DOI QR코드

DOI QR Code

Numerical analysis for mitigating thermal stratification flow of pressurizer surge horizontal pipe by outside heating

가압기 밀림관 수평배관 외부 가열에 의한 열성층 유동 완화 수치해석

  • Published : 1997.05.01

Abstract

A method to mitigate the thermal stratification phenomenon of pressurizer surge line is proposed by heating bottom outside of horizontal pipe. Unsteady two dimensional model has been used to numerically investigate an effect of heating the bottom of pipe. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature and streamline profiles of fluids and pipe walls with time are compared with the previous study result. The numerical result of this study shows that the outside heating can relaxate the thermal stratification flow of the pressurizer surge line. Maximum dimensionless temperature difference between hot and cold sections of the pipe inner wall which causes thermal stratification was reduced from 0.514 to 0.424 at dimensionless time 1, 632 and 1, 500 respectively.

Keywords