The Expanded Current Synchronous Detection for Active Power Filters

능동전력필터를 위한 확장된 전류 동기 검출법

  • Published : 2001.08.01

Abstract

Harmonics and fundamental reactive current of nonlinear loads in serious unbalanced power condition, are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system. But, the CSD theory is not suitable any more, in case of controlled independently harmonics and reactive component. Therefore, a new algorithm, the expanded current synchronous detection(ECSD) theory for a three phase active power filter based on decomposition of fundamental reactive, distorted components, is proposed in this paper. The proposed ECSD theory is experimented and tested comparison with a few power theories under asymmetrical condition in power system.

전류 동기 검출법은 3상이 불평형된 전원 시스템 하에서도 전원전류를 평형된 정현파로 보상해 줄 뿐 만 아니라 순시전력이론에 비해서 단상에도 적용가능한 이론이다. 그러나 종전의 전류 동기 검출법은 능동전력필터가 고조파 성분과 기본파 무효성분을 독립 제어하는 하이브리드형 능동전력필터 시스템 등에는 적용하기 곤란하다. 따라서 본 연구에서는 불평형 전원 시스템 하에서도 비선형 부하전류를 유효성분, 기본파 무효성분 그리고 왜형성분으로 분해하여 독립제어 가능한 확장된 전류 동기 검출법을 제시하였다. 본 연구에서 제시한 방법의 타당성을 입증하기 위해, 불평형 교류 전원 하에서 평균전력이론, 동기 전류 검출법 그리고 제안된 방법을 실험에 의하여 비교검토하였다.

Keywords

References

  1. IEE Proc. Electro. Power Appl. v.147 no.6 Single-Phase Active Power Filter based on Three-Dimensional Current Coordinates Y. G. Jung;Y. C. Lim;S. H. Yang
  2. IEEE ISIE A New Control method for Obtaining Reference Currents of Shunt Active Power Filters in Unbalanced and Nonsinusoidal Conditions A. Abellan;J. M. benavent
  3. IEEE IAS Operation Strategy of Hybrid Harmonic filter in Demand-Side System Chin. E. Lin
  4. EPE Hybrid Filteration in Conditions of Asymmetric Nonlinear Load Current Pulsation R. Strzelecki