• 제목/요약/키워드: head weight

검색결과 822건 처리시간 0.027초

목표중량 근사치 자동 설정을 위한 멀티헤드 조합시스템에 관한 연구 (A Study on Automated Multi-Channel Combination System for the Closest Target Weight)

  • 안용우;반갑수
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.77-83
    • /
    • 2015
  • This paper is a study of the functions required for the system to quantify the closest target weight by combining several random weights such as chips, snacks, fruits, and vegetables. The multi-head weigher is designed for high-performance applications requiring increased production rates and tight accuracy tolerances. This combination system has 12 heads considered in the form of a rectangular array of $2{\times}6$ or $3{\times}4$. Channel combination can usually occur between 1 and n, and the frequency was the highest with two or three combinations. Experimental result of a combination system for a total target weight was measured at the range from 100g to 500g by increments of 50g, and the average success rate was about 70%. The average elapsed time was about 1.7 seconds, which means it can be used for the packaging of agricultural products with a variety of items.

담수산어류의 혈청단백질에 미치는 환경수의 영향(I) (The Effect of External Medium on Serum Protein of Fresh Water Fish(I))

  • 이용억;김익태
    • 한국동물학회지
    • /
    • 제8권2호
    • /
    • pp.28-32
    • /
    • 1965
  • It is well known that many kinds of chemical or metalic agent which were ionized or undissociated at toxified external medium and remarkable effect occurred to the fresh water fish. The effects of hydrogen ion concentration on serum protein of fresh water fish, (phycephalus argus CANTOR) had not been reported yet. In this point, authors attempted to study the changes of A/G ratio, total protein, hemoglobin, hematocrit, RBC , liver and kidney weight of snake head in the above environment. 95 snake heads were subjected to external medium with PH-4.5 and A/G ratio, hematocrit, hemoglobin, total protein, RBC, and liver & kidney weight were measured at 32.80, 15202000 and 272 hours respectively. In whole experimental period, L 1 and L2 globulin increased, on the other, albumin decreased as compare with control . Hence, the A/G ratio decreased remarkably . Though, total protein increased prominently through the whole experimental period, hematocrit, hemoglobin, RBC, increased only at 80 hours, and then decreased as compared to the control. Liver weight revealed distinctive increase at 80 hours, but no remarkable change could be seen there after. Hence, kidney weight revealed continuous rise. By these results, it may be said that as snake head were subjected to external medium with PH-4.5, this environmental factor influenced protein metabolism , blood component and organs.

  • PDF

두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발 (Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy)

  • 심재구;송기원;김진만;박명환
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.43-50
    • /
    • 2014
  • 두경부암 환자의 헤드 홀더를 사용하는 경우 모의 치료 시 환자는 테이블 위에 위치하지만, 방사선 치료를 시행하는 경우 헤드 홀더를 치료 테이블에 걸쳐서 사용하기 때문에 체중 및 여러 가지 요소로 인한 기하학적 불일치로 상, 하, 좌, 우 및 처짐의 현상이 발생할 수 있다. 이러한 환자 Set-Up의 재현성의 불일치를 개선하기 위해 두경부암 전용 헤드 홀더를 자체 고안하여 제작 및 개발하여 유용성을 평가하였다. Alderson Rando Phantom을 이용하여 전산화단층촬영장치(High Advantage, GE, U.S.A)를 통해 이미지를 획득하였고, 광자선 4MV 세기변조 방사선치료(IMRT) 방식을 적용하여 최적화된 치료 계획을 실시하였다. 선형가속기(21EX, Varian, U.S.A)를 이용하여 모의 치료와 동일한 상태에서 환자를 set-up한 후 에 치료기에 장착된 CBCT를 이용하여 각각의 무게(0,15,30Kg)의 차이를 통해 교정 전, 후 X, Y, Z축의 오차를 5회 반복 측정한 결과는 다음과 같다. 0Kg에서 $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0mm으로 나타났고, 교정 후에는 $0.2{\pm}0.8mm$, $0.4{\pm}0.5mm$, 0으로 나타났다. 15Kg에서 교정 전,후 오차는 $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.2{\pm}0.4mm$$0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$로 나타났다. 30Kg에서 교정 전,후 오차는 $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$$0.6{\pm}0.54mm$, $1{\pm}0mm$, $0.6{\pm}0.5mm$로 나타났다. 각각의 교정 전,후의 통계적으로 분석한 결과 15Kg인 경우 Z축에서 p<0.034, 30Kg인 경우 Y, Z축에서 p<0.038, p<0.041 로 유의한 결과를 나타냈다. 두경부암 전용 방향 조절 장치 헤드 홀더가 환자의 set-up오차를 줄여주는 역할을 해주는 것으로 나타났다. 또한 오차를 줄여줌으로써 환자의 재현성이 향상되어 보다 정밀하고 정확한 방사선 치료를 구현할 수 있을 것으로 사료된다.

'충전식 전기예초기' 혜드 부분의 개선 (Improvement of a Head Part of 'Chargable Electric Weeder')

  • 오세훈;심재현;남원기
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2006년도 동계 학술대회 논문집
    • /
    • pp.31-34
    • /
    • 2006
  • Purposes of this research are convenience of manufacture, quality sophistication and reduction of a/s' ratio by that improve several shortcomings of existing steel housing The Housing of head is changed existent steel housing to ABS (acrylonitrile butadiene styrene) copolymer housing and its shape is changed. It does not need that paint housing by paint. so We may not care scar at storage or manufacture. The fast work speed and A/S is possible by combining a safety plate and a housing by volt and spring washer. When disjoint head part, there is no damage of safety plate and housing. Noise is disappeared by resonance phenomenon in early rpm at motor moving. When neck part of housing and a middle pipe are connected by drill nasa, the work is easier Also, there is sense of security little more catching motor in housing The improvement accomplished much improvements including light weight of head part.

  • PDF

Analysis of Stability on Single-leg Standing by Wearing a Head Mounted Display

  • Woo, Byung Hoon
    • 한국운동역학회지
    • /
    • 제27권2호
    • /
    • pp.149-155
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: $24.5{\pm}2.6years$, height: $175.0{\pm}6.4cm$, weight: $69.2{\pm}5.1kg$) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.

CATV Head/End용 Up-Converter의 개발 (A Study on the Development of Up-Converter for CATV Head/End Application)

  • 임경택
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 2002년도 춘계학술대회 논문집
    • /
    • pp.62-68
    • /
    • 2002
  • 본 논문은 CATV Head/End에 사용되는 54∼750 MHz용 업 컨버터(Up-Converter)글 개발하였다. 업 컨버터를 구성하는 증폭기, 주파수 혼합기, 전압제어 발진기 등 핵심 회로들을 개별적으로 설계 제작하고, 이들 각 회로를 전체 모듈에 적용하여 기구물 안에 구현할 수 있도록 하여 소형, 경량을 실현하였으며, 고주파 대역에서 적절한 차폐기술을 확보하는데 주안점을 두었다.

  • PDF

해바라기 수집종의 작물학적 특성 (Agronomic Characteristics of Sunflower (Helianthus annuus L.) Collections)

  • 김인재;남상영;이윤호;김성진;최성열;노창우;이정관;송인규;김홍식
    • 한국자원식물학회지
    • /
    • 제23권1호
    • /
    • pp.1-6
    • /
    • 2010
  • 농촌진흥청 국립농업유전자원센터로부터 국내외에서 수집된 해바라기 328종을 분양받아 바이오디젤 가능 작물로서 특성을 조사한 바 그 결과는 다음과 같다. 해바라기 수집종의 출아소요일수는 7~12일이었으며, 개화 소요일수는 55~86일로 폭넓게 분포하였다. 수집종 해바라기의 경장은 평균이 259 cm로 그 분포는 131~345 cm의 변이를 보였고, 성숙일수는 평균 35일이었다. 주당 두화수(頭花數)는 1개~23개로 큰 변이를 보였으며, 두화의 크기는 평균 17.6 cm 로 14.7~21.3 cm가 72.8%로 가장 높게 분포하였다. 두화당 종자수는 평균 1,430개 정도, 종실중은 평균 91.4 g로 28~379 g로 넓은 분포를 보였다. 종실길이는 평균 11.7 mm, 범위는 9.0~21.5 mm 이었으며, 종실 폭은 평균 6.4 mm, $1\;{\ell}$ 무게는 평균 322.5 g이었으며, 천립중은 평균 63.3 g, 주당 종실중은 평균 204 g이었다. 생육 및 종실 특성 중에서 두화 당 종자수의 변이가 가장 컸고, 다음으로 주당종실 중의 변이가 컸다. 수집종들의 형질 간 상관분석 결과, 경장이 클수록 종실폭은 커지고 개화일수도 길어졌으나, 성숙일수와 생육일수는 짧았다.

Association of head circumference with cognitive decline and symptoms of depression in elderly: a 3-year prospective study

  • Kwon, Oh Dae;Choi, So-Young;Bae, Jisuk
    • Journal of Yeungnam Medical Science
    • /
    • 제35권2호
    • /
    • pp.205-212
    • /
    • 2018
  • Background: Brain volume is associated with dementia and depression in the elderly. An easy way to predict relative brain volume is to measure head circumference. In this study, we investigated the relationship between head circumference and cognition as well as depression in a non-demented elderly community. Methods: Baseline and follow-up surveys were conducted in 2007 and 2010. At baseline, community residents aged 65 years or over (n=382) within a rural area of South Korea were screened for dementia and symptoms of depression and were followed using the same screening battery after 3 years (n=279). Data from anthropometric measurements (head circumference, height, and body weight), demographics, and blood tests were gathered. Neuropsychological tests, including the Korean version of mini-mental state examination (K-MMSE), clinical dementia rating (CDR) including the CDR-sum of boxes, the Korean version of instrumental activities of daily living, and geriatric depression scale (GDS), were performed. None of the 279 subjects followed were demented. Results: Baseline performance on the K-MMSE and GDS was poorer for participants with smaller head circumferences. Follow-up performance on the MMSE was also poorer for participants with smaller head circumferences. Interestingly, participants with smaller head circumference showed worse GDS scores at baseline but on follow-up examination, participants with larger head circumference showed rapid worsening than those with smaller head circumference with marginal significance by ANOVA test. In regression coefficient analysis, GDS decline showed significant difference. Conclusion: Head circumference was not associated with cognitive change but was associated with symptoms of depression in non-demented community residents.

자탈형 콤바인용 벼 무게 측정시스템 개발 (Development of a Rice Weighing System for Head-Feed Combine)

  • 이충근;최용;전현종;김학진;이상봉;류찬석
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.332-338
    • /
    • 2007
  • Yield mapping is necessary for precision farming. An on-site rice weighing system for a head-feed combine was developed to measure the total weight of rice grain harvested while the combine was operated. A load cell system was used to monitor rice weights accumulated into the combine grain tank using a load cell. This method gave cumulative grain weight readings as a function of time. The system consisted of a load cell, two supporting brackets, and a computer-based data acquisition system. The weights measured with the system from two fields were compared with those obtained with a commercially available electronic balance. The response of the load cell to varying grain weights was linearly modeled, showing a coefficient of determination of 0.998 and a standard error of ${\pm}4.09kg$.

전향성 골수내 K-강선을 이용한 중족골 두 및 경부 골절의 비관혈적 정복 및 고정술(6예 보고) (Closed Reduction and Fixation of Metatarsal Head and Neck Fractures Using Antegrade Intramedullary K-wire (6 Cases Report))

  • 김형년;임희준;박용욱
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.91-94
    • /
    • 2009
  • Metatarsal head and neck fractures are injuries that often result from a direct blow of a heavy objects to the metatarsal head. The head is often impacted or displaced to the plantar aspect that if not treated may cause malunion which later induces painful plantar calluses. If the fracture fragment is large enough, closed reduction may be successfully performed, but when the fragment is small or closed reduction is unsuccessful, open reduction is needed. We present our reduction and fixation technique for the metatarsal head and neck fractures using antegrade intramedullary Kirschner wire (K-wire) without opening the fracture site or infringing the metatarsophalangeal (MTP) joint which allows immediate motion of the joint and partial weight bearing in a stiff soled shoe.

  • PDF