• 제목/요약/키워드: heating pipe line

검색결과 29건 처리시간 0.021초

가압기 밀림관 수평배관 외부 가열에 의한 열성층 유동 완화 수치해석 (Numerical analysis for mitigating thermal stratification flow of pressurizer surge horizontal pipe by outside heating)

  • 정일석;김유
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.670-678
    • /
    • 1997
  • A method to mitigate the thermal stratification phenomenon of pressurizer surge line is proposed by heating bottom outside of horizontal pipe. Unsteady two dimensional model has been used to numerically investigate an effect of heating the bottom of pipe. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature and streamline profiles of fluids and pipe walls with time are compared with the previous study result. The numerical result of this study shows that the outside heating can relaxate the thermal stratification flow of the pressurizer surge line. Maximum dimensionless temperature difference between hot and cold sections of the pipe inner wall which causes thermal stratification was reduced from 0.514 to 0.424 at dimensionless time 1, 632 and 1, 500 respectively.

전열밀폐식 X-L 파이프 보일러 난방장치의 특성 및 경제성 평가 (Evaluation on Characteristics and Economical Efficiency of X-L Pipe Boiler with Electric Heat Closed Type)

  • 김수만;전태규;양영준
    • 에너지공학
    • /
    • 제20권4호
    • /
    • pp.330-337
    • /
    • 2011
  • 난방장치로서 통상 가스 및 기름보일러가 많이 사용되어진다. 본 연구는 기존의 가스 및 기름 보일러에 의한 난방방식과 달리 밀폐된 X-L 파이프 내에 특수 제작된 전열선을 삽입하여 그 전열선에 전압을 인가함으로써 X-L 파이프 내 열매체의 온도를 상승시켜 난방하는 방법에 관한 것이다. 특수 제작된 전열선의 가닥수와 인가전압을 변화시켜 X-L 파이프 보일러의 특성과 발열 메카니즘을 파악하였다. 또한 X-L 파이프 보일러와 가스 및 기름보일러와의 난방비용을 객관적인 자료에 근거하여 서로 비교를 함으로써 그 경제성을 평가하였다. 그 결과 X-L 파이프 보일러는 기름(보일러등유)보일러의 28%, 가스(천연가스)보일러의 58%의 비용으로 난방이 가능함을 확인하였다.

지역난방배관의 누수감지 신뢰성 향상에 관한 연구 (A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System)

  • 신춘식;안영주;변기식
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.66-72
    • /
    • 1999
  • Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe. the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.

  • PDF

지역난방 열수송관 국부 부식 파손 분석 (Failure Analysis on Localized Corrosion of Heat Transport Pipe in District Heating System)

  • 김유섭;채호병;김우철;정준철;김희산;김정구;이수열
    • Corrosion Science and Technology
    • /
    • 제19권3호
    • /
    • pp.122-130
    • /
    • 2020
  • In this study, a corrosion failure analysis of a heat transport pipe was conducted, as the result of a pinhole leak. Interestingly, the corrosion damage occurred externally in the pipeline, resulting in severe thickness reduction near the seam line. Also, while a stable magnetite protective film formed on the inner surface, the manganese oxide formation occurred only on the outer surface. The interior and exterior of the pipe were composed of ferrite and pearlite. The large manganese sulfide and alumina inclusions were found near the seam line. In addition, the manganese sulfide inclusions resulted in grooving corrosion, which progressed in the seam line leading to the reduction in the thickness, followed by the exposure of the alumina in the matrix to the outer surface. To note, the corrosion was accelerated by pits generated from the boundaries separating the inclusions from the matrix, which resulted in pinhole leaks and water loss.

온실 난방시스템 설계를 위한 온수난방배관의 방열량 분석 (Analysis of Heat Emission from Hot Water Pipe for Greenhouse Heating System Design)

  • 신현호;남상운
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.204-211
    • /
    • 2019
  • 본 연구는 국내 온실의 환경설계 기준 설정에 필요한 기초자료 제공을 목적으로 온수난방 방식을 채택하고 있는 상업용 온실 2곳에서 난방 중 열환경 계측 실험을 실시하고, 온수난방 배관의 열전달 특성을 분석하여 난방배관의 단위길이 당 방열량 자료를 제시하였다. 실험 기간동안 두 온실의 평균기온은 각각 $16.3^{\circ}C$$14.6^{\circ}C$로 조절되었으며, 난방배관의 온수 온도는 평균 $52.3^{\circ}C$$45.0^{\circ}C$로 관측되었다. 실험결과 난방배관 표면의 자연대류열전달계수는 $5.71{\sim}7.49W/m^2^{\circ}C$의 범위로 분석되었다. 난방배관 내의 유속이 0.5m/s 이상일 때에는 관내의 수온과 관 외부의 표면온도 차이가 크지 않은 것으로 나타났다. 이를 바탕으로 난방배관의 관류열전달계수를 수평원통에서의 층류 자연대류열전달계수의 형태로 유도하였다. 유도된 관류열전달계수 식을 변형하여 관의 규격과 온수-실내공기의 온도차를 입력 변수로 하는 난방배관의 단위길이 당 방열량 산정식을 개발하였다. 본 연구 결과를 기존에 제공되고 있는 국내외 여러 자료와 비교한 결과 JGHA 자료와 가장 유사한 것으로 나타났다. 국내 온실의 설계에서 적용하고 있는 NAAS 자료와 국외의 BALLS 및 ASHRAE 자료는 값이 너무 큰 것으로 판단된다. 따라서 국내 온실의 환경설계기준을 제정하고, 고시하기 위해서는 추가적인 실험을 통해 이 부분에 대한 충분한 검토가 필요할 것으로 판단된다.

지역난방 에너지 공동주택의 다중 열공급 제어 알고리즘 개발에 관한 해석적 연구 (Study on the Development of Multi Heat Supply Control Algorithm in Apartment Building of District Heating Energy)

  • 변재기;최영돈;박명호;신종근
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.63-70
    • /
    • 2011
  • In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.

NUMERICAL ANALYSIS FOR UNSTEADY THERMAL STRATIFIED FLOW WITH HEAT TRACING IN A HORIZONTAL CIRCULAR CYLINDER

  • Jeong, Ill-Seok;Song, Woo-Young;Park, Man-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.304-309
    • /
    • 1997
  • A method to mitigate the thermal stratification flow of a horizontal pipe line is proposed by heating external bottom of the pipe with electrical heat tracing. Unsteady two dimensional model has been used to numerically investigate an effect of the external Denting to the thermally stratified flow. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature distribution, streamline profile and Nusselt numbers of fluids and pipe walls with time are analyzed in case of externally heating condition. no numerical result of this study shows that the maximum dimensionless temperature difference between the hot and the cold sections of pipe inner wall is 0.424 at dimensionless time 1,500 ann the thermal stratification phenomena is disappeared at about dimensionless time 9,000. This result means that external heat tracing can mitigate the thermal stratification phenomena by lessening $\Delta$ $T_{ma}$ about 0.1 and shortening the dimensionless time about 132 in comparison with no external heat tracing.rnal heat tracing.

  • PDF

외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구 (Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature)

  • 변재기;이규호;최영돈;신종근
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

소결금속 윅과 메탄올을 사용하며 바이패스라인이 부착된 루프히트파이프의 작동 특성 (Operating Characteristics of a Sintered-Metal Wick/Methanol Loop Heat Pipe Having a Bypass Line)

  • 부준홍;정의국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2130-2135
    • /
    • 2007
  • Operating characteristics of a loop heat pipe (LHP) having a bypass line was investigated experimentally. The LHP had a sintered metal wick as a capillary structure and methanol as a working fluid. The sintered metal wick was made of stainless steel of which the average pore size was 5 ${\mu}m$and porosity of 47%. A bypass line of a small diameter was attached between the vapor escape passage and the liquid reservoir. The dimension of the flat evaporator was $50(L){\times}40(W){\times}30(H)$ mm and that of the condenser was $50(L){\times}40(W){\times}11(H)$ mm. Wall and pipe material of the LHP was stainless steel and heating area was 35(W) mm${\times}$35(L) mm. The inner diameters of vapor and liquid transport lines were 4.0 mm and 2.0 mm, and the lengths of the two lines were both 0.5 m. The LHP was tested for three different tilt angles of horizontal, favorite tilt, and adverse tilt. The thermal load range was up to 290 W at the condenser above evaporation position. Furthermore, the effect of a bypass line on the start-up transient as well as steady-state operation was presented and discussed.

  • PDF

Heat Tracing이 있는 수평배관 내부 열성층 유동의 비정상 2차원 열전달 해석 (An Analysis of Unsteady 2-D Heat Transfer of the Thermal Stratification Flow inside Horizontal Pipe with Electrical Heat Tracing)

  • 정일석;송우영
    • 에너지공학
    • /
    • 제6권2호
    • /
    • pp.119-128
    • /
    • 1997
  • 수평배관의 열성층 유동을 완화하기 위하여 아래부분에 Heat Tracing을 한 수평배관의 외부 가열에 의한 열성층 유동과 열전달 특성을 수치적으로 해석하기 위하여 비정상 2차원 모델을 이용하였다. 무차원 지배방정식은 제어체적방법과 SIMPLE 알고리즘을 사용하여 해를 구하였다. Heat Tracing이 있는 수평배관 내부 열성층 유동의 등온선, 유선분포, Nusselt수, 온도 분포를 해석하였다. 무차원 시간 1,500에서 최대 무차원 온도차가 0.424로 계산되어졌고 무차원 시간 9,000 이후에는 열성층 현상이 없어졌다.

  • PDF