• Title/Summary/Keyword: harmonic compensation

Search Result 315, Processing Time 0.022 seconds

A Study of Control Algorithm For Series Active Power Filter Using Performance Function (성능함수를 이용한 직렬형 능동전력필터의 제어알고리즘에 관한 연구)

  • Ko Soo-Hyun;Kim Jin-Sun;Kim Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.199-202
    • /
    • 2002
  • This paper suggests the control algorithm of a 3-phase 3-wire series active power filters which have harmonic voltage source and harmonic current source This suggested control algorithm can compensate harmonics which are generated by nonlinear load such as diode or thyristor converter and reactive power in 3-phase 3-wire power distribution system This control algorithm extracts a compensation voltage reference from performance function without phase transformation Therefore this control algorithm is simpler than any other conventional control algorithm. 3-phase 3-wire series active power filter and hybrid active power filter is manufactured and experiments are carried out for harmonic voltage source and harmonic current source to verify the effectiveness of presented control algorithm Experimental results are presented in this Paper, as well.

  • PDF

An Enhanced Harmonic Voltage Compensator for General Loads in Stand-alone Distributed Generation Systems

  • Trinh, Quoc-Nam;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1070-1079
    • /
    • 2013
  • This paper develops an enhanced harmonic voltage compensator which is implemented with the aid of two repetitive controllers (RCs) in order to improve the output voltage performance of stand-alone distributed generation (DG) systems. The proposed harmonic voltage compensator is able to maintain the DG output voltage sinusoidal regardless of the use of nonlinear and/or unbalanced loads in the load side. In addition, it can offer good steady-state performance under various types of loads and a very fast dynamic response under load variations to overcome the slow dynamic response issue of the traditional RC. The feasibility of the proposed control strategy is verified through simulations and experiments.

Simple Harmonic Compensation Scheme for a Grid-connected Inverter in Distributed Generation Systems (분산 전원 시스템을 위한 계통연계 인버터의 간단한 고조파 보상 기법)

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.53-54
    • /
    • 2015
  • A new simple and effective scheme to improve power quality for a grid-connected inverter in distributed generation systems under distorted grid voltages will be presented. The proposed scheme is constructed with two controllers to regulate fundamental and harmonic components separately. In order to accomplish the proposed control scheme, the fourth order band pass filter is used to extract harmonic components from distorted gird voltages. Then, the undesired harmonic components are excellently suppressed by proportional decoupling controller. Experimental results are presented to verify the simplicity and effectiveness of proposed scheme.

  • PDF

A Study on the Conceptual Design & Test System of PV-AF System (PV-AF 시스템의 개념설계 및 시제작 시스템에 관한 연구)

  • Park, Young-Gil;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1687-1689
    • /
    • 2005
  • In this paper, novel concept of a photovoltaic(PV) power generation system adding the function of active filter(AF) is proposed. Even PV power generation system can be treated to a harmonics source for the power distribution system, it is necessary that the function of AF system in grid connected PV power generation system. Active Filters intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer, and harmonic damping throughout power distribution system. So, the PV system combined the function of AF system can be usefully applied in power distribution system. Here, the control strategy of PV-AF system is introduced.

  • PDF

A Novel Control Scheme Based on the Synchronous Frame for APF

  • Wang, Yifan;Zheng, Hong;Wang, Ruoyin;Zhu, Wen
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1553-1562
    • /
    • 2017
  • For the purpose of enhancing the performance of the shunt active power filter (APF), this paper presents a novel Fast Weighted Compound Control (FWCC) strategy based on the synchronous frame. In this control strategy, the proposed new repetitive controller can work faster and more stably by reducing the internal model cycle and introducing a damping coefficient. In addition, the harmonic detector can be removed to simplify the structure of the APF owing to the improvements. Furthermore, a proportional-integral (PI) controller is added to work in parallel with the repetitive controller by using a weighted ratio. Then, a convergence speed analysis and design algorithm are given in detail. Simulation and experimental results show that the harmonic distortion is reduced from 2.91% to 1.89%. In addition, the content for each of the characteristic harmonic orders has decreased by more than three times.

Performance improvement of a voltage source active filter (병렬형 전압원 능동필터의 성능개선)

  • Kang, Yu-Ri;Kim, Won-Ho;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.553-555
    • /
    • 1994
  • Various nonlinear loads such as diode rectifiers, and phase controlled converters connected to at source cause harmonic pollutions in ac mains. Recently some filters have been proposed to minimize the potential problems. This study describes a method to improve the performances of a voltage source active filter. Two feedback loops are used in the scheme : one for reactive power compensation and the other for harmonic eliminations.

  • PDF

Shunt Active Filter for Multi-Level Inverters Using DDSRF with State Delay Controller

  • Rajesh, C.R.;Umayal, S.P.
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.863-870
    • /
    • 2018
  • The traditional power control theories for the harmonic reduction methods in multilevel inverters are found to be unreliable under unbalanced load conditions. The unreliability in harmonic mitigation is caused by voltage fluctuations, non-linear loads, the use of power switches, etc. In general, the harmonics are reduced by filters. However, such devices are an expensive way to provide a smooth and fast response to secure power systems during dynamic conditions. Hence, the Decoupled Double Synchronous Reference Frame (DDSRF) theory combined with a State Delay Controller (SDC) is proposed to achieve a harmonic reduction in power systems. The DDSRF produces a sinusoidal harmonic that is the opposite of the load harmonic. Then, it injects this harmonic into power systems, which reduces the effect of harmonics. The SDC is used to reduce the delay between the compensation time for power injection and the generation of a reference signal. The proposed technique has been simulated using MATLAB and its reliability has been verified experimentally under unbalanced conditions.

Level Number Effect on Performance of a Novel Series Active Power Filter Based on Multilevel Inverter

  • Karaarslan, Korhan;Arifoglu, Birol;Beser, Ersoy;Camur, Sabri
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.711-721
    • /
    • 2018
  • This paper presents a single-phase asymmetric half-bridge cascaded multilevel inverter based series active power filter (SAPF) for harmonic voltage compensation. The effect of level number on performance of the proposed SAPF is examined in terms of total harmonic distortion (THD) and system efficiency. Besides, the relationship between the level number and the number of switching device are compared with the other multilevel inverter topologies used in APF applications. The paper is also aimed to demonstrate the capability of the SAPF for compensating harmonic voltages alone, without using a passive power filter (PPF). To obtain the required output voltage, a new switching algorithm is developed. The proposed SAPF with levels of 7, 15 and 31 is used in both simulation and experimental studies and the harmonic voltages of the load connected to the point of common coupling (PCC) is compensated under two different loading conditions. Furthermore, very high system efficiency values such as 98.74% and 96.84% are measured in the experimental studies and all THD values are brought into compliance with the IEEE-519 Standard. As a result, by increasing the level number of the inverter, lower THD values can be obtained even under high harmonic distortion levels while system efficiency almost remains the same.

Design and Control of Grid-connected Photovoltaic system using the state space Modeling (상태공간 모델링을 이용한 계통연계 태양광발전시스템의 설계 및 제어)

  • Hwang, In-Ho;Kim, Si-Kyeong;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.431-433
    • /
    • 1996
  • It is expected that utility interactive small scale dispersed PV system will be widely diffused in the future. This paper discussed the design and control method of single phase PV inverter system with compensation capability of reactive power including harmonic distortion, based on state space modelling. As the results, compensation effects were suggested by simulation and experiment.

  • PDF

A New Scheme for Compensation of Unwanted Components of Instantaneous Load Power

  • Wong, Man-Chung;Han, Ying-Duo;Leong, Heng-San;Sio, Hon-Pan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.888-893
    • /
    • 1998
  • In practice, not only the load current but also the load voltage may contain asymmetric and harmonic components. Instantaneous power using p-q theory is analyzed to have compensation of reactive power, harmonics and asymmetry at the same time. In this paper, the limitation of p-q theory by using only shunt or series active filter is analyzed. A new scheme is proposed to solve the above issues.

  • PDF