• 제목/요약/키워드: heat insulation property

검색결과 64건 처리시간 0.021초

그린팀버월 패널의 열전달 특성 (Heat transfer of green timber wall panels)

  • 김윤희;장상식;신일중
    • 농업과학연구
    • /
    • 제38권1호
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

마이크로 중공구를 이용한 자외선 경화 코팅 박막의 단열 특성 (Thermal Insulation Property of UV Cure Coatings Using Hollow Micro-Spheres)

  • 김남이;장영욱;김성우
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.621-626
    • /
    • 2012
  • 본 연구에서는 마이크로 기공의 중공구를 유기 고분자 수지와 복합화한 유/무기 하이브리드 물질을 제조하여 우수한 단열 성능을 갖는 코팅유리를 개발하고자 하였다. 유기 고분자 물질로는 투명성과 접착성이 우수한 6관능기의 우레탄 아크릴레이트(UP118), 3관능기의 trimethylolpropane triacrylate (TMPTA), 2관능기의 1,6-hexanediol diacrylate (HDDA), 광 개시제(Irgacure184) 등으로 구성된 자외선 경화형 수지를 사용하였다. 유리 및 실리카 중공구를 고분자 수지에 각각 10~40 vol%까지 첨가하여 얻어진 코팅 졸을 투명유리에 바(bar)코팅 방식으로 박막을 형성시킨 후 자외선 경화를 통해 최종 코팅유리를 제조하였다. 마이크로 중공구의 종류 및 함량이 제조된 코팅유리의 광 투과율, 열전도도, 접착성 및 표면 경도에 미치는 영향을 조사하였다. 복합물 코팅유리는 중공구가 과량 첨가되어도 우수한 접착성(5B)을 유지하였으며, 단열 성능은 각 중공구가 20 vol%만 함유되어도 뚜렷하게 향상된 결과를 나타냈다. 또한 실리카 중공구(SP)를 단열 재료로 사용하였을 경우 광 투과율 80 %의 투명 코팅유리를 얻을 수 있었다.

세라믹-금속 기반 LED 어레이 패키지의 저온동시소성시 휨발생 억제 연구 (Low Temperature Co-firing of Camber-free Ceramic-metal Based LED Array Package)

  • 허유진;김효태
    • 마이크로전자및패키징학회지
    • /
    • 제23권4호
    • /
    • pp.35-41
    • /
    • 2016
  • 고출력 LED 조명용 패키지를 제조함에 있어서 발열은 LED의 광출력과 수명에 매우 중요한 영향을 주는 인자로 알려져 있다. 본 연구에서는 가로등용 고출력 LED 패키지를 개발함에 있어서 효과적인 방열을 하기 위하여 방열효과가 상대적으로 우수한 구조인 chip-on-a-heat sink 구조를 가지는 세라믹-메탈 기반의 패키지를 제조하였다. 열확산 기능을 하는 heat sink 기판소재는 알루미늄 합금을, LED 어레이 회로를 형성하는 절연막으로는 저온동시소성용 glass-ceramics을 사용하였다. 특히 열처리 시 가장 이슈가 되는 세라믹-금속 하이브리드 패키지 기판의 휨을 억제하기 위한 수단으로서, glass-ceramic 절연막을 부분 코팅함으로써 휨현상을 용이하게 줄일 수 있게 되었다. 또한, LED 패키지의 방열특성의 향상 즉 열저항도 기존의 MCPCB 패키지나 전면 코팅형 절연막 패키지에 비해 훨씬 낮아지는 효과를 얻었을 뿐 아니라, 세라믹 코팅소재의 절감효과도 볼 수 있게 되었다.

복합 에멀젼 외장마감재 표면부의 화염 특성 (Flame Characteristics of Surface Part of Composite Emulsion Exterior Finishes)

  • 류화성;신상헌;송성용;김득모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2019
  • As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. The importance of external insulation methods is increasing due to the strengthening of insulation standards. Among the main materials used in the external insulation method, dry bit material is a finishing material composed of an organic binder and aggregate. When the fire occurs, the ignition of the surface part causes a direct fire on the thermal insulation material at the rear side when heat energy is concentrated. Therefore, it is important that the finishing material in dry insulation using a dry bit has a low fire spreading property in case of a fire and does not have a sustained combustion. The purpose of this study was to evaluate the fire spreadability by changing the internal fillers while using alkoxide-based acrylic emulsions, hybrid acrylic emulsions, and general acrylic emulsions in order to suppress the fire spreading properties of exterior finish materials.

  • PDF

내열성 실리콘 수지의 전기적 특성에 관한 연구 (A study on the electric properties of heat resistant silicone resin.)

  • 곽영순;조정수;박정후;김순태;김두환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.227-232
    • /
    • 1991
  • Silicone resin which is made from silicone(Si) is well known by its heat-resistant property. Its good heat-resistant enables silicons resin being used in high temperature (up to $200^{\circ}C$) heavy-dury environment for electric insulation. This paper has dealed with the electrical properties of silicone resin such as dielectric constant and tan ${\delta}$ with heat treatment temperature $(200^{\circ}C{\sim}450^{\circ}C)$. To investigate the electrical insulation of silicone resin, dielectric strength by A.C and anti-tracking properties under both AC and D.C have been performed.

  • PDF

커튼월 형태 및 단열재 형상에 따른 단열성능 분석에 관한 연구 (A Study on the Analysis of Insulation Performance according to Curtain Wall Type and Insulation Material Form)

  • 유남규;홍상훈;김해나;서은석;김봉주;정의인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.165-166
    • /
    • 2019
  • Curtain wall means a non-bearing wall that forms the outer walls of a building to divide the exterior and interior space. The increased use of curtain walls is diverse, including structural safety, watertightness, and wind pressure. As the government's energy conservation policy and the aim of zero-energy houses, the importance of heat reduction is also greatly increased. So, the study of monotony is constantly being conducted. Thus, in this study, insulation performance was analyzed through simulation according to the shape of curtain wall and the shape of insulation inside, and the purpose of this study was to provide basic data on the application of insulation criteria by energy saving design of buildings.

  • PDF

수분 흡수가 단열재의 열전도계수에 미치는 영향에 관한 연구 (A Study on the Effects of Water Absorption on the Thermal Conductivity of Insulation Materials)

  • 유성연;김태호
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.119-125
    • /
    • 2013
  • IInsulation material is generally used for preventing heat loss from heat transport fluids, and water absorption severely reduces the insulation property. The purpose of this study is to evaluate the amount of water absorption supplied by the pouring method and spraying method, to investigate the effects of water absorption on the thermal conductivity of an insulation material, and modeling the relation between water absorption and thermal conductivity. E-glass, a kind of glass fiber, and HYPERLITE, mainly composed of pearlite, are selected, to compare hygroscopic and insulation properties. E-glass is found to have much higher water absorptivity, compared to HYPERLITE. The thermal conductivity of the water-absorbed E-glass is increased by more than 150%, compared to that of no absorption, while variation of the thermal conductivity of HYPERLITE with water absorption is insignificant. A three-stage model of water absorption for thermal conductivity is developed, and the modeling results are found to be in good agreement with the experimental data.

세라믹스 처리된 나일론 직물의 원적외선 방사성능과 보온효과 (Far IR Emission and Thermal Properties of Ceramics Coated Nylon Fabrics)

  • 여숙영;이동화;김은애
    • 한국의류학회지
    • /
    • 제22권4호
    • /
    • pp.515-524
    • /
    • 1998
  • The purpose of this study was to evaluate the thermal properties of ceramics coated nylon fabrics by determining far infra-red emissive properties, heat storage/release and thermal insulation. Far IR emissivity and emissive power were measured for 7~ 140n at 50'C . Three types of ceramics such as cordierite with $\alpha$-alumina, a-alumina with titanium oxide and a-alumina were chosen as specimens. Cordierite with $\alpha$-alumina was chosen to treat on the fabrics due to the good emissive properties on the fabrics. Add-ons and contents of ceramics were analyzed for ceramics and/or polyurethane coated fabrics. For the physical properties, thickness and air permeability were measured. Results showed a difference in the emissive property between ceramics themselves and ceramics coated fabrics. In the ambient temperature, there was no diffenence in emissivity among the different ceramics contents. Thermography showed that when the fabric was heated with the light, surface mean temperatures of fabrics were increased as the contents of ceramics increased, and the heat storage property was confirmed. In case of same thickness and air permeability, the thermal insulation value increased as the contents of ceramics increased because of increasing heat storage and Far IR reflectivity. So there were absorption and heat storage of ceramics for Far IR from human and reflection to human between ceramics coated fabrics and human.

  • PDF

공동주택 외피의 열교영향을 고려한 상당열관류율 및 연간 에너지소비성능 평가 연구 (A study on the annual energy performance of apartment building with the equivalent U-value of envelope considering the effect of thermal bridges)

  • 김동수;윤종호;신우철;곽희열
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.41-46
    • /
    • 2012
  • The building envelope is important specially for saving energy consumption of residential buildings. but Apartment houses in Korea commonly have inside insulation system which have constantly arisen thermal bridges, the risk of heat loss, as a necessity. This study aims to evaluate integrated insulation performance according to the different shapes of external walls, adjacent to windows. The thermal performance analysis was carried out by Equivalent U-value and using the three-dimensional heat transfer computer simulation (TRISCO-RADCON), under nine different cases of comparing among three each of different bases(current standard model, 30percent energy saving model and 60percent energy saving model). The heating and the cooling load were also compared between two cases (standard U-value and Equivalent U-value) of three each of different bases, using the Building energy simulation which is based on DOE-2.1 analysis. As results, it turns out that if the Equivalent U-value is considered on the envelope analysis, the heat flow loss will be increasing more than the standard U-value, and if heat insulation property of the residential building reinforced rather than current, the rate of influences on the thermal bridges would be extremely expanded. In addition, it is shown that annual heating loads of the apartment house with applied Equivalent U-value substantially increased by more than 15 percent compared to those with the existing U-value, but annual cooling loads were negligibly affected.