• 제목/요약/키워드: heat equivalent

검색결과 415건 처리시간 0.025초

9-12% Cr강의 용접부에 미치는 δ-ferrite의 영향 (The Effects of δ-ferrite on Weldment of 9-12% Cr Steels)

  • 안성용;강남현
    • Journal of Welding and Joining
    • /
    • 제31권6호
    • /
    • pp.8-16
    • /
    • 2013
  • As the energy consumption increases rapidly, power generation needs the high energy efficiency continuously. To achieve the high efficiency of power generation, the materials used have to endure the higher temperature and pressure. The 9-12%Cr steels possess good mechanical properties, corrosion resistance, and creep strength in high temperature due to high Cr contents. Therefore, the 9-12%Cr steels are widely used for the high-temperature components in power plants. Even though the steels usually have a fully martensitic microstructure, they are susceptible to the formation of ${\delta}$-ferrite specifically during the welding process. The formation of ${\delta}$-ferrite has several detrimental effects on creep, ductility and toughness. Therefore, it is necessary to avoid its formation. As the volume fraction of ${\delta}$-ferrite is less than 2% in microstructure, it has the isolated island morphology and causes no significant degradation on mechanical properties. For ${\delta}$-ferrite above 2%, it has a polygonal shape affecting the detrimental influence on the mechanical properties. The formation of ${\delta}$-ferrite is affected by two factors: a chemical composition and a welding heat input. The most effective ways to get a fully martensite microstructure are to reduce the chromium equivalent less than 13.5, to keep the difference between the chromium and nickel equivalent less than 8, and to reduce the welding heat input.

욕조의 보온성능연구 (A Performance Equation of Bath Tubs)

  • 이병호;서정일
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

폐기물 열분해과정에서 발생된 합성가스의 연소 특성 (Combustion Characteristics of Synthesis Gas Generated in Waste Pyrolysis Process)

  • 안용수;황상순;이성호;이협희
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.143-150
    • /
    • 2003
  • The synthesis gas generated in waste pyrolysis melting process which consists of pyrolysis of waste and melting process of ash is known to be an alternative fuel. Since the compositopn of synthesis gas is much different from other synthesis gases, the fundamental combustion characteristics are analyzed in this study. The radiation heat heat flux is used to estimate the heat flux from flames made by many combinations of fuel and oxidant supply. The results show that the synthesis gas needs much more amount of oxidant for equivalent heat flux to methane flame and the inverse diffusion flame type for synthesis gas burner is suitable for better radiation heat transfer.

  • PDF

원관내 맥동유동의 열전달에 관한 실험적 연구 (An Experimental Study on Heat Transfer in the Pulsating Pipe Flow)

  • 박희용;김창기
    • 설비공학논문집
    • /
    • 제3권1호
    • /
    • pp.78-85
    • /
    • 1991
  • An experimental result for heat transfer of pulsating turbulent pipe flow was presented under the condition of fully developed dynamic regime and uniform wall heat flux. Experiments were performed at following conditions ; Inlet time-averaged Reynolds number varied from 5000 to 11000; The peak pressure fluctuation were 1.3, 2.3 and 3.5 percent of the mean pressure; Pulsating frequency ranged from 53 Hz to 320 Hz The measurements showed that the effect of pulsation on local heat transfer is greater at downstream, in which pulsating source exists, than upstream and the heat transfer rate, averaged over the pipe length, was higher or lower than in an equivalent non-pulsating flow according to the pulsating conditions. In addition, the significant change of heat transfer rate was observed in acoustically resonant conditions, when the pulsating frequency of the flow corresponded to the pipe natural frequency.

  • PDF

대구지역 인공열의 시공간적 분포 추정에 관한 연구 (Estimation of the Temporal and Spatial Distribution of Anthropogenic Heat in Daegu)

  • 안지숙;김해동;홍정혜
    • 한국환경과학회지
    • /
    • 제11권10호
    • /
    • pp.1045-1054
    • /
    • 2002
  • Urban atmospheric conditions are usually settled as warmer, drier and dirtier than those of rural counterpart owing to reduction of green space and water space area heat retention in surfaces such as concrete and asphalt, and abundant fuel consumption. The characteristics of urban climate has become generally known as urban heat island. The purpose of this study is to investigate the temporal and spatial distribution of the heat emission from human activity, which is a main factor causing urban heat island. In this study, the anthropogenic heat fluxes emitted from vehicles and constructions are estimated by computational grid mesh which is divided by 1km $\times$ 1km. The anthropogenic heat flux by grid mesh can be applied to a numerical simulation model of the local circulation model. The constructions are classified into 9 energy-consumption types - hospital, hotel, office, department store, commercial store, school, factory, detached house and flat. The vehicles classified into 4 energy-consumption types - car, taxi, truck and bus. The seasonal mean of anthropogenic heat flux around central Daegu exceeded $50 W/m^2$ in winter. The annual mean anthropogenic heat flux exceeded $20 W/m^2$. The values are nearly equivalent to the anthropogenic heat flux in the suburbs of Tokyo, Japan.

Characteristics and Antioxidative Activity of Volatile Compounds in Heated Garlic (Allium sativum)

  • Woo, Koan-Sik;Yoon, Hyang-Sik;Lee, Youn-Ri;Lee, Jun-Soo;Kim, Dae-Joong;Hong, Jin-Tae;Jeong, Heon-Sang
    • Food Science and Biotechnology
    • /
    • 제16권5호
    • /
    • pp.822-827
    • /
    • 2007
  • The aroma characteristics and antioxidative activity of volatile compounds in heat-treated garlic (Allium sativum L.) were evaluated. The garlic was heated to various temperatures (100, 110, 120, and $130^{\circ}C$) for different lengths of time (1, 2, and 3 hr). The volatile compounds of heated garlic were extracted by simultaneous steam distillation extraction (SDE). Aroma compound profiles were analyzed by gas chromatography/mass spectrometry (GC/MS) and antioxidative activity was measured by 2,2-diphenyl-2-picrylhydrazyl (DPPH) assay and 2,2'-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid (ABTS) cation decolorization assay. The major aroma compounds were sulfur compounds such as dimethyl disulfide, 2-propen-1-ol, methyl-2-propenyl disulfide, dimethyl trisulfide, diallyl disulfide, methyl-2-propenyl trisulfide, and di-2-propenyl trisulfide. DPPH radical scavenging activity (EDA, %) and the ascorbic acid equivalent antioxidant activity (AEAC) of volatile compounds in heated garlic increased significantly with the increase of temperature and time (p<0.001). The EDA (%) and AEAC of raw garlic were 26.8%/10 mg garlic and 39.05 mg ascorbic acid equivalent per g sample. After heat treatment, the highest values were 40.50%/10 mg garlic for EDA (%) and 46.43 mg ascorbic acid equivalent per g sample for ABTS.

포장시 열영향 해석을 위한 등가열원의 적용성 (An Application of Equivalent Heat Source for Thermal Analysis of Pavement Process)

  • 이완훈;유병찬;정흥진
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.391-399
    • /
    • 2008
  • 강바닥판 포장에 사용되는 특수아스팔트 중의 하나인 구스아스팔트는 $240^{\circ}C$이상의 고온 상태에서 포설되기 때문에 시공중인 교량에 예상하지 못한 높은 온도와 이에 따른 열변형 및 열응력을 발생시킬 수 있다. 본 연구에서는 고온의 아스팔트 시공이 강바닥판에 미치는 열영향을 평가하고 이를 최소화하는 최적 포장공정을 찾기 위한 수치해석기법으로 등가열원을 이용한 열응력해석 기법을 제시하였다. 등가열원은 포장체 포설시의 열영향을 강상판 내부에서 발생하는 등가의 가상열원이다. 이를 이용하여 일반적인 구조해석 프로그램에서 구현하기 어려운 포장체의 포설에 의한 열전도, 열대류 등을 쉽게 모사할 수 있다. 포장 시공중 지점의 들림을 고려한 강상판 해석 및 다양한 포설 공정을 적용한 곡선교량해석을 통하여 등가열원방법의 적용성을 검토하였다.

BACKUP AND ULTIMATE HEAT SINKS IN CANDU REACTORS FOR PROLONGED SBO ACCIDENTS

  • Nitheanandan, T.;Brown, M.J.
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.589-596
    • /
    • 2013
  • In a pressurized heavy water reactor, following loss of the primary coolant, severe core damage would begin with the depletion of the liquid moderator, exposing the top row of internally-voided fuel channels to steam cooling conditions on the inside and outside. The uncovered fuel channels would heat up, deform and disassemble into core debris. Large inventories of water passively reduce the rate of progression of the accident, prolonging the time for complete loss of engineered heat sinks. The efficacy of available backup and ultimate heat sinks, available in a CANDU 6 reactor, in mitigating the consequences of a prolonged station blackout scenario was analysed using the MAAP4-CANDU code. The analysis indicated that the steam generator secondary side water inventory is the most effective heat sink during the accident. Additional heat sinks such as the primary coolant, moderator, calandria vault water and end shield water are also able to remove decay heat; however, a gradually increasing mismatch between heat generation and heat removal occurs over the course of the postulated event. This mismatch is equivalent to an additional water inventory estimated to be 350,000 kg at the time of calandria vessel failure. In the Enhanced CANDU 6 reactor ~2,040,000 kg of water in the reserve water tank is available for prolonged emergencies requiring heat sinks.

그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구 (Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling)

  • 김웅회;강은호;윤종호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

Evaluation of Non-Thermal Decontamination Processes to Have the Equivalence of Thermal Process in Raw Ground Chicken

  • Park, Eunyoung;Park, Sangeun;Hwang, Jeong Hyeon;Jung, Ah Hyun;Park, Sung Hee;Yoon, Yohan
    • 한국축산식품학회지
    • /
    • 제42권1호
    • /
    • pp.142-152
    • /
    • 2022
  • The present study was aimed at examining the antibacterial effects of nonthermal decontamination processes, which are equivalent to thermal treatment, to ensure microbiological safety of raw ground chicken. Escherichia coli or Salmonella were inoculated into 25 g of raw ground chicken samples. The raw ground chicken samples were non-treated or treated with high hydrostatic pressure (HHP) at 500 MPa (1-7 min), light-emitting diode (LED) irradiation at 405 nm wavelength (30-120 min), and heat at 70℃, 90℃ (1-60 min), and 121℃ (1-15 min). E. coli and Salmonella cell counts were enumerated after treatments. Moreover, the color parameters of treated raw ground chicken were analyzed. HHP treatment reduced E. coli and Salmonella cell counts by more than 5 Log CFU/g and more than 6 Log CFU/g after 7 min and 1 min, respectively; these effects were equivalent to those of thermal treatment. However, LED irradiation reduced Salmonella cell counts by only 0.9 Log CFU/g after 90 min of treatment, and it did not reduce E. coli cell counts for 90 min. Compared with those of the non-treated samples, the ΔE (total color difference) values of the samples treated with HHP were high, whereas the ΔE values of the samples treated with LED irradiation were low (1.93-2.98). These results indicate that despite color change by HHP treatment, HHP treatment at 500 MPa could be used as a non-thermal decontamination process equivalent to thermal treatment.