• Title/Summary/Keyword: head weight

Search Result 822, Processing Time 0.024 seconds

A Study on Automated Multi-Channel Combination System for the Closest Target Weight (목표중량 근사치 자동 설정을 위한 멀티헤드 조합시스템에 관한 연구)

  • Ahn, Yong-Woo;Ban, Kap-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.77-83
    • /
    • 2015
  • This paper is a study of the functions required for the system to quantify the closest target weight by combining several random weights such as chips, snacks, fruits, and vegetables. The multi-head weigher is designed for high-performance applications requiring increased production rates and tight accuracy tolerances. This combination system has 12 heads considered in the form of a rectangular array of $2{\times}6$ or $3{\times}4$. Channel combination can usually occur between 1 and n, and the frequency was the highest with two or three combinations. Experimental result of a combination system for a total target weight was measured at the range from 100g to 500g by increments of 50g, and the average success rate was about 70%. The average elapsed time was about 1.7 seconds, which means it can be used for the packaging of agricultural products with a variety of items.

The Effect of External Medium on Serum Protein of Fresh Water Fish(I) (담수산어류의 혈청단백질에 미치는 환경수의 영향(I))

  • 이용억;김익태
    • The Korean Journal of Zoology
    • /
    • v.8 no.2
    • /
    • pp.28-32
    • /
    • 1965
  • It is well known that many kinds of chemical or metalic agent which were ionized or undissociated at toxified external medium and remarkable effect occurred to the fresh water fish. The effects of hydrogen ion concentration on serum protein of fresh water fish, (phycephalus argus CANTOR) had not been reported yet. In this point, authors attempted to study the changes of A/G ratio, total protein, hemoglobin, hematocrit, RBC , liver and kidney weight of snake head in the above environment. 95 snake heads were subjected to external medium with PH-4.5 and A/G ratio, hematocrit, hemoglobin, total protein, RBC, and liver & kidney weight were measured at 32.80, 15202000 and 272 hours respectively. In whole experimental period, L 1 and L2 globulin increased, on the other, albumin decreased as compare with control . Hence, the A/G ratio decreased remarkably . Though, total protein increased prominently through the whole experimental period, hematocrit, hemoglobin, RBC, increased only at 80 hours, and then decreased as compared to the control. Liver weight revealed distinctive increase at 80 hours, but no remarkable change could be seen there after. Hence, kidney weight revealed continuous rise. By these results, it may be said that as snake head were subjected to external medium with PH-4.5, this environmental factor influenced protein metabolism , blood component and organs.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Improvement of a Head Part of 'Chargable Electric Weeder' ('충전식 전기예초기' 혜드 부분의 개선)

  • Oh, Se-Hun;Shim, Jae-Hyeon;Nam, Won-Ki
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • v.11 no.1
    • /
    • pp.31-34
    • /
    • 2006
  • Purposes of this research are convenience of manufacture, quality sophistication and reduction of a/s' ratio by that improve several shortcomings of existing steel housing The Housing of head is changed existent steel housing to ABS (acrylonitrile butadiene styrene) copolymer housing and its shape is changed. It does not need that paint housing by paint. so We may not care scar at storage or manufacture. The fast work speed and A/S is possible by combining a safety plate and a housing by volt and spring washer. When disjoint head part, there is no damage of safety plate and housing. Noise is disappeared by resonance phenomenon in early rpm at motor moving. When neck part of housing and a middle pipe are connected by drill nasa, the work is easier Also, there is sense of security little more catching motor in housing The improvement accomplished much improvements including light weight of head part.

  • PDF

Analysis of Stability on Single-leg Standing by Wearing a Head Mounted Display

  • Woo, Byung Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the effects of three visual conditions (eyes opened, eyes closed, and wearing of a head mounted display [HMD]) on single-leg standing through kinematics and kinetic analysis. Method: Twelve college students (age: $24.5{\pm}2.6years$, height: $175.0{\pm}6.4cm$, weight: $69.2{\pm}5.1kg$) participated in this study. The study method adopted three-dimensional analysis with six cameras and ground reaction force measurement with one force plate. The analysis variables were coefficient of variation (CV) of the center of body mass, head movement, ground reaction force, and center of pressure, which were analyzed using one-way analysis of variance with repeated measures according to visual conditions. Results: In most cases, the results of this study showed that the CV was significantly higher in the order of HMD wearing, eyes closed, and eyes opened conditions. Conclusion: Our results indicated that body sway was the largest in the HMD wearing condition, and the risk of falling was high owing to the low stability.

A Study on the Development of Up-Converter for CATV Head/End Application (CATV Head/End용 Up-Converter의 개발)

  • 임경택
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.62-68
    • /
    • 2002
  • In this paper, we have developed the Up-Convertor for CATV Head/End using 54∼750 MHz. We have individually designed and fabricated the main circuit of Up-converter such as Amplifier, frequency mixer, Voltage Controlled Oscillator(OSC), and we have realized the implementation for System Module in each circuit, so we have achieved a small size, light weight. and we have focused to have a shielding technique in high frequency bandwidth.

  • PDF

Agronomic Characteristics of Sunflower (Helianthus annuus L.) Collections (해바라기 수집종의 작물학적 특성)

  • Kim, In-Jae;Nam, Sang-Young;Lee, Yun-Ho;Kim, Seong-Jin;Choi, Seong-Yel;Rho, Chang-Woo;Lee, Jung-Gwan;Song, In-Gyu;Kim, Hong-Sig
    • Korean Journal of Plant Resources
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • To evaluate agronomic characteristics for the use of biodiesel crop, 328 collections of sunflower (Helianthus annus L.) were obtained from Genebank in Rural Development Adminstration (RDA). The necessary days from seeding to emergence of collections were from 7 to 12 days, and the days to flowering were widely distributed from 55 to 86 days. Stem length ranged from 131 to 345 cm with a mean of 259 cm, and the mean maturing days were 35 days. The number of head flower was 1~23 ea per plant, and the mean size of head flower was 17.6 cm with a range from 14.7 to 21.3 cm (72.8%). The mean seed number per head flower was 1,430 ea, and the weight of seed per plant ranged from 23 to 379 g with a mean of 91.4 g. The mean seed length was 11.7 mm with a range from 9.0 to 21.5 mm, and the mean diameter was 6.4 mm. The mean weight of seed per litter, 1000 grain weight and seed weight per plant were 322.5 g, 63.3 g and 204 g, respectively. Variation of number of head per plant was largest and weight of grain per plant was large in next among growth and grain characteristics. At the results of correlation analysis among characteristics, the seed diameter was getting bigger and the days for flowering dates were prolonged in the higher stem length plant, but the days to maturing and growth duration was shortened.

Association of head circumference with cognitive decline and symptoms of depression in elderly: a 3-year prospective study

  • Kwon, Oh Dae;Choi, So-Young;Bae, Jisuk
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.2
    • /
    • pp.205-212
    • /
    • 2018
  • Background: Brain volume is associated with dementia and depression in the elderly. An easy way to predict relative brain volume is to measure head circumference. In this study, we investigated the relationship between head circumference and cognition as well as depression in a non-demented elderly community. Methods: Baseline and follow-up surveys were conducted in 2007 and 2010. At baseline, community residents aged 65 years or over (n=382) within a rural area of South Korea were screened for dementia and symptoms of depression and were followed using the same screening battery after 3 years (n=279). Data from anthropometric measurements (head circumference, height, and body weight), demographics, and blood tests were gathered. Neuropsychological tests, including the Korean version of mini-mental state examination (K-MMSE), clinical dementia rating (CDR) including the CDR-sum of boxes, the Korean version of instrumental activities of daily living, and geriatric depression scale (GDS), were performed. None of the 279 subjects followed were demented. Results: Baseline performance on the K-MMSE and GDS was poorer for participants with smaller head circumferences. Follow-up performance on the MMSE was also poorer for participants with smaller head circumferences. Interestingly, participants with smaller head circumference showed worse GDS scores at baseline but on follow-up examination, participants with larger head circumference showed rapid worsening than those with smaller head circumference with marginal significance by ANOVA test. In regression coefficient analysis, GDS decline showed significant difference. Conclusion: Head circumference was not associated with cognitive change but was associated with symptoms of depression in non-demented community residents.

Development of a Rice Weighing System for Head-Feed Combine (자탈형 콤바인용 벼 무게 측정시스템 개발)

  • Lee, C.K.;Choi, Y.;Jun, H.J.;Kim, H.J.;Lee, S.B.;Ryu, C.S.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.5
    • /
    • pp.332-338
    • /
    • 2007
  • Yield mapping is necessary for precision farming. An on-site rice weighing system for a head-feed combine was developed to measure the total weight of rice grain harvested while the combine was operated. A load cell system was used to monitor rice weights accumulated into the combine grain tank using a load cell. This method gave cumulative grain weight readings as a function of time. The system consisted of a load cell, two supporting brackets, and a computer-based data acquisition system. The weights measured with the system from two fields were compared with those obtained with a commercially available electronic balance. The response of the load cell to varying grain weights was linearly modeled, showing a coefficient of determination of 0.998 and a standard error of ${\pm}4.09kg$.

Closed Reduction and Fixation of Metatarsal Head and Neck Fractures Using Antegrade Intramedullary K-wire (6 Cases Report) (전향성 골수내 K-강선을 이용한 중족골 두 및 경부 골절의 비관혈적 정복 및 고정술(6예 보고))

  • Kim, Hyong-Nyun;Lim, Hee-Joon;Park, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.91-94
    • /
    • 2009
  • Metatarsal head and neck fractures are injuries that often result from a direct blow of a heavy objects to the metatarsal head. The head is often impacted or displaced to the plantar aspect that if not treated may cause malunion which later induces painful plantar calluses. If the fracture fragment is large enough, closed reduction may be successfully performed, but when the fragment is small or closed reduction is unsuccessful, open reduction is needed. We present our reduction and fixation technique for the metatarsal head and neck fractures using antegrade intramedullary Kirschner wire (K-wire) without opening the fracture site or infringing the metatarsophalangeal (MTP) joint which allows immediate motion of the joint and partial weight bearing in a stiff soled shoe.

  • PDF