• Title/Summary/Keyword: heating time and temperature

Search Result 1,378, Processing Time 0.03 seconds

Changes in Physicochemical Compounds with Heating Treatment of Ginseng (가열처리에 따른 인삼의 이화학적 성분변화)

  • Yoon, Sung-Ran;Lee, Myung-Hee;Park, Jung-Hyun;Lee, In-Seon;Kwon, Joong-Ho;Lee, Gee-Dong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.10
    • /
    • pp.1572-1578
    • /
    • 2005
  • Response surface methodology was used for monitoring changes in physicochemical properties with heating condition of ginseng which was sliced and freeze-dried. As heating temperature and time increased, soluble solid content decreased and browning color increased. Also, acidic polysaccharide and total phenolics increased with the increase in heating temperature and time. Heating condition for maximum soluble solid content was 146.05$^{\circ}C$ in heating temperature and 18.16 min in heating time. Maximum value of crude saponin content was 64.40 mg/g in 160.00$^{\circ}C$ and 20.00 min. Crude saponin content was influenced by heating time but the other properties were influenced by heating temperature.

The Effects of Operating and Design Conditions on the Performance of Radiant Heating Panel (복사 난방 패널의 공급유량 및 설계변수가 성능에 미치는 영향)

  • Lee, Tae Won;Kim, Ho Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.276-285
    • /
    • 1991
  • The transient heat transfer characteristics in the radiant heating panel were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with respect to time were obtained. Heating hours per day, rate of energy supplied and maximum temperature differences at panel surface were also compared for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various operating and design conditions such as pipe pitch, pipe location, pipe diameter and flow rate of hot water for the purpose of producing useful data, which can be used for the test and decision of efficient operating condition of the conventional heating systems or the optimal design of the new panel heating systems.

  • PDF

Strategy to Maintain the Smith Predictor Controller in the District Heating System for Apartment Buildings (지역난방 공동주택 시스템에서 Smith Predictor 제어기 적용성 연구)

  • Jung, Sang-Hoon;Moon, Youn-Jin;Ha, Jae-Sun;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1025-1030
    • /
    • 2009
  • It is known that the classical tuning formula for typical PID controllers in general provides unsatisfactory results for industrial plants where the time delay exceeds the dominant lag time. For this reason, alternative strategies have been studied in order to cope with this problem and the most popular scheme is the Smith Predictor(SP). In this paper, the dynamic model of a unit apartment in the district heating system, which is the control process effected by the dead-time, is developed, and the on/off room temperature control method with the SP simulate using Matlab-Simulink. The simulation results show that the SP works effectively in outdoor temperature variation.

  • PDF

The Analysis of Minerals and Free Amino Acid in Brown Stockwith Extracted Methods Varied (추출방법을 달리한 브라운 스톡의 무기질 및 유리아미노산 분석)

  • Jang, Hyuk-Rae;Lee, Bo-Soon;Choi, Soo-Keun
    • Culinary science and hospitality research
    • /
    • v.14 no.3
    • /
    • pp.210-222
    • /
    • 2008
  • This study showed that the brown stock, which is the base of demi-glace sauce, extracted by using a high pressure heating extractor is more advantageous than that extracted by the traditional extraction method for the mass production. We compared the former with the latter in terms of minerals and free amino acids. The results of this study are summarized as follows. When mineral contents were compared, the brown stock extracted by high.pressure heating extraction showed the tendency of increase in mineral contents in proportion to heating temperature and heating time, but, from extraction temperature of 140$^{\circ}C$, the contents of K, Mg, Na and P decreased with the increase of extraction time. In addition, mineral contents in the brown stock extracted by high-pressure heating extraction were generally lower than those in brown stock extracted by the traditional extraction method. This result was produced probably because materials were added repeatedly in the traditional method. Amino acids contents in brown stock according to the extraction methods were also examined. They increased with the increase in the number of extractions in the brown stock extracted by the traditional method, and those in the brown stock extracted using a high pressure heating extractor increased with the increase in heating temperature and extraction time. The results of this study are expected to be useful as a practical material for the mass production of brown stock products.

  • PDF

An Experimental Study of Moxa-Combustion Time by the Density of Moxa Material -On the point of time in the combustion stage- (애구(艾灸)의 연소(燃燒) 시간(時間)에 대한 실험적(實驗的) 연구(硏究) -구간별(區間別) 발현(發現) 시점(時點)을 중심(中心)으로-)

  • Park, Young-Bae;Kang, Sung-Keel;Koh, Hyung-Kyun;Oh, Hwan-Sup
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.241-252
    • /
    • 1994
  • It is known that the pattern of combustion temperature can be classified into preheating, heating. retaining and cooling periods. In this experiment. the authors have studied the heating mechanism by the density of moxa material during the heating and retaining periods. The starting point. the point at which it begins to reach the maximum gradient temperature. the ending point of the heating period. and the ending point of the retaining period were measured in order to get effective stmulation by repetition of moxa-combustion. For the experiment. samples of 300mg. 400mg, and 500mg of moxa material were molded into conical molds with each 10mm in diameter and height resulting in the volume of $0.26cm^3$. The following results were obtained: The $300mg/0.26cm^3$ denstiy sample reached al1 points tested faster than the samples of $400mg/0.26cm^3$ and $500mg/0.26cm^3$ It dose not reveal any statistical differences between $400mg/0.26cm^3$ and $500mg/0.26cm^3$ in the ending point. the point at which it begins to reach the maximum gradient temperature of the heating period or the ending point of the reataining period The only difference shown was in the starting point of the heating period. According to the above results. it is concluded that the lower density moxa material reached each point of the the respective period faster than the high density moxa material.

  • PDF

Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House (컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

Effects of Quasi-Carbonization Process on the Mechanical Properties of Spun Yarn Type Quasi-Carbon Fabrics

  • Donghwan Cho;Lee, Jongmoon;Park, Jon-Kyoo
    • Macromolecular Research
    • /
    • v.10 no.6
    • /
    • pp.318-324
    • /
    • 2002
  • In this paper we have extensively studied what and how processing parameters for quasi-carbonization influence the breaking strength and modulus of resulting quasi-carbon fabrics that are prepared from stabilized PAN fabrics with a spun yarn texture. Seven processing parameters have been considered as follows: applied tension, final heat-treatment temperature, heating rate, heating step, holding time, cooling rate, and purging gas purity. The results indicate that optimal uses of applied tension, final heat-treatment temperature, heating rate, and heating step during quasi-carbonization process are primarily important to increase the tensile properties of quasi-carbon fabrics and holding time, cooling rate, and purging gas purity are less importantly contributed.

A Study on the Estimation of Electricity Demand for Heating and Cooling using Cross Temperature Response Function (교차기온반응함수로 추정한 전력수요의 냉난방 수요 변화 추정)

  • Park, Sung Keun;Hong, Soon Dong
    • Environmental and Resource Economics Review
    • /
    • v.27 no.2
    • /
    • pp.287-313
    • /
    • 2018
  • This paper measures and analyzes cooling and heating demand in Korean electricity demand using time-varying temperature response functions and cooling and heating temperature effects. We fit the model to Korean data for residential and commercial sector over 1999:01~2016:12 and the estimation results show that the growth rate of heating demand is much higher than that of base and cooling demand, and especially the growth rate of heating demand in commercial sector is much higher. And we define the temperature-normalized demand conditioning that monthly temperatures are assumed as average monthly temperatures. The growth rate of heating demand in the estimated temperature-normalized demand is higher than that in the real demand. Our results are expected to be a base data for Winter Demand Management and short-term electricity demand forecasting.

Application of an Infrared Drying to Drying Process for Red Pepper (고추의 건조(乾燥) 공정(工程)에서 적외선(赤外線) 건조법(乾燥法)의 활용(活用)에 관한 연구(硏究))

  • Koh, H.K.;Cho, Y.J.;Kang, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.3
    • /
    • pp.230-243
    • /
    • 1990
  • This study was conducted to investigate the possibility of application of an infrared drying to drying process for red pepper. The performance of seramic heaters and the variation of temperature and moisture content of red pepper were analyzed during an infrared drying of red peppers. Also, the quality of dried red pepper was analyzed. The following results were obtained from this study. 1. The surface temperature of infrared heaters and the rising time required for steady state were mainly affected by electrical power consumed. 2. The heat energy required for heating red pepper was proposed to be calculated by the equation in terms of enthalpy of air and net heat flux by infrared heater in a drying chamber. The statistical model for net heat flux was developed. 3. The performance of the infrared heater used for heating red pepper was much affected by the distance of radiation, and the difference of temperatures appeared between the radiated surface and the inside of red pepper. 4. Electrical capacity of the infrared heater had a significant effect on the heating of red pepper. However, the effect of shape of heater on heating was not significant. 5. The variation of temperature of red pepper largely appeared in the range of 30 to 60% (db) in moisture content. The temperature of red pepper was almost constant at low moisture content. 6. The temperature of red pepper and heating time had significant effects on the quality for radiant heating. 7. When the electrical capacity of infrared heater and the distance of radiation are carefully designed in a dryer with the insulated drying chamber, infrared drying might be very effective in red pepper drying.

  • PDF

Optimization of Heating Conditions for Bacteria Associated with Food Hygiene (식품위생관련 세균에 대한 가열처리 조건의 최적화)

  • 이보순
    • The Korean Journal of Food And Nutrition
    • /
    • v.12 no.6
    • /
    • pp.569-574
    • /
    • 1999
  • Response surface methodology(RSM) was applied to determine the optimum heating conditions(tem-perature and time) for the inactivation of bacteria associated with food hygiene. Coefficients of determinations(R2) for the cell growth were 0.9155(P<0.05) in Pseudomonas aeruginosa 0.8997(P<0.05) in Escherichia coli 0.9690(P<0.01) in Salmonella typhimurium 0.9393(P<0.05) in Enterobacter aerogenes and 0.7905 in Vibrio parahaemolyticus. The growth of strains was significantly affected by the temperature and time and reaction to temperature was most closely correlated to the inhibition of growth. On the basis of superimposed contour maps of cell growth the optimum range of heating conditions were 55.62-6$0^{\circ}C$ and 19.25-30 min.

  • PDF