, Zhan;Lee, Sangjin;Kim, Do Gyun;Kim, Jang Youl
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권4호
    • /
    • pp.40-43
    • /
    • 2016
  • Beam trajectory is needed to be controlled in heavy ion accelerator system. Quadruple magnets are widely used in heavy ion accelerator for focusing the transporting particles. A quadruple triplet system which consists of three consecutive quadrupoles, Q1, Q2 and Q3, is used to control beam trajectory at a focused position. Q1 and Q3 have symmetry with respect to Q2. The beam trajectory in magnet system is affected by higher order fields existed in real fields. For quadrupoles, the representation simulation of beam trajectory was carried out to study the beam trajectory and to estimate an effect of higher order field in triplet system. SCALA program was used to simulate the beam trajectory in $Opera^{TM}$. SCALA can analyze a large number of beam trajectories at the same time by adjusting the size of finite element of the emitter. With $Opera^{TM}$ and $Matlab^{TM}$ programs, the position of focused beam spot in quadruple triplet system can be increased or decreased using evolution strategy (ES) method, therefore the length of triplet system can be controlled. Finally, the quadruple triplet system with the appropriate length and expected beam spot range was suggested in this paper.

Influences of the Irradiation of Intense Pulsed ion Beam (IPIB) on the Surface of Ni$_3$Al Base Alloy IC6

  • Le, X.Y.;Yan, S.;Zhao, W.J.;Han, B.H.;Wang, Y.G.;Xue, J.M.;Zhang, H.T.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권2호
    • /
    • pp.92-96
    • /
    • 2002
  • In this paper, we treated the Ni$_3$Al based alloy samples with intense pulsed ion beams (IPIB) at the beam parameters of 250KV acceleration voltage, 100 - 200 A/cm$^2$ current density and 60 u pulse duration. We simulated the thermal-mechanical process near the surface of Ni$_3$Al based alloy with our STEIPIB codes. The surface morphology and the cross-section microstructures of samples were observed with SEM, the composition of the sample surface layer was determined by X-ray Energy Dispersive Spectrometry (XEDS) and the microstructure on the surface was observed by Transmission Electron Microscope (TEM). The results show that heating rate increases with the current density of IPIB and cooling rate reached highest value less than 150 A/cm$^2$. The irradiation of IPIB induced the segregation of Mo and adequate beam parameter can improve anti-oxidation properly of IC6 alloy. Some craters come from extraneous debris and liquid droplets, and some maybe due to the melting of the intersection region of interphase. Increasing the pulse number enlarges average size of craters and decreases number density of craters.

  • PDF

중이온 Beam 조사가 담배 (Nicotiana tabacum L. cv. BY-4)의 약과 캘러스 및 종자에 미치는 영향 (Effect of a Heavy-lon Beam Irradiation on Anthers, Calli and Seeds of Tobacco (Nicotiana tabacum L. cv. BY-4))

  • 배창휴;;김동철;이영일;정재성;민경수;이효연
    • 식물조직배양학회지
    • /
    • 제27권2호
    • /
    • pp.109-115
    • /
    • 2000
  • 배양 중인 담배의 약과 캘러스, 그리고 종자에 중이온 ($^{14}$ N 또는 $^{20}$ Ne) beam을 조사하여 중이온 beam 조사가 약의 반응, 캘러스의 생장, 종자의 발아와 초기 생장에 미치는 영향을 조사하였다. 중이온 beam을 조사하기 전 10일간 preculture한 다음 beam을 조사한 약은 $^{14}$ N, $^{20}$ Ne 모두 20Gy 이상의 선량에서 캘러스 또는 신초유도가 없이 고사하였다. 배양 중인 캘러스는 $^{14}$ N 와 $^{20}$ Ne 이온 beam의 조사로 상대생장율이 감소하였고, 중이온 beam 조사 2주 후부터는 50 Gy 이상 선량 처리구에서 심하게 갈변하였다. 종자에 미치는 중이온 beam 조사의 영향으로 수분을 처리한 후 또는 수분 처리 없이 beam을 조사한 종자 모두에서 선종에 관계없이 선량이 증가함에 따라 발아를 지연시키며 유묘의 초기 생장을 억제하였다. 또한 수분을 흡수시킨 후 중이온 beam을 조사한 경우가 수분을 흡수시키지 않고 beam을 조사한 경우 보다 종자의 발아를 심하게 억제시켰다. 건조 상태의 종자에 중이온 beam을 조사한 경우 피조사체들의 특성과 생장의 초기단계에서 형태적 변이체를 검토하는데는 여과지를 이용한 방법보다 기내에서 배양하는 방법이 보다 효과적이었다.

  • PDF

Monte Carlo Calculation for Production Cross-Sections of Projectile's Isotopes from Therapeutic Carbon and Helium Ion Beams in Different Materials

  • Quazi Muhammad Rashed Nizam;Asif Ahmed;Iftekhar Ahmed
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.204-212
    • /
    • 2023
  • Background: Isotopes of the projectile may be produced along the beam path during the irradiation of a target by a heavy ion due to inelastic interactions with the media. This study analyzed the production cross-section of carbon (C) and Helium (He) projectile's isotopes resulting from the interactions of these beams with different materials along the beam path. Materials and Methods: In this study, we transport C and He ion beams through different materials. This transportation was made by the Monte Carlo simulation. Particle and Heavy Ion Transport code System (PHITS) has been used for this calculation. Results and Discussion: It has been found that 10C, 11C, and 13C from the 12C ion beam and 3He from the 4He ion beam are significant projectile's isotopes that have higher flux than other isotopes of these projectiles. The 4He ion beam has a higher projectile's isotope production cross-section along the beam path, which adds more impurities to the beam than the 12C ion beam. These projectile's isotopes from both the 12C and 4He ion beams have higher production cross-sections in hydrogenous materials like water or polyethylene. Conclusion: It is important to distinguish these projectile's isotopes from the primary beam particles to obtain a precise and accurate cross-section result by minimizing the error during measurement with a nuclear track detector. This study will show the trend of the production probability of projectile's isotopes for these ion beams.

Profile and Dose Distribution for Therapeutic Heavy Ion Beams

  • Sasaki, Hitomi;Komori, Masataka;Kohno, Toshiyuki;Kanai, Tatsuaki;Hirai, Masaaki;Urakabe, Eriko;Nishio, Teiji
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.211-213
    • /
    • 2002
  • The purpose of this work is acquiring some parameters of therapeutic heavy ion beams after penetrating a thick target. The experiments were performed using a pencil-like $\^$12/C beam of about 3 mm in diameter from NIRS-HIMAC, and the data were taken at several points of the target thickness for $\^$12/C beam of 290 MeV/u and 400 MeV/u. By the simultaneous measurements using some detectors, the atomic number of each fragment particle was identified, and the beam profile, the dose distribution and the LET spectrum for each element were derived.

  • PDF

Target Size Dependence of Spatial Resolution in Heavy Ion CT

  • Ohno, Yumiko;Kohno, Toshiyuki;Kanai, Tatsuaki;Sasaki, Hitomi;Nanbu, Syuya
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.94-96
    • /
    • 2002
  • In order to achieve the radiotherapy more precisely using highly energetic heavy charged particles, it is important to know the distribution of the electron density in a human body, which is highly related to the range of charged particles. We can directly obtain the 2-D distribution of the electron density in a sample from a heavy ion CT image. For this purpose, we have developed a heavy ion CT system using a broad beam. The performance, especially the position resolution, of this system is estimated in this work. All experiments were carried out using the heavy ion beam from the HIMAC. We have obtained the projection data of polyethylene samples with various sizes using He 150 MeV/u, C 290 MeV/u and Ne 400 MeV/u beams. The used targets are the cylinders of 40, 60 and 80 mm in diameter, each of them has a hole of 10 mm in diameter at the center of it. The dependence of the spatial resolution on the target size and the kinds of beams will be discussed.

  • PDF

Design study of the Vacuum system for RAON accelerator using MonteCarlo method

  • 김재홍;전동오
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.70.1-70.1
    • /
    • 2015
  • The facility for RAON superconducting heavy-ion accelerator at a beam power of up to 400 kW will be produced rare isotopes with two electron cyclotron resonance (ECR) ion sources. Highly charged ions generated by the ECR ion source will be injected to a superconducting LINAC to accelerate them up to 200 MeV/u. During the acceleration of the heavy ions, a good vacuum system is required to avoid beam loss due to interaction with residual gases. Therefore ultra-high vacuum (UHV) is required to (i) limit beam losses, (ii) keep the radiation induced within safe levels, and (iii) prevent contamination of superconducting cavities by residual gas. In this work, a RAON vacuum design for all the accelerator system will be presented along with Monte Carlo simulation of vacuum levels in order to validate the vacuum hardware configuration, which is needed to meet the baseline requirements.

  • PDF

A calculation on the Metal-Film Mixing by Intense Pulse Ion Beam (IPIB)

  • Le, X.Y.;Yan, S.;Zhao, W.J.;Wang, Y.G.;Xue, J.M.
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.74-78
    • /
    • 2003
  • In this paper, we studied, by numerical calculation, a system, which was composed of metal-film and metal-substrate irradiated by IPIB with beam ion energy 250 keV, current density 10 to 250 A/$\textrm{cm}^2$. While the IPIB irradiation was going on, an induced effect named mixing occurred. In this case, metal-film and part of metal-substrate melted and mixed. The mixing state was kept as it was in melting phase due to the fast cooling rate. Our works were simulating the heating and cooling process via our STEIPIB program and tried to find proper parameters for a specific film-substrate system, 500 nmtitanium film coated on aluminum, to get best mixing results. The parameters calculated for such Ti-Al system were compared with the experimental results and were in good accordance to the experimental results.

중이온 빔조사 담배(Nicotiana plumbaginifolia) 식물체의 생장과 DNA 변이 (Growth and DNA Alteration of Heavy-ion Beam Irradiated Tobacco(Nicotiana plumbaginifolia) Plant)

  • 류재일;김민수;;이효연;양덕춘;배창휴
    • 한국자원식물학회지
    • /
    • 제18권1호
    • /
    • pp.169-178
    • /
    • 2005
  • 중이온빔$(^{20}Ne)$을 담배 식물체에 조사(irradiation)하여 식물체의 생장과 DNA의 변이에 미치는 영향을 검토하였다. 발아율과 초장은 조사선 량이 증가함에 따라 감소하였다. 반면 $50Gy\~10Gy$의 저선량에서 추대와 개화가 촉진되어 발육은 오히려 촉진되었다. 총 100개의 primer를 이용하여 RAPD분석한 결과, 59개의 primer에서 총 336개의 DNA단편이 증폭되었고, 1개의 primer에서 중이온빔 조사처리구에서만 출현하는 DNA단편이 나타났다. AFLP분석 결과, 개체 특이적인 DNA단편은 나타난 반면 중이온빔 처리구 특이적인 DNA 단편은 관찰되지 않았다.

Carbon Ion Therapy: A Review of an Advanced Technology

  • Kim, Jung-in;Park, Jong Min;Wu, Hong-Gyun
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.71-80
    • /
    • 2020
  • This paper provides a brief review of the advanced technologies for carbon ion radiotherapy (CIRT), with a focus on current developments. Compared to photon beam therapy, treatment using heavy ions, especially a carbon beam, has potential advantages due to its physical and biological properties. Carbon ion beams with high linear energy transfer demonstrate high relative biological effectiveness in cell killing, particularly at the Bragg peak. With these unique properties, CIRT allows for accurate targeting and dose escalation for tumors with better sparing of adjacent normal tissues. Recently, the available CIRT technologies included fast pencil beam scanning, superconducting rotating gantry, respiratory motion management, and accurate beam modeling for the treatment planning system. These techniques provide precise treatment, operational efficiency, and patient comfort. Currently, there are 12 CIRT facilities worldwide; with technological improvements, they continue to grow in number. Ongoing technological developments include the use of multiple ion beams, effective beam delivery, accurate biological modeling, and downsizing the facility.