• 제목/요약/키워드: hard power

검색결과 849건 처리시간 0.031초

원전 DCS용 제어통신망 설계 (A Design of Control Network for DCS in Nuclear Power Plant)

  • 이재민;박태림;문홍주;권욱현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(1)
    • /
    • pp.85-88
    • /
    • 2000
  • Distributed Control System(DCS) is one of the best solutions to implement control systems because it provides continuous observation of control process and execution of commands to induce proper operations. In this paper, a design of control network for DCS in nuclear power plant is proposed. The proposed control network on DCS has a simple architecture and deterministic property. Thus, the proposed control network offers hard real-time periodic service. It also has redundant media for the fault-tolerance. As a result, high safety and reliability required in nuclear power plant are guaranteed.

  • PDF

Comparison of Active-Clamp and ZVT Techniques Applied to Tapped-Inductor DC-DC Converter with Low Voltage and Bigh Current

  • Abe, Seiya;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.199-205
    • /
    • 2002
  • This paper compares three kinds of soft-switching circuits from viewpoints of surge suppression, load characteristic, and power efficiency for a tapped-inductor buck converter with low voltage and high current. As a result, these soft-switching techniques have achieved much higher efficiency of 80 % when compared with a hard-switching buck converter for the output condition of 1V and 20A.

저전력과 입출력 성능이 향상된 n-블록 선반입 기반의 하이브리드 하드디스크 입출력 시스템 설계 및 구현 (Design and Implementation of Hybrid Hard Disk I/O System based on n-Block Prefetching for Low Power Consumption and High I/O Performance)

  • 양준식;고영욱;이찬근;김덕환
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제36권6호
    • /
    • pp.451-462
    • /
    • 2009
  • 최근에 하드 디스크의 낮은 입출력 처리 성능을 개선하는 연구가 활발하게 진행 중이다. 하드웨어 연구는 좋은 성과를 보이고 있지만 시스템의 입출력 성능향상을 지원해야 할 시스템 소프트웨어 기술 발전이 미진하여 하드웨어 성능을 최대로 발휘하지 못하고 있는 상황이다. 본 논문에서는 n-블록을 플래시 메모리로 선반입하는 새로운 방법을 제안한다. 제안한 방법은 세 단계로 구성된다: (1) 블록 단위 읽기 요청의 패턴을 분석하여 n-블록단위로 플래시 메모리에 선반입한다; (2) 입출력 요청 시에 그 블록의 위치를 판단하여 입출력 서비스를 제공한다; (3) 블록 교체 정책에 따라 n-블록을 교체한다. 이 방법을 통해 하드디스크의 대기시간을 줄이고 전력 사용을 최적화 할 수 있다. 실험을 통해 제안한 동적 n-블록 방법이 기존의 AMP(Adaptive multistream prefetching) 방법과 비교하여 9.05%의 평균응답시간을 개선하고 평균전력소모를 11.11% 감소시킴을 확인하였다.

IPTV 셋톱박스 환경에서 스트리밍 데이터 재생을 위한 전력 소모 감소 기법 (Low Power Consumption Technology for Streaming Data Playback in the IPTV Set-top Box)

  • 고영욱;양준식;김덕환
    • 전자공학회논문지CI
    • /
    • 제47권1호
    • /
    • pp.30-40
    • /
    • 2010
  • IPTV 셋톱박스에서 가장 많이 사용하는 저장장치인 하드디스크는 가격에 비해 저장용량이 크고 입출력 속도가 빠르지만 스핀들 모터의 기계적 동작으로 인해 전력 소모가 많다는 단점이 있다. 셋톱박스에서 스트리밍 데이터를 재생하기 위하여 하드디스크의 스핀들 모터는 최대 전력을 사용하는 활성모드를 계속 유지해야 한다. 본 논문에서는 스트리밍 데이터 재생 시 전력 소모를 감소시키는 오프셋-버퍼링(Offset-Buffering)과 다중모드 스핀-다운(Multi Mode Spin-Down) 기법을 제안한다. 오프셋-버퍼링은 사용자의 시청 패턴을 분석하고 분석된 결과를 통해 버퍼링을 하므로 스핀들 모터의 모드를 대기모드로 길게 유지할 수 있다. 또한 오프셋 버퍼의 크기에 따라 다양한 모드로 스핀-다운을 하여 전력 소모를 줄일 수 있다. 실험 결과 본 논문에서 제안한 오프셋-버퍼링과 다중모드 스핀-다운은 기존의 풀-버퍼링(Full-Buffering)보다 28.3% 전력 소모량을 감소시켰으며, 스핀-업 횟수를 12.5% 줄였다.

Improving the Overall Efficiency for DC/DC Converter with LoV-HiC System

  • Han, Dong-Hwa;Lee, Young-Jin;Kwon, Wan-Sung;Bou-Rabee, Mohammed A.;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.418-428
    • /
    • 2012
  • It is very important to improve the overall efficiency of systems with a source of power that has low-voltage high-current terminal characteristics such as fuel cells. A resonant converter is required for high efficiency systems. However, the peak value of the switches current is large in a resonant converter. This peak current requires a large number of switches and results in system failures. In this paper, an analysis and experiments of a resonant isolation push-pull converter are performed. A switching loss analysis is performed in order to compare losses between a resonant push pull converter and a hard switching push-pull converter. Specially, the conduction loss is studied based on the ratio between the resonant frequency and the switching frequency. In addition, a method for improving the efficiency is implemented with conventional HF insolation converters.

IMPLEMENTATION OF DIGITAL POWER METER USING TMS320C5X

  • Ku, Bon-Hyouk;Chok, Myung-Ryul
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.575-580
    • /
    • 1998
  • A power meter is an instrument for measuring in watts the power flowing in a electric equipment. Since the value which a conventional power meter measures is analog, the power meter is hard to determine a phase difference between the voltage and current for a inductive load. The phase difference causes a loss of electric power and a increase of power-line load. In this paper, we propose a digital power meter using TI's DSP(Digital Singnal Processor) TMS320C5x, which is employed to calculate the phase difference and more accurate power consumption.

  • PDF

넓은 영전압 스위칭 범위를 갖는 대화면 PDP용 유지 전원단을 위한 고효율 전력 변환 회로 (A High Efficiency Power Conversion Circuit with Wide ZVS Range for Sustaining Power Module of Large Size PDP)

  • 박경화;이우진;윤명중;문건우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.279-282
    • /
    • 2005
  • Recently, due to the launching of digital broadcasting service, a demand of PDP TV with large screen size is sharply rising. PDP power module is mainly divided into power factor correction (PFC) stage and sustaining power stage. Especially, sustaining power module has pulsating load characteristics. So, the hard switching at light load condition causes low efficiency and thermal problem. Therefore, a new power conversion circuit for sustaining power module of 60' PDP is proposed whose ZVS is obtained by additional ZVS tank. This paper presents properties of the proposed converter through mode analysis, numerical analysis. And a 900w prototype for sustaining power module of 60' PDP is produced to verify the analytic results. As an experimental results, ZVS is achieved from full load to 10% load variation and more than 92% of high efficiency is obtained at 10% load condition.

  • PDF

하이브리드 하드디스크에서 AHP를 적용한 블록 교체 기법 (A Block Replacement Scheme using Analytic Hierarchy Process in Hybrid HDD)

  • 김정원
    • 한국산업정보학회논문지
    • /
    • 제20권5호
    • /
    • pp.45-52
    • /
    • 2015
  • 하이브리드 하드디스크는 저전력이면서 마그네틱 하드디스크에 비해 읽기 성능이 우수하다. 이 디스크의 플래시메모리에는 지역성이 높은 블록이 저장되므로 효율적인 블록 교체 기법이 필요하다. 블록 교체에는 크기, 지역성, 빈도 등 다양한 요인에 의해 결정되므로 일종의 다중 기준 결정 모델로 정의될 수 있다. 이 문제를 해결하기 위해 본 연구는 AHP (Analytic Hierarchy Process) 모델을 적용하여 효율적인 블록 교체 기법을 제시한다. 실험의 효율성을 검증하기 위하여 철저한 시뮬레이션을 수행한 결과 일반응용 프로그램의 응답성뿐만 아니라 부트 시간이 단축됨을 확인하였다.

Series Resonant ZCS- PFM DC-DC Converter using High Frequency Transformer Parasitic Inductive Components and Lossless Inductive Snubber for High Power Microwave Generator

  • Kwon, Soon-Kurl;Saha, Bishwajit;Mun, Sang-Pil;Nishimura, Kazunori;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.18-25
    • /
    • 2009
  • Conventional series-resonant pulse frequency modulation controlled DC-DC high power converters with a high-frequency transformer link which is designed for driving the high power microwave generator has the problem of hard switching commutation at turn-on and turn-off of active power switching devices. This problem is due to the influence of the magnetizing current of the high-frequency transformer. This paper presents a novel prototype for a high-frequency transformer using parasitic parameters with a lossless inductive snubber and a series resonant capacitor assisted series-resonant zero current switching pulse frequency modulated DC-DC power converter, which is designed using a high power magnetron for microwave ovens. In order to implement a complete and efficient soft switching commutation, the performance of the new converter topology is practically confirmed and evaluated in the prototype of a power microwave generator.

Full-bridge Converter의 새로운 ZVS 스위칭 기법 (Novel ZVS Switching Method of Full-bridge Converter)

  • 김승룡;선한걸;한만승;박성준
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.477-483
    • /
    • 2011
  • 일반적인 DC/DC 전력변환기의 스위칭 방식은 하드 스위칭 방식과 공진을 이용한 소프트 스위칭 방식으로 분류할 수 있으며, 하드 스위칭 방식은 스위치의 턴 온/오프시 스위칭 소자에 생기는 전력손실이 커서 효율 면에서 불리하며, 공진형 소프트 스위칭 방식은 별도의 리액터와 커패시터를 추가함으로서 시스템의 사이즈와 비용이 증가하는 단점이 있다. 본 논문에서는 이러한 단점을 극복하기 위해 새로운 스위칭 방식의 소프트 스위칭 방식의 Full-bridge 전력변환기의 구조를 제안하였으며, 제안된 소프트 스위칭 방식은 앞단의 벅 컨버터의 다이오드 전류시 영전압이 되는 구간에서 Full-Bridge 컨버터의 스위치를 교변 함으로써 리액터와 커패시터의 추가없이 소프트 스위칭을 이루어냄으로서 시스템의 효율과 신뢰성을 향상시킨다. 또한 제안된 절연형 소프트 Full-bridge DC/DC 컨버터의 타당성을 검증하기 위해 Psim을 이용한 시뮬레이션과 500[W]급 DC/DC 컨버터를 제작하여 DC/DC 컨버터의 효율이 우수함을 확인하였다.