• 제목/요약/키워드: heating fuel

검색결과 765건 처리시간 0.047초

A Study on Indoor and Personal Exposures Concentrations to Carbon Monoxide in the Asan Area

  • Son, Bu-Soon
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.1-3
    • /
    • 2000
  • Indoor carbon monoxide (CO) concentration and personal CO exposures were measured Asan where CO poisoning from twenty coal usage briquette as a domestic fuel to cook and space heating. Twenty-five were houses selected from the Asan area for the survey conducted in February 1997. Newly developed passive CO samplers were placed in the kitchen and living room for the indoor concentration measurement and were worn by homemakers for personal exposure monitoring. The daily average of indoor CO concentration was 16ppm in the kitchen and 10ppm in the living room. The indoor concentration and personal exposures to CO were different in types of the space heating system. House ventilating methods and socioeconomic conditions were also important factors in determining the indoor and personal CO level in Asan.

  • PDF

열병합시스템 경제성 평가 프로그램의 개발 및 적용에 관한 연구 (Development and Application of an Economic Assessment Program of Cogeneration Systems)

  • 박차식;김용찬
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1547-1554
    • /
    • 1998
  • The object of this study was to develop an economic assessment program for the optimal design of the cogeneration systems composed of combining engine, generator, waste heat recovery exchanger, absorption chiller, and boiler, etc. The energy demand categorized by electric power, heating, cooling and water supply was determined by statistical data of the existing cogeneration systems. An economic assessment was performed by comparing the total cost of cogeneration system with that of non-cogeneration system. The total cost was evaluated by adding initial investment to operational cost considering efficiency of equipment, cost of equipment, fuel and electricity. To confirm the validity of the developed program, a hotel building with an area of $127,960m^2$ was selected, and the simulated results were compared with the measured data. The difference between the simulated and the measured values for the selected hotel building was approximately 12% for annual electric consumption.

구술로 본 1970년대 이후 전주지역 단독주택 부엌의 변화 (The change of Kitchen in a Single Detached House in Jeonju City after 70's through Oral Life History method)

  • 박선희
    • 한국주거학회논문집
    • /
    • 제17권6호
    • /
    • pp.55-63
    • /
    • 2006
  • The purpose of this study is to investigate the change of kitchen in a single detached house in Jeonju city after 70's. Oral life history method which has 12 women's personal narratives and 17 women's personal narratives with written reports was used as a research method of this study. The results of the study were obtained as follows: 1) It was beginning about late 1970 year that heating system and cooking place were separated in a house. 2) Many kitchens were reconstructed for indoor stand-up work place from late 1970's to the early 1980's. 3) There were major factors such as heating system, cooking fuel, and work center in the change of kitchen in old houses. 4) The kitchen toward the center with a living room was appeared in the floor plan of modem house after 1990's. The symbolic words of the indoor kitchen that work for women were 'warmness' and 'convenience'.

제로 에너지 하우스 구축을 통한 설계, 시공, 유지관리 최적 방안에 관한 연구 및 제안 (The Study Of Optimum Method About The Architecture, Construction, And Maintenance Through The Construction Of Zero Energy House)

  • 김선근;권순욱
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.42-50
    • /
    • 2014
  • In the thesis, the case of zero energy house construction applied with various Active factors and Passive factors which is the real residence as a standard not a normal experimental residence was evaluated, analyzed, and organized. The thesis can be the base data to construct another similar case of zero energy house.

2500kW 유도용해용 직렬공진형 인버터 개발 (Development of 2500kW Series Resonant Inverter for Induction Smelting)

  • 유효열;심은용;정대환;강재봉;강호현;김왕래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.366-369
    • /
    • 2005
  • The smelting system using induction heating technology has many advantages over conventional fossil fuel regarding energy efficiency, environmental aspect and so on. This paper introduces the principal and technical trends of Induction heating technology, and describes recently developed 2500kW induction smelting inverter, The developed inverter is a series resonant type using high speed Thyristor (SCR) and employs state-of-art digital controller using DSP.

  • PDF

기축건물의 제로에너지 하우스 하자 사례를 통한 공종별 문제점 및 최적구축 방안에 관한 연구 (The Study on Activity Star Problem and Optimum Construction Method Through the Defect Case of Zero Energy House in the Existing Building)

  • 김선근;권순욱
    • 한국전기전자재료학회논문지
    • /
    • 제28권4호
    • /
    • pp.262-270
    • /
    • 2015
  • In this paper existing buildings, not a new buildings and house for living people not just a displaying and a viewing, created by the imagine effect or virtual simulation was applied various Active and Passive elements. After constructing zero-energy houses, through default case happened during operation period it is described problems and solutions about field part, work classification, installation by Location part, and Installation equipment part. Since then, to take advantage of this thesis, it's the purpose of this paper using as the baseline data for building a zero-energy house in another similar case.

차량용 연소식 난방기의 열 및 유동특성에 대한 수치연구 (Numerical Investigation on the Thermal and Flow Characteristics of Combustion Heater for Commercial Vehicle)

  • 황창환;백승욱
    • 한국연소학회지
    • /
    • 제16권2호
    • /
    • pp.40-46
    • /
    • 2011
  • The diesel pre-heater has being used in cabin heating and coolant heating of engine to reduce the engine warm up time for commercial vehicle. The pre-heaters are classified as diesel spray combustor and it forms diffusion flame. By using swirler, a recirculation flow of hot product gases is established near the fuel nozzle and it helps the maintaining of diffusion flame. The design difference of swirler can affect on reaction characteristics and temperature distribution inside pre-heater. The purpose of this study is the investigation of the effect of swirler configuration on combustion characteristics. To solve spray combustion problem, the Euler-Lagrange approach discrete model is used to track droplet trajectory and evaporation history. The PDF equilibrium model is used for chemical reaction model. These models are implemented into the FLUENT code.

심야전기보일러 대체 Heat Pump의 경제성 분석 (Analysis on Economic Feasibility of Electric Night Storage Heat Pump as a Substitution of a Heater)

  • 정훈;조종영;이철희
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.119-124
    • /
    • 2011
  • Electric night storage heater was introduced and disseminated for power grid balancing and efficient management of power generation facility. But fuel cost for heating has been increased rapidly while the cost of electricity increased slightly. This abnormal rate system caused peak load in winter at last. To solve this problem, application of an air source heat pump was suggested. In the study, the effect of replacing night heater by heat pump and the economics were analysed. In addition the expectation of prospect of heat pump penetration was simulated based on surveyed and investigated data. As a result, fund supporting as well as institutional backing was needed for effective propagation and return of investment.

Drained End Shield Effects on Heat Deposition Rate Distribution in CANDU 6 Reactor End Shield Structure

  • Jin, Yung-Kwon;Kim, Kyo-Youn;Hwang, Hae-Ryong
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.570-577
    • /
    • 1994
  • The loss of water in the carbon steel balls and water region of the end shield for CANDU 6 reactor could lead to significant temperature gradient through the end shield structure which amy result in the excessive deformation. With an assumed end shield drained scenario, the heat deposition rates were calculated through the end shield associated with the central fuel channel during full power operation as an initial step to thermal stress analysis. The drained case was compared with that of water present normal case in therms of heat deposition rater and the total heating throughout the end shield regions. The compared results show that the heat deposition and the total heating remain almost the same between the two cases. It was found that the change of volume integrated flux in the end shield regions due to the loss of water contribute a negligible effect on the heat deposition in this region.

  • PDF

중국 연변 조선족 전통농가의 시설설비 실태조사 (A Field Study on the Facilities and Equipments of the Traditional Farmhouse in Lungching, China)

  • 고도임
    • 대한가정학회지
    • /
    • 제36권6호
    • /
    • pp.123-132
    • /
    • 1998
  • This paper is a part of "The Study of the Traditionla Korean Ethnic Farmhousing in Yanbian, China" The purpose of this study is to investigate the facilities and equipments of the traditional farmhouse in the villages of Lungching China. The data is collected from 124 households in the villages based on the survey conducted using questionnaire and photograph. The major findings are: 1) The people in farmhouse use wood as a fuel for cooking and the method of cooking is traditional style using their iron pots. 2) Heating system of the house is ondol type of heating using. wood which is also traditional type. This means that the floor heating of the house and cooking food can be carried out simultaneously. 3) Even though pump system and running water system are the two kinds of water supply that are available in the villages, majority of people use pump system. Many houses have no drainage facilities but few houses have got bad drainage system. 4) From the planning stage of the farm house facilities and equipments for ventilation is not considered and hence it is not provided in most of the houses. 5) Farmhouses are oriented to the south and the windows and the doors are covered either with viny1 or cloth during winter time effecting the lighting system of the house. 6)Many of the houses use incandescent lights. But the switchs and the electric Outlets are short in number. 7) Sanitation facilities are worst equipped compared to other facilities present in Lungching villages of China. of China.

  • PDF