• Title/Summary/Keyword: heat variations

Search Result 672, Processing Time 0.027 seconds

Roles of Wind Stress Variations in the Western North Pacific on the Decadal Change of ENSO (ENSO 십년 변동에 미치는 북서태평양 지역에서의 바람 응력 변동의 역할)

  • Lee, Yoon-Kyoung;Moon, Byung-Kwon;Kwon, Min-Ho;Jhun, Jong-Ghap
    • Journal of the Korean earth science society
    • /
    • v.27 no.6
    • /
    • pp.687-694
    • /
    • 2006
  • This paper investigated the effects of wind stress forcing in the western North Pacific on ENSO decadal change before and after the late 1970s. The SVD analysis of SODA data shows that a positive wind stress curl is dominant in the western North Pacific at the ENSO mature phase, which leads to the ENSO phase change by discharge/recharge heat contents in the equatorial Pacific. Before the late 1970s, the wind stress curl in the western North Pacific was strong. This strong wind forcing that is associated with the fast discharge of heat contents in the equator led to the short period and the weak intensity of ENSO occurred during the 1960-1970. On the other hand, after the late 1970s the relatively weak wind stress curl was accompanied with the long period and the strong intensity of ENSO. The simple coupled model experiments also confirm that the amplitude and dominant period of ENSO decrease when the wind stress curl in the western North Pacific projects more strongly into the ocean at the TNSO mature phase. Our results support that the changes in the behavior of ENSO after the late 1970s are associated with the wind stress variation in the western North Pacific.

A study on grid aspect ratio of fire dynamics simulator (FDS의 격자 종횡비에 관한 연구)

  • Kim, Won Ouk;Park, Woe-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.923-928
    • /
    • 2015
  • The FDS is one of the most used programs for fire analysis and needs an optimal grid selection for an accurate analysis. This study selected various grid aspect ratios (ARs) for selection of optimal grid and analyzed them with FDS v 6.1.2. A calculation time of 10 min. was used, which is enough to obtain the time average value of temperature changes. Temperature, visibility, and the time average value of mass balance are obtained from 200-600 s, which is a period of maintaining quasi-steady state. Two polyurethane fires of 1 [MW] and 2 [MW] in two enclosures of $10{\times}10{\times}3[m^3]$ and $20{\times}20{\times}3[m^3]$ were considered. Time variations of heat release rates, temperature, visibility, and mass balance were compared for ARs from 1-6. The heat release rates were accurate for all aspect ratios regardless of fire and enclosure sizes. The quasi-steady state temperature and visibility were well predicted for $AR{\leq}5$. Temperature drop and skewness of mass conservation, however, increased with increasing aspect ratio. Therefore, careful investigation of the grid size is recommended in performance-based design when $AR{\geq}3$, where temperature and visibility in early stage of a fire are important parameters. For accurate simulations of enclosure fires, grid sizes of 0.1~0.2 [m] and smaller in the vertical direction and $AR{\leq}2$ are recommended.

Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts (볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석)

  • Yeon, Yeong-Mo;Kim, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.67-75
    • /
    • 2020
  • In this study, the risk of heat generation due to normal and overload currents that vary with the abnormal loosening angle of wire-connecting bolts were identified. The risks were analyzed based on the thermal characteristics to minimize the carbonization accidents of terminal blocks inside distribution panels typically used in industrial sites. We applied a method for measuring the heating temperature and temperature variations in the terminal blocks in real-time by installing a resistance temperature detector sensor board in the terminal block. The experimental results showed that the terminal block model with a low-rated current exhibited a higher heating temperature, thus, confirming the need to select the terminal block capacity based on load currents. Additionally, the higher the rated current of the terminal block with a high-rated current and the higher the degree of loosening, the faster the carbonization point. Such heating temperature monitoring enabled real-time thermal temperature measurement and a step-by-step risk level setting through thermal analysis. The results of the measurement and analysis of carbonization risks can provide a theoretical basis for further research regarding the risk of fire due to carbonization. Furthermore, the deterioration measurement method using the temperature sensor board developed in this study is widely applicable to prevent fires caused by poor electrical contact as well as risk-level management.

Determination of Design Basis for a Storage System for Spent Fuel in Korea (국내 사용후핵연료 저장시스템의 설계기준 설정 인자 고찰)

  • Yoon, Jeong-Hyoun;Lee, Eun-Yong;Woo, Sang-In;Kim, Tae-Man
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • Safe operation and maintenance of engineered dry storage systems for spent fuel from nuclear power plants basically depends on adequately adopted design requirements. The most important design target of the system are those which provide the necessary assurances that spent fuel can be received, handled, stored and retrieved without undue risk to health and safety of workers and the public. To achieve these objectives, the design of the system incorporates features to remove spent fuel residual heat, to provide for radiation protection, and to maintain containment over the lifespan of the system as specified in the design specifications. The features also provide for all possible anticipated operational occurrences and design basis events in accordance with the design basis as guided by the designated regulations. The general performance requirements of a projected storage system are introduced in this paper. The storage system is designed to store fuel assemblies in associated with designated regulatory requirements. Small increases/decreases in maximum burnup can be adjusted with cooling time. These variations are compensated for by a corresponding small site-specific increase/decrease in the design basis-cooling period, as long as the maximum heat load and radioactivity of loaded fuel assemblies are met. Generic design basis events considered for the storage system are summarized. Shielding and radiological requirements along with mechanical and structural are derived in this study.

Effect of different short-term high ambient temperature on chicken meat quality and ultra-structure

  • Zhang, Minghao;Zhu, Lixian;Zhang, Yimin;Mao, Yanwei;Zhang, Mingyue;Dong, Pengcheng;Niu, Lebao;Luo, Xin;Liang, Rongrong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.5
    • /
    • pp.701-710
    • /
    • 2019
  • Objective: This study investigated the effect of different acute heat stress (HS) levels on chicken meat quality and ultra-structure. Methods: Chickens were randomly divided into 7 groups to receive different HS treatments: i) $36^{\circ}C$ for 1 h, ii) $36^{\circ}C$ for 2 h, iii) $38^{\circ}C$ for 1 h, iv) $38^{\circ}C$ for 2 h, v) $40^{\circ}C$ for 1 h, vi) $40^{\circ}C$ for 2 h, and vii) un-stressed control group ($25^{\circ}C$). Blood cortisol level, breasts initial temperature, color, pH, water holding capacity (WHC), protein solubility and ultra-structure were analyzed. Results: HS temperatures had significant effects on breast meat temperature, lightness ($L^*$), redness ($a^*$), cooking loss and protein solubility (p<0.05). The HS at $36^{\circ}C$ increased $L^*{_{24h}}$ value (p<0.01) and increased the cooking loss (p<0.05), but decreased $a^*{_{24h}}$ value (p<0.05). However, as the temperature increased to $38^{\circ}C$ and $40^{\circ}C$, all the values of $L^*{_{24h}}$, cooking loss and protein denaturation level decreased, and the differences disappeared compared to control group (p>0.05). Only the ultimate $pH_{24h}$ at $40^{\circ}C$ decreased compared to the control group (p<0.01). The pH in $36^{\circ}C$ group declined greater than other heat-stressed group in the first hour postmortem, which contributed breast muscle protein degeneration combining with high body temperature, and these variations reflected on poor meat quality parameters. The muscle fiber integrity level in group $40^{\circ}C$ was much better than those in $36^{\circ}C$ with the denatured position mainly focused on the interval of muscle fibers which probably contributes WHC and light reflection. Conclusion: HS at higher temperature (above $38^{\circ}C$) before slaughter did not always lead to more pale and lower WHC breast meat. Breast meat quality parameters had a regression trend as HS temperature raised from $36^{\circ}C$. The interval of muscle fibers at 24 h postmortem and greater pH decline rate with high body temperature in early postmortem period could be a reasonable explanation for the variation of meat quality parameters.

Factors Affecting Process Temperature and Biogas Production in Small-scale Rural Biogas Digesters in Winter in Northern Vietnam

  • Pham, C.H.;Vu, C.C.;Sommer, S.G.;Bruun, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.7
    • /
    • pp.1050-1056
    • /
    • 2014
  • This study investigated the main factors influencing digester temperature and methods to reduce heat losses during the cold season in the subtropics. Four composite digesters (two insulated and two uninsulated) were buried underground to measure their internal temperature ($^{\circ}C$) at a depth of 140 cm and 180 cm, biogas production and methane ($CH_4$) concentration in biogas from August to February. In parallel the temperature of the air (100 cm above ground), in the slurry mixing tank and in the soil (10, 100, 140, and 180 cm depth) was measured by thermocouple. The influent amount was measured daily and the influent chemical composition was measured monthly during the whole experimental period. Seasonal variations in air temperature significantly affected the temperature in the soil, mixing tank and digester. Consequently, biogas production, which is temperature dependent, was influenced by the season. The main factors determining the internal temperature in the digesters were insulation with Styrofoam, air temperature and temperature of slurry in the mixing tank. Biogas production is low due to the cold climate conditions in winter in Northern Vietnam, but the study proved that storing slurry in the mixing tank until its temperature peak at around 14:00 h will increase the temperature in the digester and thus increase potential biogas production. Algorithms are provided linking digester temperature to the temperature of slurry in the mixing tank.

Interaction Between Transparent Dielectric of Bi2O3-B2O3-BaO-ZnO Glass and Ag Electrode (Bi2O3-B2O3-BaO-ZnO계 투명유전체와 Ag 전극의 반응)

  • An, Yong-Tae;Choi, Byung-Hyun;Kim, Hyung-Sun
    • Korean Journal of Materials Research
    • /
    • v.18 no.12
    • /
    • pp.678-682
    • /
    • 2008
  • This study investigates $Bi_2O_3$-$B_2O_3$-BaO-ZnO glass with variations of the $Co_3O_4$ content (0.25, 0.5, 1, and 2 wt%) and the interaction between transparent dielectric and Ag electrodes heat-treated at $500-560^{\circ}C$ for 30 min. The glass transition temperature, softening temperature and thermal expansion coefficient were $432^{\circ}C$, $460^{\circ}C$ and $81.4{\times}10^{-7}/^{\circ}C$, respectively. The transmittance of 0.25 wt% $Co_3O_4$ to which dielectric was added was highest and was decreased due to coloration with the addition of more than 0.25 wt%. However, without $Co_3O_4$, the transmittance of the transparent layer was decreased due to the formation of $Ba_5Bi_3$; however, the occurrence of the crystal phase decreased as a result of the addition of $Co_3O_4$. The amount of $Co^{2+}$ ions increased as the $Co_3O_4$ increased. With a maximum of $Co^{3+}$ ions, the highest transmittance was observed.

Study on the Retreatment Techniques for NOAA Sea Surface Temperature Imagery (NOAA 수온영상 재처리 기법에 관한 연구)

  • Kim, Sang-Woo;Kang, Yong-Q.;Ahn, Ji-Sook
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.4
    • /
    • pp.331-337
    • /
    • 2011
  • We described for the production of cloud-free satellite sea surface temperature(SST) data around Northeast Asian using NOAA AVHRR(Advanced Very High Resolution Radiometer) SST data during 1990-2005. As a result of Markov model, it was found that the value of Markov coefficient in the strong current region such as Kuroshio region showed smaller than that in the weak current. The variations of average SST and regional difference of seasonal day-to-day SST in spring and fall were larger than those in summer and winter. In particular, the distribution of the regional difference appeared large in the vicinity of continental in spring and fall. The difference of seasonal day-to-day SST was also small in Kuroshio region and southern part of East Sea due to the heat advection by warm currents.

A Flame Transfer Function with Nonlinear Phase (비선형 위상을 가지는 화염전달함수)

  • Yoon, Myung-Gon;Kim, Jina;Kim, Deasik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.78-86
    • /
    • 2016
  • In this paper we propose a new frame transfer function model describing the variations of a heat release rate in response to an external flow oscillation in gas turbine systems. A critical difference of our model compared to the so-called $n-{\tau}$ model which has been widely used for a prediction of combustion instability (CI), is that our model is able to describe a nonlinear relation between phase and frequency. In contrast, the phase part of the $n-{\tau}$ model is a pure time delay and thus the phase should be a linear function of frequency, which is inconsistent with many experimental results of real combustion systems. For an illustration, our new model is applied to experimental data and the effect of phase nonlinearity is investigated in the context of combustion instability.

Adsorption Characteristics of Water Vapor on Zeolite (Zeolite의 수증기 흡착특성)

  • Lee, Song-Woo;Na, Young-Soo;An, Chang-Doeuk;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.667-672
    • /
    • 2011
  • The purpose of this work is to present the experiment results by a dynamic adsorption of water vapor on pelletized zeolites (ADZ300, ADZ400, and ADZ500) in fixed bed. The breakthrough curves of water vapor with several different concentrations and temperature in the range of 25~45 $^{\circ}C$ on zeolite bed were investigated. In the same conditions, the breakthrough time on ADZ400 and ADZ500 were little longer than ADZ300, and the equilibrium adsorption capacity on ADZ500 was highest. The higher the concentration of water vapor was, the faster the breakthrough time was, and the slope of breakthrough curves showed a tendency to increase. The faster the flow rate of water vapor was, the faster the breakthrough time was relatively, but variations between flow rate and breakthrough time did not have a proportional relationship. The breakthrough curve maintained constant gradient in spite of variation of flow rate in the same concentration. The temperature rise in zeolite bed by adsorption heat was occurred in the early stage of adsorption. After water molecule layers were formed on the surface of zeolite, the temperature was slowly cooled by water vapors continuously flowed in as constant temperature. The greater the concentration of water vapor and adsorption temperature were, the temperature difference in zeolite bed was increased.