• Title/Summary/Keyword: heat transfer capacity

Search Result 391, Processing Time 0.024 seconds

The Effect of Non-uniform Superheat on the Performance of a Multi-path Evaporator (다중 유로에서 과열도의 불균형에 따른 증발기의 성능 특성에 관한 연구)

  • 최종민;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1043-1048
    • /
    • 2003
  • An experimental investigation was executed to determine the capacity degradation due to non-uniform refrigerant distribution in a multi-path evaporator. In addition, the possibility of recovering the capacity reduction by controlling the refrigerant distribution among refrigerant paths was assessed. The finned-tube evaporator, which had a three-path and three-depth-row, was tested by controlling inlet quality, exit pressure, and exit superheat for each refrigerant path. The capacity reduction due to superheat unbalance between each path was as much as 30%, even when the overall evaporator superheat was kept at a target value of 5.6$^{\circ}C$. It may indicate that the internal heat transfer within the evaporator assembly caused the partial capacity drop. For the evaporator having air mal-distributions, the maximum capacity reduction was found to be 8.7%. A 4.5% capacity recovery was obtained by controlling refrigerant distribution to obtain the target superheat at the outlet of each path.

The evaluative study of window defrost using Computational Fluid Dynamics (CFD를 이용한 Window Defrosting 평가)

  • Lee, I.S.;Im, H.N;Choi, J.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.179-182
    • /
    • 2011
  • The purpose of this study is to evaluate a defrost model for the possibility of defrosting on wheelhouse window and the heat capacity if defrosting nozzle by using the commercial CFD solver FLUENT. A detailed simulation model has been created which contains the defrosting nozzle, window and the interior/exterior forced convection boundary. In this numerical study, the heat and mass transfer coupled during defrosting and investigated the defrost time for different hot gas temperature, external wind speed and temperature condition.

  • PDF

Heat Transfer Equation and Finite Element Analysis Considering Frozen Ground Condition the Cyclic Loading (지반의 동결조건을 고려한 열전도 구성방정식과 유한요소해석)

  • Kim, Young-Seok;Kang, Jae-Mo;Hong, Seung-Seo;Kim, Kwang-Jin
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.3
    • /
    • pp.39-45
    • /
    • 2010
  • When the ground temperature drops below $0^{\circ}C$, wet soils expand due to the ice formation in their porous space. This results in frost heave which causes structural stability problems. Frost heave is attributed by several factors such as physical soil properties and heat transfer including pore water phase change. Due to the complex physical phenomena, reliable and verified multi-dimensional numerical models for frost heave problems are still in a research stage. This study presents an efficient and simple method of overcoming numerical problems associated with sudden jump of heat capacity due to the phase change from water to ice in the pore space. This paper proposes heat transfer equation and finite element method when the saturated soils or porous rocks are subjected to freezing. Numerical analyses using the proposed method agree well with the known closed form solution and the laboratory test results.

  • PDF

Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis (열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교)

  • Hwang, Se-Yun;Lee, Jang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • This study discusses the thermal insulation capacity of variant of NO96 LNG (liquefied natural gas) cargo containment insulation system. Changing the insulation materials and the insulation layers of conventional GTT NO96 containment system, The thermal resistance and BOR(boil off rate) caused by the heat transfer between cryogenic and environmental temperature is discussed. Therefore, thermal analysis of LNG CCS(cargo containment system) is carried out to determine the insulation capabilities. Also, BOR is evaluated in terms of the total amount of heat invaded into CCS(cargo containment system). Variant of NO96 CCS such as NO96, NO96GW and NO96L3 membrane type during laden voyage is selected for the comparative study. Finite element model for heat transfer analysis is conducted by employing the equivalent thermal resistance model to simplify the complex insulation layers. Finally the results for each variant model are relatively compared and discussed to minimize the BOR.

Heat transfer of green timber wall panels (그린팀버월 패널의 열전달 특성)

  • Kim, Yun-Hui;Jang, Sang-Sik;Shin, Il-Joong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

Numerical Simulation of the Aluminum Alloys Solidification in Complex Geometries

  • Monteiro Eliseu;Rouboa Abel
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1773-1780
    • /
    • 2005
  • The process of mould design in the foundry industry has been based on the intuition and experience of foundry engineers and designers. To bring the industry to a more scientific basis the design process should be integrated with scientific analysis such as heat transfer. The production by foundry techniques is influenced by the geometry configuration, which affects the solidification conditions and subsequent cooling. Numerical simulation and/or experiments make possible the selection of adequate materials, reducing cycle times and minimizing production costs. The main propose of this work is to study the heat transfer phenomena in the mould considering the phase change of the cast-part. Due to complex geometry of the mould, a block unstructured grid and a generalized curvilinear formulation engaged with the finite volume method is described and applied. Two types of boundary conditions, diffusive and Newtonian, are used and compared. The developed numerical code is tested in real case and the main results are compared with experimental data. The results showed that the solidification time is about 6 seconds for diffusive boundary conditions and 14.8 seconds for Newtonian boundary conditions. The use of the block unstructured grid in combination with a generalized curvilinear formulation works well with the finite volume method and allows the development of more efficient algorithms with better capacity to describe the part contours through a lesser number of elements.

Characteristics of Closed Circuit Cooling Tower with Variation of Tube Diameter (멀티패스 밀폐식 냉각탑의 관경변화 특성)

  • Shim, Gyu-Jin;Lee, Ho-Saeng;Kim, Eun-Pil;Yoon, Jung-In;Kwon, O-Ick
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.531-536
    • /
    • 2008
  • This paper presents experimental result of characteristics about Closed circuit Cooling Tower having a rated 2RT. The experimental apparatus has been set-up with a conventional type system. The test section is heat exchangers of cooling tower that consist of different vertical tubes, 15.88mm with 10 rows and columns and 19.05 mm with 8 rows and 12 columns. The main results were summarized as follows : The values of heat and mass transfer coefficients of cooling tower operating with two paths are higher than these with one path. Cooling capacity per unit volume using 15.88mm tubes are higher than 19.05mm tubes.

  • PDF

An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube (베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구)

  • Jun, Chul-Ho;Lee, Ho-Saeng;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat: Part II - Shaft Misalignment Effect (변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 II-축 경사도 영향)

  • Chun, Sang-Myung;Jang, Si-Youl
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.305-310
    • /
    • 2001
  • Within some degree of journal misalignment, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined under the condition of variable density and specific heat. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the effects of variable density and specific heat on shaft misalignment are significant in determining the load capacity of a journal bearing operating at high speed.

  • PDF

Experimental Study of Heat Transfer Performance of Variable Conductance Heat Pipe with Screen Mesh Wick (Mesh Wick형 가변전열 히트파이프의 열전달 성능에 관한 실험적 연구)

  • Park, Y.S.;Byon, G.S.;Suh, J.S.;Park, K.H.;Lee, K.W.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.7-12
    • /
    • 2003
  • heat pipe with screen meshed wick. The heat pipe was designed in 200 screen meshs, 500 mm length and 12mm O.D tube of copper, water as working fluid and nitrogen as non-condensible gas. Heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Experimental data of wall temperature distribution along axial length is presented for heat transport capacity, condensor cooling water temperature change, degrees of an inclination angle, and operating temperature.

  • PDF