• Title/Summary/Keyword: head direction

Search Result 530, Processing Time 0.035 seconds

Comparison treatment planning with the measured change the dose of each Junction section according to the error of setup CSI Treatment with Conventional, IMRT, VMAT (Conventional, IMRT, VMAT을 이용한 CSI 치료시, Setup 오차에 따른 각 Junction부의 선량변화측정을 통한 치료계획 비교)

  • Lee, Ho Jin;Jeon, Chang Woo;Ahn, Bum Suk;Yu, Sook Hyeon;Park, So Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • Purpose : Conventional, IMRT, at CSI treatment with VMAT, this study compare the treatment plan with dose changes measured at Junction field according to the error of Setup. Materials and Methods : This study established Conventional, the IMRT, VMAT treatment planning for CSI therapy using the Eclipse 10.0 (Eclipse10.0, Varian, USA) and chose person in Seoul National University Hospital. Verification plan was also created to apply IMRT QA phantom for each treatment plan to the film measurements. At this time, the error of Setup was applied to the 2, 4, 6mm respectively with the head and foot direction. ("+" direction of the head, "-" means that the foot direction.) Using IMRT QA Phantom and EBT2 film, was investigated by placing the error of Setup for each Junction. We check the consistency of the measured Film and plan dose distribution by gamma index (Gamma index, ${\gamma}$). In addition, we compared the error of Setup by the dose distribution, and analyzing the uniformity of the dose distribution within the target by calculating the Homogeneity Index (HI). Results : It was figured out that 90.49%-gamma index we obtained with film is agreement with film scan score and dose distribution of treatment plan. Also, depend on the dose distribution on distance, if we make the error of Setup 2, 4, 6mm in the head direction, it showed that 3.1, 4.5, 8.1 at $^*Diff$(%) of Conventional, 1.1, 3.5, 6.3 at IMRT, and 1.6, 2.5, 5.7 at VMAT. In the same way, if we make the error of Setup 2, 4, 6mm in the foot direction, it showed that -1.6, -2.8, -4.4 at $^*Diff$(%) of Conventional, -0.9, -1.6, -2.9 at IMRT, and -0.5, -2.2, -2.5 at VMAT. Homogeneity Index(HI)s are 1.216 at Conventional, 1.095 at IMRT and 1.069 at VMAT. Discussion and Conclusion : The dose-change depend on the error of Setup at the CSI RT(radiation therapy) using IMRT and VMAT which have advantages, Dose homogeneity and the gradual dose gradients on the Junction part is lower than that of Conventional CSI RT. This a little change of dose means that there is less danger on patients despite of the error of Setup generated at the CSI RT.

Modified External Skeletal Fixation for Craniodorsal Coxofemoral Luxation in 5 Dogs (개의 전배측 고관절 탈구에서 변형된 외골격 고정 적용 5례)

  • Jung, Chang-Su;Lim, Ji-Hey;Byeon, Ye-Eun;Kim, Wan-Hee;Yoon, Jung-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.631-635
    • /
    • 2007
  • Luxation of the hip is the most common luxation seen in small animals. Luxations are classified by the direction in which the femoral head lies in relation to the acetabulum and craniodorsal luxations are the most common type. Recommendations for treatment are based on the presence of preexisting disease, the type and duration of luxation and severity of concurrent injuries. In this study modified external skeletal fixation was used for craniodorsal coxofemoral luxation in 5 dogs. Luxated head Joint was reduced and fixator pins were applied into the greater trochanter, the middle point of iliac body and the lateral surface of sacroiliac joint in a closed fashion. Reduction was successful in 4 of the 5 operated limbs. Complications noted in this study included pin tract drainage, pin loosening and secondary fracture at the pin insertion site.

Improved Momentum Exchange Theory for Incompressible Regenerative Turbomachines (II) - Loss Model and Performance Prediction - (비압축성 재생형 기계에 대한 개선된 운동량 교환 이론 (II) - 손실 모델 및 성능 예측 -)

  • Park Mu Ryong;Chung Myung Kyoon;Yoo Il Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1247-1254
    • /
    • 2004
  • In momentum exchange theory the loss models for the circulatory flow is critically important. But because of lack of loss model on the circulatory flow, analysis model on regenerative turbomachines is not available in the open literature. In the present study circulatory loss is evaluated by combining bend's losses. Through the comparison with the previous experimental data on linear pressure gradient, a combination factor is suggested in terms of the aspect ratio of a channel. Applying this factor to two kinds of regenerative blowers the predicted results are found to be in good agreement with the experimental data of the overall performance and the head distribution along the rotational direction. Especially, the comparison with the head distribution demonstrates the accuracy of hydraulic model and loss model suggested in the present study. And the comparison with the overall performance confirms the validness of physical models as well as loss models suggested in the present study.

Test of Headed Reinforcement in Pullout

  • Park, Dong-Uk;Hong, Sung-Gul;Lee, Chin-Yong
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.102-110
    • /
    • 2002
  • Results of an experimental study on the pullout behavior of the headed reinforcement are presented. A total of 48 pullout tests was performed to evaluate pullout strengths and load-displacement behaviors in pullout of the headed bars. The square steel heads had gross area of 4 $A_{b}$ and thickness of $d_{b}$ The test program consisted of three pullout test groups: Simple and Edge pullout tests using plain concrete slabs, comparison of pullout performances between the standard hooks and the headed reinforcement, and pullout tests of headed reinforcement using reinforced concrete columns. Test variables included concrete strengths ( $f_{c}$' = 27.1MPa, 39.1MPa), reinforcing bar diameters (D16~D29), embedment depths (6 $d_{b}$~12 $d_{b}$), edge conditions, column reinforcement, and single-vs.-multiple bar pullout. Test results revealed that the heads effectively provided the pullout resistances of the deformed bars in tension. The load-displacement behaviors were similar between the 90-degree hooks and the headed reinforcement. When a multiple number of headed bars installed with small head-to-head spacings was pulled out, reinforcement designed to run across the concrete failure surface in a direction parallel to the headed bars helped improve the pullout performances of the headed reinforcement.t.ement.t.

  • PDF

A Case Study on the Failure of Intake and Exhaust Valves for Marine Diesel Engines

  • Kim Jong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.801-807
    • /
    • 2005
  • Any failure of intake and exhaust valves of marine diesel engine must be regarded as serious, and any steps which can be taken to prevent such failure are desirable. The purposes of this study is to investigate and to analyse the failure causes of intake and exhaust valves for marine diesel engine during sea trial after completion of overhauling. In this study, to analyse the failure causes, we have carried out on board inspection, fractography test and discussion based on the specimen and repairing report provided by the ship owner. From the results of above inspection, test and discussion, it has been considered reasonable to conclude that the causes of damaged valves of the ship are as follow ; 1) During operation, the stick or seizure of valve spindle occurred and hence the movement of exhaust valve spindle was to be resisted and subsequently the engine was to be operated under an unappropriated valve timing and the exhaust valve sustained the repeated loads exceeding the fatigue strength of valve material. 2) By the loads above described, the fatigue fracture was initiated at the structural noncontinuous part of exhaust valve spindle, and then the valve head was finally fractured and dropped in the cylinder. 3) The fractured exhaust valve head impacted the intake valve at various direction to be bent or damaged.

Immersive user interfaces for visual telepresence in human-robot interaction (사람과 로봇간 원격작동을 위한 몰입형 사용자 인터페이스)

  • Jang, Su-Hyeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.406-410
    • /
    • 2009
  • As studies on more realistic human-robot interface are being actively carried out, people's interests about telepresence which remotely controls robot and obtains environmental information through video display are increasing. In order to provide natural telepresence services by moving a remote robot, it is required to recognize user's behaviors. The recognition of user movements used in previous telepresence system was difficult and costly to be implemented, limited in its applications to human-robot interaction. In this paper, using the Nintendo's Wii controller getting a lot of attention in these days and infrared LEDs, we propose an immersive user interface that easily recognizes user's position and gaze direction and provides remote video information through HMD.

  • PDF

Vocal Fold Videokymography: New Approach for the Analysis of Vocal Fold Vibratory Pattern

  • Lee, J.S.;Kim, E.J.;Yi, W.J.;Park, K.S.;Sung, M.Y.;Sung, M.H.;Kim, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.313-315
    • /
    • 1997
  • We developed a new analysis technique for the assessment of irregular vibratory movement of vocal folds. Successive frames of pre-recorded video images from videostroboscopy were transferred to computer memory and a vibratory tract of one selected point was described as a waveform by displaying the same lines of all frames along the y-direction. By applying this technique, irregular vibratory patterns of multiple regions, such as asynchronized registration of glottal cycles, could be easily visualized. It would be possible to monitor and analyze the pathologic changes of vocal fold movement by means of this newly developed system.

  • PDF

Study on the Characteristic of Eye Movement for Visual Improvement of the Elderly

  • Yu, Mi;Piao, Yong-Jun;Kim, Yong-Yook;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.202-205
    • /
    • 2005
  • The purpose of this work is to identify the characteristic of eye movement for visual training of the elderly. This investigation is to examine the relationship between the head and the eye motor system for the localization of visual target direction in three-dimensional space. All experiments were performed in a soundproof chamber. Twenty-one red LEDs (Light-Emitting Diode, Brightness: 20cd/$m^2$) arrayed in three lines on a half circle-surrounding panel are used. LEDs are horizontally 30 degree apart and vertically 20 degree apart from each other. The condition of stimulation is random and anti-saccade. Physiological parameter such as EOG (Electro-Oculography) was measured by BIOPAC system. We measure the mean latency time, which is the time from the start of visual stimulation to the response of the human body. The result shows that the mean latency time is short in the case of the condition of anti-saccade, the fixed head and a quarter visual stimulation. This finding can be used in developing programs for various visual improvements for the elderly by analyzing the characteristic of eye movement.

  • PDF

User Interfaces for Visual Telepresence in Human-Robot Interaction Using Wii Controller (WII 컨트롤러를 이용한 사람과 로봇간 원격작동 사용자 인터페이스)

  • Jang, Su-Hyung;Yoon, Jong-Won;Cho, Sung-Bae
    • Journal of the HCI Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • As studies on more realistic human-robot interface are being actively carried out, people's interests about telepresence which remotely controls robot and obtains environmental information through video display are increasing. In order to provide natural telepresence services by moving a remote robot, it is required to recognize user's behaviors. The recognition of user movements used in previous telepresence system was difficult and costly to be implemented, limited in its applications to human-robot interaction. In this paper, using the Nintendo's Wii controller getting a lot of attention in these days and infrared LEDs, we propose an immersive user interface that easily recognizes user's position and gaze direction and provides remote video information through HMD.

  • PDF

Lateral Behavior Characteristics of Short Pile in Sands by Model Tests (모형실험에 의한 사질토 지반에서 단말뚝의 수평거동 특성)

  • Kim, Jin-Bok;Park, Jong-Un;Han, Dae-Hwan;Kwon, Oh-Kyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.366-376
    • /
    • 2008
  • The model tests of short pile with very small pile length/diameter(L/D) were performed in this paper. Varying the pile diameter, length, and the lateral loading point, the lateral resistance and behavior of very short pile were studied in this model tests. The experimental and analytical results are as follows. The lateral ultimate resistance of short pile in sands was the maximum at the point of h/L=0.75, regardless of pile length/diameter(L/D). As the pile diameter is larger, the lateral ultimate resistance of pile with L/D=1 decreases a little and the lateral resistance increases according to the ratio of pile length/diameter. As the lateral loads are acting on the pile, the displacement of pile head is maximum at the pile top of h/L=0, but minimum at the middle point of the pile. And if the loading point is under the middle of pile, the displacement of pile head occurs oposite in the loading direction, but its magnitude is very small.

  • PDF