• Title/Summary/Keyword: heat detector

Search Result 122, Processing Time 0.024 seconds

A Study on Application of the Photo Detector for Electromagnetic Fuel Injection System of DI Diesel Engine (직분식 디젤기관 전자분사계의 광검출기 적용에 관한 연구)

  • Ra, Jin-Hong;Ahn, Soo-Kil
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.38-46
    • /
    • 1999
  • Increasing stringent emissions legislation and requirement of more effective energy used for diesel engine demand the fine control of the fuel injection system. Recently, the electromagnetic fuel injection control system for diesel engine is tried to realize the optimum diesel combustion by the feel back sensing as optical signal of combustion flame. The photo detectors were made for the feed back signal of electromagnetic fuel injection control for small DI diesel engine. Their abilities to detect defining combustion events were examined. By evaluating test results, it was shown that the wider acceptable optical range design of optical probe window face, and selection of installation position and installation method of detector were important point for improving sensing ability. The detector was shown to detect start and end of diffused combustion and maximum point of flame intensity impossible for pressure sensor, and also shown that the maximum point of flame intensity was 75% of accumulated heat release point within the experimental conditions.

  • PDF

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

A Study on Remote IoT operating time for Fire Detector of Smart Home (스마트 홈에서 연소에 따른 화재감지기 원격 IoT 작동 시간에 관한 연구)

  • Ko, Eun-young;Hong, Sung-Ho;Cha, Jae-sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.235-238
    • /
    • 2020
  • In the smart home era, fire safety is very important for human life and facility safety. Casualties and property damage from the fire would be a huge national loss. In this paper, we propose to predict the risk by determining the operating time of the fire detector according to the fire in the smart home. Among IoT fire detectors, heat detectors and smoke detectors, the risk can be predicted due to the difference in the operating time depending on the fire. Based on the results of this experiment, the ion-type smoke detector shows very fast characteristics, so it would be good to use the results in future fire prevention facility.

A Low-Power MPPT Interface for DC-Type Energy Harvesting Sources (DC 유형의 에너지 하베스팅 자원을 활용한 저전력의 MPPT 인터페이스)

  • Jo, Woo-Bin;Lee, Jin-Hee;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.35-38
    • /
    • 2018
  • This paper describes a low-power MPPT interface for DC-type energy harvesting sources. The proposed circuit consists of an MPPT controller, a bias generator, and a voltage detector. The MPPT controller consists of an MPG (MPPT Pulse Generator) with a schmitt trigger, a logic gate operating according to energy type (light, heat), and a sample/hold circuit. The bias generator is designed by employing a beta multiplier structure, and the voltage detector is implemented using a bulk-driven comparator and a two-stage buffer. The proposed circuit is designed with $0.35{\mu}m$ CMOS process. The simulation results show that the designed circuit consumes less than 100nA of current at an input voltage of less than 3V and the maximum power efficiency is 99.7%. The chip area of the designed circuit is $1151{\mu}m{\times}940{\mu}m$.

  • PDF

Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings (국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.533-538
    • /
    • 2014
  • This study examines the performance of and searches for improvements to the existing automatic fire detection systems installed at domestic apartment buildings as a basic study for development of intelligent fire detection systems specifically for apartments. Thus, this study aims to find out the problems in performance and maintenance of the existing fire detectors installed at apartment buildings which is the prerequisite process for development of intelligent fire detection system for that specific application. It is also found impossible to check whether or not the detectors installed at each apartment are in an operational state at normal times. This study finds that it is desirable to replace the slow-sensing heat detectors by a smoke and single smoke detectors which can detect a fire at its early stage in an effort to improve the problems of fire detectors installed at apartment buildings presently. Because we need to the independence fire detection system of apartment building.

The Analysis of Estrus Behavior and the Evaluation of Conditions Required for Improving Reproductive Efficiency in Holstein Dairy Cows using a Heat Detector (발정탐색기를 이용한 Holstein 젖소의 발정행동 분석 및 번식효율 향상을 위한 조건의 평가)

  • Baek, Kwang-Soo;Lee, Wang-Shik;Son, Jun-Kyu;Lim, Hyun-Joo;Yoon, Ho-Beak;Kim, Tae-Il;Hur, Tai-Young;Choe, Chang-Yong;Jung, Young-Hun;Kwon, Eung-Gi;Jung, Yeon-Sub;Kim, Sun-Kyu;Won, Jeong-Il
    • Journal of Embryo Transfer
    • /
    • v.28 no.3
    • /
    • pp.177-184
    • /
    • 2013
  • The objective of this study was to analyze the accuracy of estrus detection of heat detector and analysis of estrus behavior (mounting and mounted), and the evaluation of conditions required for improving reproductive efficiency in Holstein dairy cows fitted with a estrous detector. The heat detection system consists of estrous detector based on wireless sensor and an electric bulletin board displayed estrus behavior data. When cow mounting other cows, the accuracy of estrus behavior displayed an electric bulletin board were 87.5% (mounting other cows only), 100% (mounting other cows but not standing), 80.0% (mounting other cows with standing for 1~4 seconds), 90.0% (mounting other cows but not standing for 1~4 seconds), 80% (mounting other cows with standing for more than 5 seconds) and 90.0% (mounting other cows but not standing for more than 5 seconds). When cow mounted other cows, the accuracy of estrus behavior displayed an electric bulletin board were 100% (mounted other cows but not standing), 100% (mounted other cows with standing for 1~4 seconds), 100% (mounted other cows but not standing for 1~4 seconds) and 100% (mounted other cows with standing for more than 5 seconds). Circadian distribution of first observed in estrus were 59.1% (am 8~pm 6) and 40.9% (pm 6~am 8). Distribution for the number of estrus behavior were 40.9% (less than 3 times), 36.4% (4~6 times) and 22.7% (more than 4 times). The conception rates relative to interval from first estrus behavior to insemination for estrus periods were 23.1% (less than 11 hours) and 55.6% (12~20 hours).

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

Development of Non-Face-To-Face Heat Sensor Module for AI Automated Access Control System and Linkage with Education Program (AI 자동화 출입통제 시스템을 위한 비대면 발열 감지기 모듈 개발 및 교육 프로그램 연계)

  • Lee, Hyo-Jai;Kim, Eungsuk;Hong, Chang-Ho
    • Journal of Practical Engineering Education
    • /
    • v.13 no.2
    • /
    • pp.301-304
    • /
    • 2021
  • In this study, we developed a module that can perform two functions at the same time through interworking between a personal recognition module and a heat detection module in the era of COVID-19. This can simultaneously solve the problem of compatibility of the personal recognition module that occurs in the existing system and the problem of secondary infection that can occur during congestion due to the separate implementation of heat detection. Therefore, in this study, NFC and Bluetooth motherboards were developed, and an array-type non-contact temperature sensor was applied to detect heat. The developed system is expected to be able to realize both access control of floating population and effective quarantine at the same time in public institutions or private companies that require AI automated access control. In addition, it is judged that it is possible to link the embedded programming and web programming implementation method using the module of the development system to the educational program.

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.