• Title/Summary/Keyword: hardness tests

Search Result 716, Processing Time 0.022 seconds

Research on the Electric device for the Noncontacting Hardness Tester (비접촉식 경도 측정용 전기 설비에 관한 연구)

  • 이진락;백기남
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.45-47
    • /
    • 1991
  • In this research, we verify the relations between the mechanical hardness of a strip and the output of Residual Magnetic Flux Detector, which is installed in the end side of #2 CAL. First, we install the strip speed detector and get a hardness signal and a speed signal 2 seconds, and then do signal processing and send an output to a printer every 30 seconds. The system that performs above functions is Magnetic Hardness Data Acquisition & Processing System. We got the relation between output current and hardness for the strip of T3 BP through on-line tests. Seconds, we made a hardness Measurement Simulator and observed the speed characteristics of residual magnetic flux, with using it.

  • PDF

The Studies of Irradiation Hardening of Stainless Steel Reactor Internals under Proton and Xenon Irradiation

  • Xu, Chaoliang;Zhang, Lu;Qian, Wangjie;Mei, Jinna;Liu, Xiangbing
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.758-764
    • /
    • 2016
  • Specimens of stainless steel reactor internals were irradiated with 240 keV protons and 6 MeV Xe ions at room temperature. Nanoindentation constant stiffness measurement tests were carried out to study the hardness variations. An irradiation hardening effect was observed in proton- and Xe-irradiated specimens and more irradiation damage causes a larger hardness increment. The Nix-Gao model was used to extract the bulk-equivalent hardness of irradiation-damaged region and critical indentation depth. A different hardening level under H and Xe irradiation was obtained and the discrepancies of displacement damage rate and ion species may be the probable reasons. It was observed that the hardness of Xe-irradiated specimens saturate at about 2 displacement/atom (dpa), whereas in the case of proton irradiation, the saturation hardness may be more than 7 dpa. This discrepancy may be due to the different damage distributions.

Development of Travelling Cone-Penetrometer (주행형(走行型) Cone-Penetrometer 개발(開發)에 관(關)한 연구(硏究))

  • Lee, K.M.;Song, J.G.;Chang, D.C.;Chung, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.3
    • /
    • pp.1-6
    • /
    • 1987
  • The objective of this study is to develop a soil hardness tester which can estimate tillage resistance with tae travelling cone-penetrometer. For the study, a series of tests was performed using the cone penetrating in the horizontal direction. Based on the tests above, soil hardness was represented by travelling cone-index vs depth of cone penetration, travelling speed and moisture contents of the soil Resistance characteristics obtained from the experiments were compared with those by a vertical cone-penetrometer and the Yamanaka's soil hardness tester. Following conclusions were made from the study. 1. 8 to 9 peaks per one meter were detected in the resistance curve of cone penetration regardless of the travelling speed of cone-penetrometer when it penetrated the soil in the horizontal direction. This phenomenon seemed to be a similar one noticed in shearing pitch of plowing. 2. Cone index increased as travelling speed increased from 0.08m/sec to 0.5m/sec. 3. Linear relationship was found between the cone indices measured by the travelling coe-penetrometer and Yamanaka's hardness tester. 4. Increasing rate of the cone indices measured by vertical cone-penetrometer decreased as the depth of soil increased while the cone indices by the travelling cone-pentrometer increased linearly.

  • PDF

Mechanical Properties of Forged Nimonic 80A Superalloy Fabricated by Vacuum Spray Casting (진공분무주조법에 의해 제조한 Nimonic 80A 초내열합금 단조재의 기계적 특성)

  • Lee, Yun-Soo;Hyun, Soong-Keun;Jung, Dae-Hyun;Byun, Joong-Sig
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.4
    • /
    • pp.263-270
    • /
    • 2012
  • This study investigates the effect of heat treatment on the mechanical properties of a forged Ni-based superalloy called Nimonic 80A. Nimonic 80A ingot samples were fabricated by vacuum spray casting to achieve a fine and homogenized microstructure. The ingot samples were subsequently hot-forged with the diameter of 220 mm at 1373 K. From the center to the surface of the forged Nimonic 80A, its average grain size decreased and its micro-Vickers hardness increased slightly. Solution treatment was carried out at 1353 K with 8 hours of air cooling followed by aging treatment, which was carried out in the range of 873-1073 K with various times from 0.5 to 256 hours. To set the optimum aging conditions, micro-Vickers hardness tests were performed. The maximum hardness value of 388.0 Hv was obtained by aging at 973 K for 32 hours. Also, tensile tests were performed for optimum aging conditions at room temperature and 873 K. The results can be used effectively to perform reasonable heat treatment of Nimonic 80A superalloy.

Corrosion and Sliding Properties of the Nickel-Based Alloys for the Valve Seats Application

  • Honda, Tadashi
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.92-98
    • /
    • 2008
  • This paper describes the experiments of the corrosion and the sliding tests of the nickel-based alloys for the gate valve seating materials used at high pressure and temperature. The general corrosion rates and IGC susceptibility are tested in pressurized water at 533 K and 575 K and in Strauss test solution. The sliding tests have been done in pressurized water at 293 k, 473 K and 573 k. The alloys containing above 10% chromium may have the anti-corrosion properties that could be applied to the valve seats for the power plants. The good sliding performance and the good pressure tightness are obtained when the disc specimens that have hardness 500 to 600 Hv combined with the seat specimens that have hardness 250 to 410 Hv containing about 40 percent of iron. The large size gate valves sliding tests have certified the test results. The anti-wear properties of the seat alloy and the anti-IGC susceptibility of the disc alloy could be improved by the addition of silicon and niobium, respectively.

Use of Unbonded Caps in Determination of Compressive Strength of Hardened Concrete Cylinders (콘크리트 원주형 공시체의 압축강도 시험을 위한 Unbonded Cap의 사용)

  • 심재원;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.161-166
    • /
    • 2000
  • To save efforts for capping in the compressive strength tests of concrete, unbonded capping system has been standardized by ASTM C 1231 and AS 1012.9, respectively. These standards, however, do not sufficiently give a full detail of accessories such as steel retaining cap and rubber pad, especially hardness of rubber. Hence, without testing for sizes of steel retaining cap and rubber pad, tests for the quality control of rubber pads were conducted in detail according to Japanese studies. Based on tests, the range of hardness for rubber pad by the compressive strength(200~ 400kgf/$\textrm{cm}^2$) of concrete has been proposed and the guideline of reuses of a rubber pad is described.

  • PDF

Effect of Third Elements on the Microstructures and Mechanical Properties of Ti-Al Intermetallic Compounds (Ti-Al 금속간화합물의 미세조직 및 기계적 성질에 미치는 제3원소의 영향)

  • Choi, Chang-Woo;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • v.12 no.2
    • /
    • pp.139-148
    • /
    • 1992
  • The mechanical properties of Ti-Al intermetallic compounds which contain Mn, Zr, or Cr as the third element have been evaluated by means of hardness and compression tests. Microstructures have also been examined using an optical microscope. The cast structures of Ti-Al alloys are coarsened and the lamellar volume fraction is increased by the additions of Mn or V, but the cast structures are refined by the addition of Zr. Hardness tests of room temperature and compression tests at $600^{\circ}C$ showed that the mechanical properties of Ti-Al alloys were mainly dependent on the volume fraction of the ${\alpha}_2$ phase, grain size and solid solution hardening. However according to the compression test at $1000^{\circ}C$, the yield strength of Ti-Al alloys decreased with an increase in Mn or Cr content, but increased with an increase in the Zr content.

  • PDF

CHARACTERISTICS OF PLATED GOLD LAYER ON ANSI 304 STAINLESS STEEL ACCORDING TO THE VARIATION OF PRETREATMENTS AND ELECTROLYSIS CONDITIONS

  • Lee, Dong-hun;Lee, Jae-Bong
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.224-234
    • /
    • 1999
  • An attempt was made to characterize the relationship between pretreatment processes, electrolysis conditions and behaviors of the plated gold layer. In order to investigate the effect of pretreatment processes on plating, rest potential measurements of various pretreated stainless steels and a.c.-impedance spectroscopy tests were carried out in the strike plating solution. Characteristics of plated gold layers and adhesions between plated gold layers and stainless steel substrates were examined by scratching tests and micro-Vickers hardness tests. The result shows that the strike plating enhanced the adhesion of interface, the cathodic electro-activation pretreatment process improving both corrosion resistance and adhesion strength. The preferred orientations of plated gold layers were examined by the X-ray diffraction technique. As the current density increases, [111] preferred orientation of plated gold layers was found to become well developed.

  • PDF

Mechanical performance of additively manufactured austenitic 316L stainless steel

  • Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.244-254
    • /
    • 2022
  • For tensile tests, Vickers hardness tests and microstructure tests, plate-type and box-type specimens of austenitic 316L stainless steels were produced by a conventional machining (CM) process as well as two additive manufacturing processes such as direct metal laser sintering (DMLS) and direct metal tooling (DMT). The specimens were irradiated up to a fast neutron fluence of 3.3 × 109 n/cm2 at a neutron irradiation facility. Mechanical performance of the unirradiated and irradiated specimens were investigated at room temperature and 300 ℃, respectively. The tensile strengths of the DMLS, DMT and CM 316L specimens are in descending order but the elongations are in reverse order, regardless of irradiation and temperature. The ratio of Vickers hardness to ultimate tensile strength was derived to be between 3.21 and 4.01. The additive manufacturing processes exhibit suitable mechanical performance, comparing the tensile strengths and elongations of the conventional machining process.

Correction of the hardness measurement for pile-up materials with a nano indentation machine (파일-업 재료에 대한 나노 압입 시험기의 경도 측정값 교정)

  • Park, Moon Shik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.98-106
    • /
    • 2016
  • Measurements of the elastic modulus and hardness using a nano indentation machine rely on the equation for the fitted contact area, which is valid for only sink-in materials. For most soft engineering materials that involve pile-up behavior rather than sink-in, the contact area equation underestimates the contact area and thus overestimates the elastic modulus and hardness. This study proposes a correction method to amend erroneous hardness measurements in pile-up situations. The method is a supplemental derivation to the original hardness measurement with the known value of the elastic modulus. The method was examined for soft engineering metals, Al 6061 T6 and C 12200, via tensile tests, nano indentation tests, impression observations, and finite element analysis. The proposed technique shows reasonable agreement with the analytical results accounting for strain gradient plasticity from a previous study.