• Title/Summary/Keyword: heat protection

Search Result 586, Processing Time 0.035 seconds

Improving the Corrosion Resistance of Cold-Rolled Carbon Steel by Treatment with a Hybrid Organic/Inorganic Coating Solution (유/무기 하이브리드 코팅액에 의한 냉간압연강판의 내식특성)

  • Kim, Jung-Ryang;Choi, Chang-Min;Nam, Ki-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.405-412
    • /
    • 2012
  • In the past, a very popular way to reduce the corrosion rate of zinc was the use of chemical conversion layers based on $Cr^{+6}$. However, the use of chromium salts is now restricted because of environmental protection legislation. Previous research investigated the optimum corrosion resistance of galvanized steel treated with an organic/inorganic solution containing Si. The result showed that the optimum corrosion resistance occurred by heat treatment of $190^{\circ}C$ in 5 min. In this study, one organic and three hybrid organic/inorganic coating solutions were applied to cold-rolled (CR) carbon steel. The coatings were then evaluated for corrosion resistance under a salt spray test. The coating solutions examined in this study consisted of urethane-only, urethane-Si, urethane-Si-Ti, and urethane-Si-Ti-epoxy. The results of the 7 h salt spray test showed that the urethane-Si-Ti and urethane-Si-Ti-epoxy coating solutions had superior corrosion resistance on CR steel.

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

Effects of NaCl/H3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (NaCl/H3PO4 내염화 처리가 라이오셀 섬유의 열 안정 및 내산화 특성에 미치는 영향)

  • Kim, Eun Ae;Bai, Byong Chol;Jeon, Young-Pyo;Lee, Chul Wee;Lee, Young-Seak;In, Se Jin;Im, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.25 no.4
    • /
    • pp.418-424
    • /
    • 2014
  • The improved thermal stability and anti-oxidation properties of Lyocell fiber were studied based on flame retardant treatment by using NaCl/$H_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various maxing ratio of NaCl and $H_3PO_4$ and the mechanism was proposed through experimental results of thermal stability anti-oxidation. The IPDT (integral procedural decomposition temperature), LOI (limited oxygen index) and $E_a$ (activation energy) increased 23, 30 and 24% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of Lyocell fiber were provided using NaCl/$H_3PO_4$ solution and the mechanism was also studied based on experimental results such as IDT (initial decomposition temperature), IPDT, LOI and $E_a$.

Fire Spreading Prevention of Straw-roofing House in Folk Village by Flame Resistant Treatment (민속마을 초가집의 방염에 의한 화재확산방지)

  • Park, Ho-Chun;Kim, Hwang-Jin;Lee, Seung-Hyun;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.52-57
    • /
    • 2010
  • Fire protection countermeasure were considered on the straw thatched roof and wooden structure. For the fire resistant treatment, rice straw was soaked in the fire resistant liquid with different soaking time. After treatment, some rice straw sample was washed with water then the rice straws were tested to check the fire resistance performance. And the wood was soaked in the fire resistant liquid at an atmospheric pressure, vacuum-pressure condition and painted with brush on the surface. To analyse the fire resistant performance of rice straw, ignition delay time was measured under the radiant heat flux of cone heater. And the fire resistant performance of wood samples were tested with 45 degree fire resistant test apparatus and cone heater. Based on the cone heater test, the rice straw which most easily ignitable material shows the longer ignition delay time than not treated ones and even in the water washed straw show a longer ignition delay time than not treated ones. And fire resistant treated woods of vacuum-pressure treated sample showed the most excellent performance on fire resistance. And the fire resistant treated by brush and soaking showed a longer ignition delay time than not treated ones. From this experiment, it was found that a fire resistant treatment of rice straw and wood of the house can be protected from the fire spread.

Adhesion of Model Molecules to Metallic Surfaces, the Implications for Corrosion Protection

  • de Wit, J.H.W.;van den Brand, J.;de Wit, F.M.;Mol, J.M.C.
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.50-60
    • /
    • 2008
  • The majority of the described experimental results deal with relatively pure aluminium. Variations were made in the pretreatment of the aluminum substrates and an investigation was performed on the resulting changes in oxide layer composition and chemistry. Subsequently, the bonding behavior of the surfaces was investigated by using model adhesion molecules. These molecules were chosen to represent the bonding functionality of an organic polymer. They were applied onto the pretreated surfaces as a monolayer and the bonding behavior was studied using infrared reflection absorption spectroscopy. A direct and clear relation was found between the hydroxyl fraction on the oxide surfaces and the amount of molecules that subsequently bonded to the surface. Moreover, it was found that most bonds between the oxide surface and organic functional groups are not stable in the presence of water. The best performance was obtained using molecules, which are capable of chemisorption with the oxide surface. Finally, it was found that freshly prepared relatively pure aluminum substrates, which are left in air, rapidly lose their bonding capacity towards organic functional groups. This can be attributed to the adsorption of contamination and water to the oxide surface. In addition the adhesion of a typical epoxy-coated aluminum system was investigated during exposure to water at different temperatures. The coating was found to quite rapidly lose its adhesion upon exposure to water. This rapid loss of adhesion corresponds well with the data where it was demonstrated that the studied epoxy coating only bonds through physisorptive hydrogen bonding, these bonds not being stable in the presence of water. After the initial loss the adhesion of the coating was however found to recover again and even exceeded the adhesion prior to exposure. The improvement could be ascribed to the growth of a thin oxyhydroxide layer on the aluminum substrate, which forms a new, water-stable and stronger bond with the epoxy coating. Two routes for improvement of adhesion are finally decribed including an interphasial polymeric thin layer and a treatment in boiling water of the substrate before coating takes place. The adhesion properties were finely also studied as a function of the Mg content of the alloys. It was shown that an enrichment of Mg in the oxide could take place when Mg containing alloys are heat-treated. It is expected that for these alloys the (hydr)oxide fraction also depends on the pre-treatment and on the distribution of magnesium as compared to the aluminium hydroxides, with a direct impact on adhesive properties.

Na3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (라이오셀의 열 안정 및 내산화 특성 향상을 위한 Na3PO4 내염화 처리)

  • Kim, Hyeong Gi;Kim, Eun Ae;Lee, Young-Seak;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.25-32
    • /
    • 2015
  • The improved thermal stability and anti-oxidation properties of lyocell fiber were studied based on flame retardant treatment by using $Na_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various concentrations of $Na_3PO_4$ and the mechanism was proposed through experimental results of thermal stability and anti-oxidation. The integral procedural decomposition temperature (IPDT), limiting oxygen index (LOI) and activation energy ($E_a$) increased 30, 160% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of lyocell fiber were provided using $Na_3PO_4$ solution and the mechanism was also studied based on experimental results such as initial decomposition temperature (IDT), IPDT, LOI and $E_a$.

Evaluation of Combustion gas during Fire Tests of Veneers Coated with Ammonium Salts (암모늄염으로 도포시킨 베니어판의 연소 시에 발생하는 연소가스 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.93-99
    • /
    • 2016
  • This study tested the combustion characteristics of veneer specimens coated with four kinds of ammonium salts. Each veneer specimen was coated three times with 20 wt.% ammonium salt solutions at room temperature. After drying, the combustion characteristics of the specimens coated with chemicals, were investigated using the cone calorimeter (ISO 5660-1, 2). The specimens coated with monoammonium phosphate (MAPP) and, diammonium phosphate (DMPP) showed a 6.7% and, 10.0%, lower mean heat release rate ($HRR_{mean}$), respectively, than that of the uncoated specimen. On the other hand, the specimens coated with MAPP showed a 15.7% higher $CO_{peak}$ production rate and the specimens coated with DAPP showed by 8.2% lower rate than that of the uncoated specimen. The veneer coated with ammonium sulfate (AMSF) and DAPP showed a 9.6% and 33.3% lower the peak smoke production rate ($SPR_{peak}$) than that of the uncoated specimen. In addition, the time to the peak smoke extinction area ($SEA_{peak}$) was delayed by 38.4% in the specimens coated with DAPP than the uncoated specimen. Therefore, DAPP inhibited the combustion properties of the veneer and showed a tendency to reduce smoke production.

Analysis of Water Cycle Effect according to Application of LID Techniques (LID 기법 적용에 따른 물순환 효과분석)

  • Lee, Jungmin;Lee, Yun;Choi, Jongsoo
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.411-421
    • /
    • 2014
  • At present, the development in rainwater management approach is still insufficient due to the numerous adverse effects of urbanization. Storm water management is being developed to restore the natural state of water cycle undergoing several processes which were hindered such as infiltration and evapotranspiration. Low Impact Development (LID) was established in order to reduce the negative effects of urbanization to our environment. These developments can be used to respond to the effects of climate change such as heat island phenomenon. The effects of the development of new town in the district plan with application of LID facilities were studied and reported. Typically, LID facilities were applied in small scale development and were rarely used in large-scale development. Most of studies, however, did not assessment the effects of large-scale development projects with LID application to the natural water cycle. This study was conducted to simulate the urban hydrologic cycle simulation on Asan-Tangjeong in Korea. This study may be used in urban hydrologic cycle simulation and establishment of an urban water management plan in the future. Lastly, this study generated a model using the recently updated SWMM5 which determined the hydrologic cycle simulation after installation of LID facilities.

Effect on the Temperature in Forest Dominant Vegetation Change (산림 우점식생 변화가 온도에 미치는 영향)

  • An, Mi-Yeon;Hong, Suk-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • This study investigated the effect of forest type changes in Daegu, the hottest city in Korea, on the land surface temperature (LST). The LST change by forest type was analyzed by 2scene of Landsat TM image from 1990 to 2007. The land cover types were classified into 4 types; forest areas, urban areas, cultivated areas and other areas, and water areas. The forest areas were further classified into the coniferous tree areas and the broadleaf tree areas. The result of the statistical analysis of the LST change according to the forest type showed that the LST increased when the forest was changed to the urban area. The LST increased by about $0.6^{\circ}C$ when a broadleaf tree area was changed to an urban area and about $0.2^{\circ}C$ when a coniferous tree area was changed to an urban area. This was the temperature change as the result of the simple type change for 17 years. The temperature change was larger when considering both cases of the forest type being retained and changed. The LST increased by $2.3^{\circ}C$ more when the broadleaf tree areas were changed to the urban areas than when broadleaf trees were maintained. The LST increased by $1.9^{\circ}C$ more when the coniferous tree areas were changed to the urban areas than when the coniferous tree areas were maintained. The LST increased by $0.4^{\circ}C$ more when the broadleaf tree areas were destroyed than when the coniferous tree areas were destroyed. The results confirmed that the protection of broadleaf trees in urban forests was more effective for mitigating climate change.

Study on Properties of Natural Adhesives with Lacquer for Ceramic Conservation (옻을 활용한 토기 복원용 천연 접착재료의 특성 연구)

  • Jeong, Se Ri;Kim, Eun Kyung;Yu, Jae Eun
    • Journal of Adhesion and Interface
    • /
    • v.12 no.4
    • /
    • pp.111-116
    • /
    • 2011
  • The characteristics of natural resin, sap of the lacquer tree were examined as an adhesive for the ceramic conservation since it has such outstanding properties like corrosion resistance against acid and alkali, heat-resistance, waterproof, antiseptic and protection against insects. In order to utilize raw lacquer as an adhesive not under the hardening conditions of lacquer like high humidity (RH 75 to 85%) and high temperature (120 to $170^{\circ}C$), but under normal condition, isinglass and animal glue were added to raw lacquer at certain ratio. In addition, the viscosity and the drying time were measured and their possibilities of application were also investigated through measurement of tensile and adhesive strength. As a result of experiment, it was possible to dry at room temperature and RH $50{\pm}5%$ to mix with raw lacquer and glue, and the drying time of sample with animal glue was faster than that of isinglass. Furthermore, the adhesion of sample with glue was increased more than raw lacquer. It seems to be possible to use the environmental friendly traditional adhesive for the ceramic conservation and restoration, if there are studies or examinations of safety of applications on objects and weathering resistance.