신경회로망을 이용한 배전선 사고 검출 기법의 개발 (Development of Fault Detection and Classification Method in Distribution Lines)

  • 김광호;최정환;장성일;강용철;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1114-1117
    • /
    • 1998
  • Recent applications of neural networks to power system fault diagnosis have provided positive results and have shown advantages in process speed over conventional approaches. This paper describes the application of neural network to fault detection and classification in distribution lines using the fundamental component, 2-5th harmonics index, even and odd harmonics index, and zero phase current. The Electromagnetic Transients Program (EMTP) is used to obtain fault patterns for the training and testing of neural networks. The proposed fault detection and classification method in distribution lines is obtained by analysing the difference among normal, HIF, ground fault, short circuit fault condition.

  • PDF

누설전류의 제3고조파 분석에 의한 ZnO소자의 열화진단기술 (A Technique of Deterioration Diagnosis for ZnO Element by Analyzing the 3rd order Harmonics- of Leakage Current)

  • 이복희;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1740-1742
    • /
    • 1998
  • This paper describes the technique of deterioration diagnosis for ZnO element. Due to the non-linear resistance of ZnO block, the total leakage current contains harmonics when arrester deteriorated. The most significant harmonics is the 3rd order component. So, it can be used as an indicator of the arrester condition. An iron core, which has a very high relative permeability, is used for increasing detection sensitivity and the 3th order harmonics of leakage current was detected by band-pass circuit. And we have verified the reliability and performance of the sensing device through several laboratory tests.

  • PDF

A Novel Active Anti-islanding Method for Grid-connected Photovoltaic Inverter

  • Jung, Young-Seok;Choi, Jae-Ho;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.64-71
    • /
    • 2007
  • This paper proposes a novel active frequency drift (AFD) method to improve the islanding detection performance with minimum current harmonics. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning the safety hazards and possible damage to other electric equipment, anti-islanding methods have been described. The AFD method that uses chopping fraction (cf) enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD method is inefficient and causes difficulty in designing the appropriate cf value to meet the limit of harmonics. In this paper, the periodic chopping fraction based on a novel AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also better performance of islanding detection compared with the conventional AFD method.

Weighting Method to Identify Interharmonics based on Calculating the Bandwidth in Group-Harmonics

  • Vahedi, Hani;Kiapi, Alireza Alizadeh;Bina, Mohammad Tavakoli;Al-Haddad, Kamal
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.170-176
    • /
    • 2013
  • Power converters produce a vast range of harmonics, subharmonics and interharmonics. Harmonics analyzing tools based on the Fast Fourier Transform (FFT) assume that only harmonics are present and the periodicity intervals are fixed, while these periodicity intervals are variable and long in the presence of interharmonics. Using FFT may lead to invalid and undesired results due to the above mentioned issues. They can also lead to problems such as frequency blending, spectral leakage and the picket-fence effect. In this paper, the group-harmonic weighting (GHW) approach has been presented to identify the interharmonics in a power system. Afterwards, a modified GHW has been introduced to calculate the proper bandwidth for analyzing the various values of interharmonics. Modifying this method leads to more precise results in the FFT of a waveform containing inter harmonics especially in power systems with a fundamental frequency drift or frequency interference. Numerical simulations have been performed to prove the efficiency of the presented algorithm in interharmonics detection and to increase the accuracy of the FFT and the GWH methods.

능동전력필터를 위한 확장된 전류 동기 검출법 (The Expanded Current Synchronous Detection for Active Power Filters)

  • 정영국;김우용;임영철
    • 전력전자학회논문지
    • /
    • 제6권4호
    • /
    • pp.341-347
    • /
    • 2001
  • 전류 동기 검출법은 3상이 불평형된 전원 시스템 하에서도 전원전류를 평형된 정현파로 보상해 줄 뿐 만 아니라 순시전력이론에 비해서 단상에도 적용가능한 이론이다. 그러나 종전의 전류 동기 검출법은 능동전력필터가 고조파 성분과 기본파 무효성분을 독립 제어하는 하이브리드형 능동전력필터 시스템 등에는 적용하기 곤란하다. 따라서 본 연구에서는 불평형 전원 시스템 하에서도 비선형 부하전류를 유효성분, 기본파 무효성분 그리고 왜형성분으로 분해하여 독립제어 가능한 확장된 전류 동기 검출법을 제시하였다. 본 연구에서 제시한 방법의 타당성을 입증하기 위해, 불평형 교류 전원 하에서 평균전력이론, 동기 전류 검출법 그리고 제안된 방법을 실험에 의하여 비교검토하였다.

  • PDF

최소자승법을 이용한 적응형 데이터 윈도우의 거리계전 알고리즘 (Distance Relaying Algorithm Based on An Adaptive Data Window Using Least Square Error Method)

  • 정호성;최상열;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.371-378
    • /
    • 2002
  • This paper presents the rapid and accurate algorithm for fault detection and location estimation in the transmission line. This algorithm uses wavelet transform for fault detection and harmonics elimination and utilizes least square error method for fault impedance estimation. Wavelet transform decomposes fault signals into high frequence component Dl and low frequence component A3. The former is used for fault phase detection and fault types classification and the latter is used for harmonics elimination. After fault detection, an adaptive data window technique using LSE estimates fault impedance. It can find a optimal data window length and estimate fault impedance rapidly, because it changes the length according to the fault disturbance. To prove the performance of the algorithm, the authors test relaying signals obtained from EMTP simulation. Test results show that the proposed algorithm estimates fault location within a half cycle after fault irrelevant to fault types and various fault conditions.

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구 (A Study on the Islanding Detection for Grid Connected Photovoltaic System)

  • 이기제;김민;이진섭;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

개선된 DFT를 이용한 위상 추종방법 (PLL Method Using The Improved Discrete Fourier Transform)

  • 김재형;지용혁;원충연;정용채
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.91-93
    • /
    • 2008
  • In this paper, novel phase angle following algorithm for the single phase grid-connected inverter is proposed. Gird-connected inverter needs phase angle detection for synchronization grid voltage with the inverter output. In case of single phase grid-connected inverter, zero crossing detection and virtual 2-phase PLL using digital all pass filter or digital low pass filter are used conventionally. But these methods have a weakness for harmonics, noises and ripples. The proposed method of PLL achieve DFT(Discrete Fourier Transform) using Goertzel algorithm. It can extract fundamental voltage of grid. As a results, it can obtain phase angle using digital all pass filter without effect of harmonics, noises and ripples. Simulation results are presented to demonstrate the effectiveness of the proposed algorithm.

  • PDF

An Advanced Three-Phase Active Power Filter with Adaptive Neural Network Based Harmonic Current Detection Scheme

  • Rukonuzzaman, M.;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권1호
    • /
    • pp.1-10
    • /
    • 2002
  • An advanced active power filter for the compensation of instantaneous harmonic current components in nonlinear current load is presented in this paper. A novel signal processing technique using an adaptive neural network algorithm is applied for the detection of harmonic components generated by three-phase nonlinear current loads and this method can efficiently determine the instantaneous harmonic components in real time. The control strategy of the switching signals to compensate current harmonics of the three-phase inverter is also discussed and its switching signals are generated with the space voltage vector modulation scheme. The validity of this active filtering processing system to compensate current harmonics is substantiated on the basis of simulation results.