• Title/Summary/Keyword: head shapes

Search Result 164, Processing Time 0.028 seconds

The evaluation of effectiveness of 3DCA using vacuum bag(Vac-Lock) for patient immobilization device (3DCA제작을 통한 Vac-Lock 사용시 효율성향상에 대한 연구)

  • Lee YoungChul;Lee ChulBin;Kang NoHyun;Kim DongEuk;Lee JungYong;Jeong InPyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.67-72
    • /
    • 2004
  • Purpose : Patient immobilization is crucial factor for radiation therapy. Generally, we have been used vacuum bag immobilization device(Vac-Lock) for whole body immobilization. In order to easily set up of vacuum bag(Vac-Lock), we made a 3DCA(3-Dimensional Conformal Accessary). The purpose of this study is evaluation of effectiveness of 3DCA using Vack-Lock for patient immobilization. Materials and Methods : We made 3DCA(3-Dimensional Conformal Accessary) tool of wooden boards. The reasons to choice of wooden boards are its easily handling nature and cheap expenses. Results : (1) We reduced man power from $5{\sim}6$persons to 1person to make immobilizations, (2) Shortened work time from 1hour to within 10minutes. (3) Avoid a collision to treatment gantry head. (4) Its shapes are smart and clean. Conclusion : We have made and used 3DCA(3-Dimensional Conformal Accessary) tool was very effective and convenience for the patients and users.

  • PDF

The Study on Standard Bodytype for Korean Women between the ages of 18 and 24 years old(Part I) -focusing on the analysis of the High-frequency type and the High-frequency range- (18~24세 한국인 여성의 표준체형에 관한 연구(제1보) -다빈도유형 및 다빈도구간에 대한 분석을 중심으로-)

  • 이정임;남윤자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.5
    • /
    • pp.630-641
    • /
    • 2002
  • The purpose of this study is to suggest the standard of bodytype which offers various data with regard to three-dimensional characteristics of body, and which offers the criterion for the sizes and shapes to interpret various bodytypes, to estimate filling, and to construct ready-made clothing. In this study, standard bodytype was defined as a typical type with beautiful proportion and shape which a large number of people have, too. In order to continue this study, there were two ways of analyzing bodytypes of subjects in the view of statistics and beauty. We primarily carried on statistical analysis in this report. Taken as a sample, the subjects were ninety-seven females who were between the ages of 18 and 24 years o1d. They were measured on November 1999. The data of seven hundred and few females, 18∼24 year-old, from the National Somatometry Survey of 1997 were used for analysis, too. Three kinds of classification methods were used for statistical analysis. The first method was based on the lateral view of the body, the second was based on the Factor and Cluster analysis of the photographic measurements of each of the anterior and lateral body, and the third was based on the Factor and Cluster analysis of the anthropometric measurements of the whole body. From the analysis on the distribution of R hrer Index the difference of width, the difference of depth, the proportion of height and head height, the High-frequency Proportion(H.P.)range were selected. The straight type from the lateral view, High-frequency type from each method, and subjects in H.P. range were compared with each other. As the result, it was confirmed that it is proper to base on the size and shape of subjects in H.P. range to analyze the standard bodytype.

3-Dimensional Verification Technique for Target Point Error (자기공명영상기반 겔 선량측정법을 이용한 3차원적 목표 중심점 점검기술)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • For overall system test, hidden-target test have been used using film which leads to inherent analysis error. The purpose of our study is to quantify this error and to propose gel dosimeter based verification technique for 3-dimensional target point error. The phantom was made for simulation of human head and this has ability to equip 10 gel-dosimeter. $BANGkit^{TM}$ which we are able to manufacture whenever it is needed as well as to easily change the container with different shapes was used as a gel dosimeter. The 10 targets were divided into two groups based on shapes of areas with a planned 50% isodose line. All treatment and analysis was performed three times using Novalis and $BrainSCAN^{TM}$. The target point error is $0.77{\pm}0.15mm$ for 10 targets and directional target point error in each direction is $0.54{\pm}0.23mm$, $0.37{\pm}0.08mm$, $0.33{\pm}0.10mm$ in AP (anterior-posterior), LAT (lateral), and VERT (vertical) direction, respectively. The result of less than 1 mm shows that the treatment was performed through each precise step in treatment procedure. In conclusion, the 3-dimensional target point verification technique can be one of the techniques for overall system test.

A Method for Establishing Chronology of Cloud Patterns Based on the Cover Patterns of Oegyujanggak Uigwe Books in the Late Joseon Period (외규장각 의궤 책의 문양을 통한 운보문 편년 설정 방법)

  • Lee, Eunjoo
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.4
    • /
    • pp.18-37
    • /
    • 2019
  • This study derived a method for establishing the chronology of cloud patterns by examining the arrangement of the treasure motifs in the cloud pattern used in the relevant pattern-decorated book covers of 89 Oegyujanggak Uigwe books, which are currently housed in the National Museum of Korea. The cloud pattern with a treasure motif was used in the covers of a total of 89 books from King Hyojong Gukjangdogam Uigwe (1659) to Sadoseja Garyedogam Uigwe (1744), spanning 86 years. First, to analyze the cloud pattern, it should be broken down into smaller parts to the extent that the different shapes of treasure motifs can be recognized. Secondly, the method of decoding the pattern is as follows: First, check whether the pattern is arranged in one or two directions from the vertex of the cloud's head, and determine the direction of the cloud tail. Then, decode the treasure motif's arrangement starting from the vertex of the cloud's head toward the direction the tail of manja is headed. Record the findings of this decoding process by categorizing them. Thirdly, as a result of the analysis, a total of 28 types of cloud patterns with treasure motifs were identified in 89 books. There were 45 types of treasure motifs used in such patterns. Finally, we have concluded that applying the method of decoding the treasure motif in the cloud pattern to portraits, excavated costumes, and various relics can be useful to establish the chronology of cloud patterns in the late Joseon period. The method suggested in this study is called 'The Reading Method of Chronology in Cloud Pattern with Treasure Motifs' (also 'Jeung-ha Cloud Pattern Reading Method').

Classification of the Family Congridae(Anguilliformes) from Korea (한국산(韓國産) 붕장어과(科)(뱀장어목(目)) 어류(魚類)의 분류(分類))

  • Lee, Chung-Lyul;Park, Mi-Hye
    • Korean Journal of Ichthyology
    • /
    • v.6 no.2
    • /
    • pp.132-159
    • /
    • 1994
  • The taxonomic revision of the family Congridae was made based on the specimens collected from the south-western coasts of the Korea from June 1988 to Oct. 1993. The family Congridae was classified into 8 species belonging to 6 genera. based on the external and internal morphological characters : Anago anago, Ariosoma anagodies, Ariosoma shiroanago shiroanago, Conger myriaster, Conger japonicus, Gnathophis nystromi nystromi, Rhechias retrotincta and Uroconger lepturus. Among the species reported as the congrid eels from Korea until now, four species were transferred into different generic or specific name Conger flavirostris into Ariosoma anagoides ; Astroconger myriaster into Conger myriaster ; Congrina retrotincta into Rhechias retrotincta and Rhynchocymba nystromi into Gnathophis nystromi nystromi. A Korean congrid eel, Ariosoma shiroanago shiroanago, was reported for first time in Korea. Intergeneric characters of the family Congridae were the form of the lateralline scales, the state of the tip of tail, the segmented state of the dorsal and anal fin rays, the existance of the supraoccipital bone and of lateral ethmoid process of the skull, the origin of dorsal fin and the forms of upper labial flange. The interspecific classification was made according to the characters such as the numbers of sensory pores of head part and in front of vent, teeth rows and numbers of upper and lower jaw, the numbers of vertebrae, the body color, the shapes of the head part, the color of intestine, the size of eye, the structure of air bladder and the number of branchiostegal rays. A new key on the taxonomical characteristics to the genera and species of the family Congridae has been estabilished and their distribution in Korea is described.

  • PDF

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

"A Study on Hebrews Clothing in the Old Testament" - Especially on Hair Styles, Headgears, Footwear and Personal Ornaments - (구약성서(舊約聖書)에 나타난 히브리인의 복식(服飾) - 두식(頭飾), 신발 및 장신구(裝身具) 중심(中心)으로 -)

  • Park, Chan-Boo
    • Journal of the Korean Society of Costume
    • /
    • v.10
    • /
    • pp.63-80
    • /
    • 1986
  • The Old Testament cotains mention of the history of creation and clothing in ancient Hebrew. This study dealt with Hebrew dress customs especially aimed at the manners of their hair styles, headgears, footwear and personal ornaments. References are Korean Revised Version, English King James Version and Revised Standard Version. There is little mention of hair styles and headgears in the Old Testament. Some sort of turban was worn by priests, and soldiers protected themselves with helmets, but most Israelitish men went bareheaded except on special occasions and often wear simple headbands. It was more common for women to use headwear of some type-turbans, scarves, and veils concealing the face. The veil was the distinctive female wearing apparel. All females, with the exception of maidservants and women in a low condition of life, wore a veil. It was the custom for women to wear a veil entirely covering their head in the public. Through most of the Old Testament periods long and thick hair was admired on men and women alike. The Hebrews were proud to have thick and abundant long hair, and they gave much attention to the care of their hair. The caring of hair was deeply related to their rituals. Nazirites never took a razor to their hair during his vow-days, but instead let it grow long, as an offering to God. Men would not cut their beards, but allow them to grow long. The Israelites' standard footwear was a pair of simple leather sandals. This was one of the items of clothing not highly prized. In a colloquial saying of the time, a pair of shoes signified something of small value, and to be barefoot except in times of mourning or on holy place, was a sign either of extreme poverty or humiliation, as in the case of war prisoners. Because precious stones were not mined in the Palestine-Syria region, Hebrews imported them from foreign country. They were consumer-to a large degree limited by their very modest standard of living-but not producers. Hebrews liked the precious stones and were motivated to acquire and wear jewels. Besides their use for adornment and as gifts, the precious or semiprecious stones were regarded by Jews of property. The Hebrews were not innovators in the field of decorative arts. The prohibition of the Law against making any "graven image" precluded the development of painting, sculpture, and other forms of representational art. Jewish men did not indulge in extravagances of dress, and there was little ornamentation among them. Men wore a signet ring on their right hand or sometimes suspended by a cord or chain around the neck. The necklaces, when worn by a male, also bore any symbol of his authority. Bracelets were extremely popular with both men and women, men usually preferring to wear them on their upper arms. The girdle was a very useful part of a man's clothing. It was used as a waist belt, or used to fasten a man's sword to his body, or served as a pouch in which to keep money and other things. Men often carried a cane or staff, which would be ornamented at the top. Among the women there was more apt to be ornamentation than among the men. Hebrew women liked to deck themselves with jewels, and ornamentation of the bride were specially luxurious and numerous. They wore rings on their fingers or On toes, ankle rings, earrings, nosering, necklace, bracelets. Their shapes were of cresent, waterdrops, scarab, insect, animal or plant. Sometimes those were used as amulets. They were made of ceramics, gold, silver, bronze, iron, and various precious stones which were mostly imported from Egypt and Sinai peninsular. Hebrews were given many religious regulations by Moses Law on their hair, headgears, sandals and ornamentation. Their clothing were deeply related with their customs especially with their religions and rituals. Hebrew religion was of monotheism and of revealed religion. Their religious leaders, the prophets who was inspired by God might need such many religious regulations to lead the idol oriented people to God through them.

  • PDF

Effects of Exogenous Thyroid Hormone $(T_3)$ on Skeletal Development and Physiological Conditions of Juvenile Black Seabream (Acanthopagrus schlegeli) (감성돔(Acanthopagrus schlegeli) 치어의 골격발달 및 생리적 조건에 미치는 외인성 갑상선호르몬$(T_3)$의 영향)

  • KANG Duk-Young;CHANG Young Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.2
    • /
    • pp.305-312
    • /
    • 1997
  • Juveniles of black seabream, Acanthopagrus schlegeli were fed with the diets containing 0, 10, 20, 50 and 100 ppm of 3,5,3'-triiodo-1-thyronine $(T_3)$ respectively to assess the effect of this hormone on skeletal development and the change of physiological conditions for 50 days. $(T_3)$ treatment lasted for initial 40 days. Fish were fed the prescribed diet by hand to satiation in $2\~4$ times per day. After an initial 40 days period, skeletal development and abnormality were examined, and after a 50 days period, food intake, hepatosomatic index (HSI), thyroid cell height (TCH) and body proximate composition were also examined. Although toed intake was not different among 0, 10 and 20 ppm, the food intake of black seabream fed with the diets containing 50 and 100 ppm of $T_3$was significantly lower than those of 10 ppm. After the initial 40 days of $T_3$ administration, $T_3$ increased the relative growth of operculum, head, caudal fin and pectoral fin to body length, resulting in severe morphological abnormalities at the highest dose. Black seabream treated with 50 and 100 ppm of $T_3$ had abnormal shapes such as lordosis and opercular curl. The HSI parameters were reversely correlation with the dietary concentration of $T_3$. After the initial 40 days of this experiment, atrophy of thyroid gland was observed in fish administered with 50 and 100 ppm of $T_3$. On the 50th day of this experiment, atrophy of thyroid gland was observed only in the group administered with 100 ppm of $T_3$, and no difference was observed on TCH among the rest fours of experimental groups. At the end of the experiment the whore body proximate analyses indicated that there were significant effects of $T_3$ level on moisture, protein, lipid and ash contents.

  • PDF

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture