• 제목/요약/키워드: heat exchangers

검색결과 853건 처리시간 0.025초

소듐냉각고속로 붕괴열교환기의 고온 설계 및 건전성 평가 (High-Temperature Design and Integrity Evaluation of Sodium-Cooled Fast Reactor Decay Heat Exchanger)

  • 이형연;어재혁
    • 대한기계학회논문집A
    • /
    • 제37권10호
    • /
    • pp.1251-1259
    • /
    • 2013
  • 본 연구에서는 소듐냉각 고속로 붕괴열교환기(DHX)의 고온 설계 및 크리프-피로 손상 평가를 수행하였다. 제 4 세대 소듐냉각 고속로의 능동 및 피동 잔열제거계통에 설치되는 DHX와 한국원자력연구원의 STELLA-1 시험루프에 설치된 DHX에 대해 상세설계 및 3D 유한요소해석을 수행하고, 동 결과에 기초하여 고온설계 기술기준인 ASME Section III Subsection NH와 RCC-MR 코드를 따라 크리프-피로 손상평가를 수행하였다. 크리프-피로 손상평가 결과에 기초하여 두 설계기준에 대해 비교 분석하고, 설계 기술기준의 보수성 이슈에 대해 토의하였다.

과열방지장치가 설치된 복합열원 난방시스템에 관한 연구 (A Study on Hybrid Heating System with Anti-Superheating Devices)

  • 박윤철;고광수;한유리
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.19-27
    • /
    • 2007
  • The previous study was conducted to develop an air source multi heat pump system that could be operated with the solar collector and air source heat exchangers as heat source of the system. There is a winter-sowing problems in air source multi heat pump system when the outdoor temperature goes down under freezing point. The winter-sowing problem was solved by adapting R-22 refrigerant as working fluid in the previous study. However, when the system operated at high temperature, another problems are come out such as overheating of the solar collector outlet which lead to the superheat of the compressor inlet of the heat pump system. The condition could deteriorates a compressor in some case. In this study, we installed the anti-superheating devices on the previously developed system. As results of system performance test, COP of the system with anti-superheating technique is 2.4. It is a little improved COP compare to previous study's 2.23. In the results of multi heat source heating system, during operating solar collector, COP is relatively high between $200\;W/m^2$ and $400\;W/m^2$ solar intensity. It is recommended to extend the study on performance optimization with balancing the solar collect and capacity of compressor at higher solar irradiation conditions.

비선형회귀모델을 이용한 히트펌프시스템의 열교환기 고장에 대한 고장감지 및 진단에 대한 연구 (Fault Detection and Diagnosis (FDD) Using Nonlinear Regression Models for Heat Exchanger Faults in Heat Pump System)

  • 김학수;김민수
    • 대한기계학회논문집B
    • /
    • 제35권11호
    • /
    • pp.1111-1117
    • /
    • 2011
  • 본 연구에서는 비선형회귀모델을 이용한 히트펌프시스템에서의 고장감지 및 진단 알고리즘을 개발하였다. 히트펌프시스템에 발생할 수 있는 다양한 고장요소 중, 열교환기 고장에 대한 연구를 수행하였다. 해석 식을 바탕으로 제작한 모델을 이용하여 총 4가지 작동 모드(무고장, 증발기 고장, 응축기 고장, 응축기와 증발기 고장)에 대한 시뮬레이션을 수행하였다. 고장감지 및 진단 알고리즘을 개발하기 위해 무고장모드에서의 데이터를 바탕으로 각 열교환기의 과열도 또는 과냉도를 예측할 수 있는 비선형회귀모델을 제시하였다. 고장감지 및 진단 알고리즘은 이 비선형회귀모델을 바탕으로 예측한 열교환기에서의 과열도 또는 과냉도 값과 시뮬레이션 값을 비교하여 그 차이의 정도에 따라 각 열교환기의 고장을 감지 및 진단하도록 하였다.

원형관 및 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 상관관계식 (Convective Heat Transfer Correlations for the Compact Heat Exchanger with Circular Tubes and Flat Tubes-Plate Fins)

  • 모정하
    • 대한기계학회논문집B
    • /
    • 제34권3호
    • /
    • pp.291-299
    • /
    • 2010
  • 본 연구에서는 열의 수가 세 개인 원형관 및 종횡비가 고려된 납작관-평판휜 형상의 밀집형 열교환기 내 공기의 유동 및 열전달 특성을 RNG $k-{\varepsilon}$ 난류모델을 적용하여 수치적으로 해석하였다. 수치조건의 범위는 원형관인 경우 1,000<$Re_D_h$<10,000이며, 납작관인 경우 1,000<$Re_{D_h}$<10,000 및 3.06$f\;=\;CRe^m_{D_h}$의 형태로, Colburn j 계수는 $j\;=\;CRe^m_{D_h}$ 형태로 상관관계식을 제시하였다. 이러한 상관관계식은 향후 원형관 및 납작관-평판휜 형상의 열교환기 설계시에 기본적인 자료로 충분히 활용될 수 있을 것으로 판단된다.

유전알고리즘과 ε-NTU 모델을 이용한 다양한 열교환기의 최적설계 및 성능해석 (Heat Exchanger Ranking Program Using Genetic Algorithm and ε-NTU Method for Optimal Design)

  • 이순호;김민성;하만영;박상후;민준기
    • 대한기계학회논문집B
    • /
    • 제38권11호
    • /
    • pp.925-933
    • /
    • 2014
  • 오늘날 고성능컴퓨터로 인해 많은 산업분야에서 전산해석이 사용되고 있다. 하지만 정해진 컴퓨터자원과 시간에 의해 3 차원 풀 스케일 해석에서는 많은 어려움 등이 있다. 본 연구에서 ${\varepsilon}-NTU$ 식과 열교환기 성능의 데이터베이스를 이용해 열교환기의 성능예측프로그램을 개발하였다. 다양한 타입의 열교환기 형상정보와 성능데이터베이스를 구축하였고, 이를 바탕으로 정해진 작동 조건에서 열교환기의 성능을 계산하였다. 계산된 정보를 바탕으로 최적의 사이즈를 갖는 형상을 찾기 위해 유전알고리즘(Genetic Algorithm)을 이용하였다. 계산을 위해 상용 소프트웨어인 MATLAB 과 REFPROP 이 사용되었다.

Analysis of critical fluid velocity and heat transfer in temperature-dependent nanocomposite pipes conveying nanofluid subjected to heat generation, conduction, convection and magnetic field

  • Fakhar, Mohammad Hosein;Fakhar, Ahmad;Tabatabaei, Hamidreza
    • Steel and Composite Structures
    • /
    • 제30권3호
    • /
    • pp.281-292
    • /
    • 2019
  • In this paper, analysis of critical fluid velocity and heat transfer in the nanocomposite pipes conveying nanofluid is presented. The pipe is reinforced by carbon nanotubes (CNTs) and the fluid is mixed by $AL_2O_3$ nanoparticles. The material properties of the nanocomposite pipe and nanofluid are considered temperature-dependent and the structure is subjected to magnetic field. The forces of fluid viscosity and turbulent pressure are obtained using momentum equations of fluid. Based on energy balance, the convection of inner and outer fluids, conduction of pipe and heat generation are considered. For mathematical modeling of the nanocomposite pipes, the first order shear deformation theory (FSDT) and energy method are used. Utilizing the Lagrange method, the coupled pipe-nanofluid motion equations are derived. Applying a semi-analytical method, the motion equations are solved for obtaining the critical fluid velocity and critical Reynolds and Nusselt numbers. The effects of CNTs volume percent, $AL_2O_3$ nanoparticles volume percent, length to radius ratio of the pipe and shell surface roughness were shown on the critical fluid velocity, critical Reynolds and Nusselt numbers. The results are validated with other published work which shows the accuracy of obtained results of this work. Numerical results indicate that for heat generation of $Q=10MW/m^3$, adding 6% $AL_2O_3$ nanoparticles to the fluid increases 20% the critical fluid velocity and 15% the Nusselt number which can be useful for heat exchangers.

열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험 (An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design)

  • 권정태;임효재;박경우;김창업;김경민;권영철
    • 에너지공학
    • /
    • 제17권1호
    • /
    • pp.1-7
    • /
    • 2008
  • 본 연구는 착상이 일어나는 조건에서 작은 사각 덕트내의 습공기의 층류유동에서 열 및 물질전달특성을 이해하고자 수행되었다. 알루미늄 평판이 열교환기의 핀부분을 모사하기 위하여 사용되었다. 알루미늄 표면온도는 착상조건에서의 열 및 물질전달 특성을 조사하여 해석하기 위하여 측정되었다. 또한 열교환기 공기측 채널에서 착상에 의한 air-blocking효과를 화인하기 위해 압력강하가 측정되었다. 그리고 착상조건에서 습공기의 국소 특성을 해석하기 위한 방법이 제시되었다.

LFG와 LNG 혼합연료의 조성에 따른 다관형 열교환기에서의 열전달 특성 (Heat Transfer Characteristics of Tube Bundle Type Beat Exchanger for LFG and LNG Mixed Fuel)

  • 전용한;김용;서태범
    • 에너지공학
    • /
    • 제15권1호
    • /
    • pp.45-51
    • /
    • 2006
  • 본 연구에서는 LFG와 LNG의 혼합연료의 연소가스측 열전달 특성을 LFG, LNG 단독 연료와 비교함으로써 실험적으로 연구하였다. 실험을 위하여 파일럿 연소시스템을 제작하였으며, 연소시스템의 열교환부에는 수직 수평 배플을 가지는 다관형 열교환기를 설치하였다. 실험은 연료 주입 방식, 저위발열량, 메탄의 조성(44.5%, 54.5%)의 서로 다른 조건에서 수행되었다. 본 연구를 통하여 동일한 레이놀즈 수에서 LNG의 연소가스측누셀트 수는 LFG보다 큼을 알 수 있었으며, LFG의 경우에 LFG와 LNG 혼합 연료가 LFC 단독 연료보다 큼을 확인하였다. 따라서, LFG를 사용하는 경우 LFG 단독 연료를 사용하기보다는 LFG에 LNG를 적절히 첨가시켜 사용하는 것이 열전달이 향상되며, 발생 LFG의 공급 불안정성을 완화하는데 기여할 수 있다고 판단된다.

수평형 지중열교환기 설계를 위한 토양 열전도도 예측 모델 평가 (Evaluation of Conventional Prediction Model for Soil Thermal Conductivity to Design Horizontal Ground Heat Exchanger)

  • 손병후;위지혜;한은선;임지희;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.813-824
    • /
    • 2010
  • Thermal conductivity of soils is one of the most important parameters to design horizontal ground heat exchangers. It is well known that the thermal conductivity of soil is strongly influenced by its density and water content because of soil's particulate structure. This paper reviewed and evaluated some of the commonly used prediction models for thermal conductivity of soils with the experimental data available in the literature. Semi-theoretical models for two-component materials were found inappropriate to estimate the thermal conductivity of dry state sands. It came out that the model developed by Cote and Konrad gave the best overall prediction for unsaturated sands available in the literature. Also, a parametric analysis is conducted to investigate the effect of thermal conductivity and water content, soil type on the horizontal ground heat exchanger design. The analysis shows that a required pipe length for the horizontal ground heat exchanger is reduced with the increase of soil thermal conductivity and water content. The calculation results also show that the dimension of the horizontal ground heat exchanger can be reduced to a certain extent by using backfilling material with a higher thermal conductivity of solid particles.

  • PDF

CO2 지열 히트펌프 사이클 모사에 관한 연구 (Studies on the Cycle Simulation for a Geothermal Heat Pump System using CO2 as Refrigerant)

  • 김영재;장근선
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2888-2897
    • /
    • 2011
  • 본 연구에서 개발된 정상상태 사이클 모사 프로그램을 통해 이산화탄소를 사용하는 지열 히트펌프 시스템의 성능을 고찰하였다. 내부열교환기를 포함하지 않는 기본 히트펌프 사이클의 성능에 대한 다양한 운전변수들의 영향을 조사하기 위해 매개변수 연구를 수행하였다. 시뮬레이션 프로그램은 실내기, 실외기, 압축기, 팽창밸브를 모사하는 포트란 서브루틴과 비주얼 베이식을 사용해 프로그램된 입력을 위한 전처리, 출력을 위한 후처리 프로세서를 포함하는 그래픽 인터페이스로 구성되어 있다. Refprop V6.01을 사용하여 이산화탄소의 열역학적 물성치와 상평형 거동을 계산하였다. 모사결과들의 신뢰성은 사례연구를 통한 실험데이터와의 비교를 통해 검증하였다. 본 연구에서 개발된 사이클 모사 프로그램은 이산화탄소 지열 히트펌프 시스템의 경제적이면서도 효율적인 운전조건들을 결정하고 최적화하는 데 있어 유용한 도구가 될 수 있을 것이다.