• 제목/요약/키워드: hardened concrete

검색결과 562건 처리시간 0.021초

시멘트경화체의 반투과성에 의한 수분이동에 미치는 용액농도와 환경온도의 영향 (Effect of Concentration of Solution and Temperature on Water Flux by Semi-Permeability of Hardened Cement Paste)

  • 배기선;오상근;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.131-136
    • /
    • 1997
  • It is well known that concrete is typical porous material. We pay attention to Hansen's idea that concrete may be expected to act as semi-permeable membrane, and report the effect of concentration of solution and temperature on water flux in forward osmosis. In order to measuring volume of water flux from distilled water to solution of sodium chloride through hardened cement paste, specially designed apparatus was constructed, and the following result were obtained: (1) hardened cement paste acts as semi-permeable membrane, consequently, water flux in forward osmosis may occur. (2) Rate of water flux is proportion to concentration of dilute solution, and this suggests hardened cement paste is agreeable to the theory of membrane. (3) Effect of temperature on water flux is agreeable to Arrehenius equation and is great.

  • PDF

Utilization of Waste Glass Micro-particles in Producing Self-Consolidating Concrete Mixtures

  • Sharifi, Yasser;Afshoon, Iman;Firoozjaei, Zeinab;Momeni, Amin
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권3호
    • /
    • pp.337-353
    • /
    • 2016
  • The successful completion of the present research would be achieved using ground waste glass (GWG) microparticles in self-consolidating concrete (SCC). Here, the influences of GWG microparticles as cementing material on mechanical and durability response properties of SCC are investigated. The aim of this study is to investigate the hardened mechanical properties, percentage of water absorption, free drying shrinkage, unit weight and Alkali Silica Reaction (ASR) of binary blended concrete with partial replacement of cement by 5, 10, 15, 20, 25 and 30 wt% of GWG microparticles. Besides, slump flow, V-funnel, L-box, J-ring, GTM screen stability, visual stability index (VSI), setting time and air content tests were also performed as workability of fresh concrete indicators. The results show that the workability of fresh concrete was increased by increasing the content of GWG microparticles. The results showed that using GWG microparticles up to maximum replacement of 15 % produces concrete with improved hardened strengths. From the results, when the amount of GWG increased there was a gradual decrease in ASR expansion. Results showed that it is possible to successfully produce SCC with GWG as cementing material in terms of workability, durability and hardened properties.

유동화 콘크리트의 시공성 향상 및 강도특성에 관한 기초적 연구(II) (제2보, 경화콘크리트의 강도 특성을 중심으로) (A Fundamental Study on the Workability Improvement and Strength Properties of Superplasticized Concrete(II) (Part 2, In the Case of Strength Properties of Hardened Concrete))

  • 김무한;권영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1989년도 가을 학술발표회 논문집
    • /
    • pp.21-24
    • /
    • 1989
  • The effect of superplasticizing agents on the mechanical properties in hardened concrete have been analyzed and investigated under various mix proportions of water cement ratio of 0.40, 0.50, 0.60 and 0.70, Superplasticizing agents of NL-4000, and Rheobuild-716, and addition rate of sp. agents of 0.0, 0.5, 1.0, 1.5 and 2.0 in the practical range. It is the aim of this study to provide the fundamental data on the compressive strength, dynamic and static modulus of elasticity, stress and strain curve of hardened concrete comparing with base concrete and conventional concrete for the practical use and research data accumulation of superplasticized concrete in the side of development of concrete construction technology and management.

  • PDF

XRF를 활용한 경화 콘크리트의 배합비 역추척에 관한 실험적 연구 (The Experimental Study on the Reanalysis of Mixing Proportion for Hardened Concrete Using X-ray Fluorescence)

  • 이준구;박광수;이응찬;김한중;김명원;박미현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.791-794
    • /
    • 1999
  • Exact estimation of cement content in a hardened concrete can provide useful data to evaluate the quality and strength of the concrete and might be used to inspect the quality of precast concrete secondary products. Observation obtained in this research included : (1) the volume of coarse aggregate in the hardened concrete measured by the area comparison method has a high accuracy ; (2) the cement content in the mortar and the X-ray intensity of Ca-K$\alpha$ have a correlation factor of 0.96 ; (3) the cement content in the ready mixed concrete was estimated with high accuracy such as correlation factor of 0.99 and standard deviation of 0.64.

  • PDF

화상분석기를 이용한 경화콘크리트의 기포분포분석에 관한 기초적 연구 (Image Analysis of an Air-Void System in hardened concrete)

  • 김기철;정재동
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.313-318
    • /
    • 1997
  • Air voids existed in hardened concrete have an important influence on concrete deterioration such as carbonation, freezing and thawing, and corrosion of embedded steel in concrete. Therefore it is very significant to investigate the pore structure of system (size, number and continuity of air voids) to solve the reason caused concrete deterioration. The purpose of this study is to develop th standard method of measuring air voids which affect properties in hardened concrete using image analyzing system. This paper presents the settlement of rapid and exact experimental method which extracts fine bubbles, calculates the number of air voids, and determines air-voids distributions using image analyzing system with computer.

  • PDF

신ㆍ구 콘크리트 접착제의 시공조건에 따른 성능 (Performance of Adhesives for Bonding Fresh Concrete to Hardened Concrete under Application Conditions)

  • 이찬영;심재원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 2002
  • In vertical construction joint, adhesives such as epoxy, acrylic, latex, etc. have been usually used for bonding fresh concrete to hardened concrete. In this study, performance of adhesives under various application conditions was investigated through tests for slant shear and flexural strength. From the results of the tests, it is found that superior bonding performance can be obtained under good surface preparation without adhesive when high strength concrete is used.

  • PDF

폴리에틸렌 튜브를 혼입한 경량 시멘트 경화체의 기초물성 평가 (An Evaluation on the Properties of the Hardened Lightweight Cement Using the Polyethylene Tube)

  • 김세영;전봉민;김효열;오상균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.57-60
    • /
    • 2006
  • This study proposes the physical properties of the hardened lightweight cement using the polyethylene tube and to make the fundamental data regarding a new lightweight concrete development. The aerated concrete is displaying various effects such as lightweight, insulation characteristic and it is coming to be widely applied the slab layer of apartment as an insulating material but currently the aerated concrete has many problems. Therefore, demonstrating similar property of former aerated concrete and improving the defects, developing new hardened cement is needed. In this study, we predict adopting possibility of hollow core polyethylene tube, as a material to make cement hardening containing a lot of void. So we changed the mixing ratio, a diameter and length of the polyethylene tube and improved the compressive strength and unit capacity weight of the lightweight cement hardening body. From the test results, we judge that the aerated concrete is a developmental possibility.

  • PDF

이미지 분석에 의한 콘크리트의 공극 분포 및 공기량 분석 (Air Contents & Size Distribution of Air Voids in Concrete Using Image Analysis)

  • 권혁찬;정원경;윤경구
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.157-164
    • /
    • 2004
  • Air voids in hardened concrete have an important influence on concrete durability such as resistance of freezing and thawing, permeability and surface scaling resistance. Linear traverse method and point count method in ASTM standard method have been widely used to estimate the air void system in hardened concrete. However, these methods are not used at present time, because they are is exhausted much time and effort. In previous study, air voids system of concrete was estimated by spacing factor. The purpose of this study organizes image analysis method by analyzing air contents, air voids distributions by diameters, air voids system as well as spacing factors after hardened concrete. The experimental variables institute of depth of specimen(top, middle, bottom), air contents(AE contents 0, 0.01, 0.03%).

  • PDF

시멘트 경화체의 반투과성에 따른 삼투압의 발생에 관한 검토 (Osmotic Pressure Induced by Semi-Permeability of Hardened Cement Paste and Cement Mortar)

  • 배기선;김용로;박선규;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.160-165
    • /
    • 1999
  • Osmotic pressure induced by semi-permeability of hardened cement pasts and cement mortar was studied, which was considered to be a cause of failure such as separation and blistering of floor coatings or wall coatings from the concrete substrate. The specimens with a water cement ratio of 45, 60 and 75% were installed between the solution of sodium chloride and distilled water. First, we measured water flux from distilled water to sodium chloride and the ion flux of Na+ and Cl- through the specimens. Then, we measured osmotic pressure induced by semi-permeability of the specimens using an apparatus which was specially developed for this study. It was made clear that hardened cement paste and cement mortar have properties of semipermeability, and the osmotic pressure is closely related to their water cement ratio. Finally, we calculated the osmotic pressure according to Staverman's equation, which was obtained for organic membranes, and tried to explain quantitatively the observed pressure.

  • PDF

재생골재 콘크리트 구조체 적용성에 관한 실험적 연구(제2보, 경화 콘크리트의 성상을 중심으로) (An Experimental Study on The Application of Construction of Recycled Aggregate Concrete (part2, in the hardened concrete))

  • 김진만;류광우;남상일;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.12-15
    • /
    • 1993
  • Critical shortage of natural aggregate for production of concrete is developing in many urban area. At the same time increasing quantities of demolished concrete form deteriorated and obsolete structures are generated as a waste material in the same areas. The reuse of a waste concrete may settle the problems of environmental pollution and shortage of adquate aggregate, Therefore, this study is to reuse a waste concrete as aggregate for concrete, It is the purpose of this present study to investigate and analyze how the addition rates of superplasticizer and curing condition affect the properties of fresh and hardened recycled aggregate concrete comparing with those of ordinary concrete and crushed stone concrete.

  • PDF