• Title/Summary/Keyword: hard power

Search Result 850, Processing Time 0.039 seconds

Robust Transceiver Designs in Multiuser MISO Broadcasting with Simultaneous Wireless Information and Power Transmission

  • Zhu, Zhengyu;Wang, Zhongyong;Lee, Kyoung-Jae;Chu, Zheng;Lee, Inkyu
    • Journal of Communications and Networks
    • /
    • v.18 no.2
    • /
    • pp.173-181
    • /
    • 2016
  • In this paper, we address a new robust optimization problem in a multiuser multiple-input single-output broadcasting system with simultaneous wireless information and power transmission, where a multi-antenna base station (BS) sends energy and information simultaneously to multiple users equipped with a single antenna. Assuming that perfect channel-state information (CSI) for all channels is not available at the BS, the uncertainty of the CSI is modeled by an Euclidean ball-shaped uncertainty set. To optimally design transmit beamforming weights and receive power splitting, an average total transmit power minimization problem is investigated subject to the individual harvested power constraint and the received signal-to-interference-plus-noise ratio constraint at each user. Due to the channel uncertainty, the original problem becomes a homogeneous quadratically constrained quadratic problem, which is NP-hard. The original design problem is reformulated to a relaxed semidefinite program, and then two different approaches based on convex programming are proposed, which can be solved efficiently by the interior point algorithm. Numerical results are provided to validate the robustness of the proposed algorithms.

Transmission Network Expansion Planning for the Penetration of Renewable Energy Sources - Determining an Optimal Installed Capacity of Renewable Energy Sources

  • Kim, Sung-Yul;Shin, Je-Seok;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1163-1170
    • /
    • 2014
  • Due to global environmental regulations and policies with rapid advancement of renewable energy technologies, the development type of renewable energy sources (RES) in power systems is expanding from small-scale distributed generation to large-scale grid-connected systems. In the near future, it is expected that RES achieves grid parity which means the equilibrium point where the power cost of RES is equal to the power costs of conventional generators. However, although RES would achieve the grid parity, the cost related with development of large-scale RES is still a big burden. Furthermore, it is hard to determine a suitable capacity of RES because of their output characteristics affected by locations and weather effects. Therefore, to determine an optimal capacity for RES becomes an important decision-making problem. This study proposes a method for determining an optimal installed capacity of RES from the business viewpoint of an independent power plant (IPP). In order to verify the proposed method, we have performed case studies on real power system in Incheon and Shiheung areas, South Korea.

On Dynamic Voltage Scale based Protocol for Low Power Underwater Secure Communication on Sensor Network (센서 네트워크 상에서의 저전력 보안 수중 통신을 위한 동작 전압 스케일 기반 암호화에 대한 연구)

  • Seo, Hwa-Jeong;Kim, Ho-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.586-594
    • /
    • 2014
  • Maximizing the operating time by reducing the power consumption is important factor to operate sensor network under water networks. For efficient power consumption, dynamic voltage scaling method is available. This method operates low frequency when there is no workload. In case of abundant workload, high frequency operation completes hard work within short time, reducing power consumption. For this reason, complex cryptography should be computed in high frequency. In this paper, we apply dynamic voltage scaling method to cryptography and show performance evaluation. With this result, we can reduce power consumption for cryptography in under water communication.

Quadrant Analysis in Correlation between Mechanical and Electrical Properties of Low-Temperature Conductive Film Bonded Crystalline Silicon Solar Cells

  • Baek, Su-Wung;Choi, Kwang-Il;Lee, Woo-Hyoung;Lee, Suk-Ho;Cheon, Chan-Hyuk;Hong, Seung-Min;Lee, Kil-Song;Shin, Hyun-Woo;Yan, Yeon-Won;Lim, Cheolhyun
    • Current Photovoltaic Research
    • /
    • v.3 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • In this study, we analyzed the correlation between mechanical and electrical properties of low-temperature conductive film (LT-CF) bonded silicon solar cells by a quadrant analysis (horizontal axis (peeling strength), vertical axis (power loss)). We found that a series of points with various bonding parameters such as bonding temperature, pressure and time were distributed in the different three regimes; weak regime (Q2: weak bonding strength and high power loss), moderate regime (Q4 : strong bonding strength and low power loss) and hard regime (Q3 : weak bonding strength and low power loss). Using this analogous technique, it was possible to fabricate the LT-CF bonded silicon solar cells with the various conditions displayed in Q3 of the quadrant plots, possessing the peeling strength of ~ 1N/mm and power loss of 2~3%.

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

Soft Switching Single Stage AC-DC Full Bridge Boost Converter Using Non-Dissipative Snubber (무손실 스너버 적용 소프트 스위칭 Single Stage AC-DC Full Bridge Boost 컨버터)

  • 김은수;조기연;김윤호;조용현;박경수;안호균;박순구
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.377-383
    • /
    • 1999
  • A new soft switching single stage AC-DC full bridge boost converter with unit input power factor and isolated output i is presented in this paper. Due to the use of a non-dissipative snubber on the primary side, a single stage high-power f factor isolated full bridge boost converter has a significant reduction of switching losses in the main switching devices. The non-dissipative snubber adopted in this study consists of a snubber capacitor Cr, a snubber inductor Cr, a fast r recovery snubber diode Dr' and a commutation diode Dp. This paper presents the complete operating principles, t theoretical analysis and experimental results.

  • PDF

Soft-Switching Boost Chopper Type DC-DC Power Converter with a Single Auxiliary Passive Resonant Snubber

  • Nakamura Mantaro;Myoui Takeshi;Abudullh Al Mamun;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.256-260
    • /
    • 2001
  • This paper presents boost and buck and buck-boost DC-DC converter circuit topologies of high-frequency soft switching transition PWM chopper type DC-DC high power converters with a single auxiliary passive resonant snubber. In the proposed boost power converter circuits operating under a principle of ZCS turn-on and ZVS turn-off commutation schemes, the capacitor and inductor in the auxiliary passive resonant circuit works as the loss less resonant snubber. In addition to this, the switching voltage and current peak stresses as well as EMI and RFI noises can be basically reduced by this single passive resonant snubber. Moreover, it is proved that converter circuit topologies with a passive resonant snubber are capable of solving some problems of the conventional hard switching PWM processing based on high-ferquency pulse modulation operation principle. The simulation results of this converter are discussed as compared with the experimental ones. The effectiveness of this power converter with a single passive resonant snubber is verified by the 5kW experimental breadboad set up.

  • PDF

Short-term demand forecasting Using Data Mining Method (데이터마이닝을 이용한 단기부하예측)

  • Choi, Sang-Yule;Kim, Hyoung-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.126-133
    • /
    • 2007
  • This paper proposes information technology based data mining to forecast short term power demand. A time-series analyses have been applied to power demand forecasting, but this method needs not only heavy computational calculation but also large amount of coefficient data. Therefore, it is hard to analyze data in fast way. To overcome time consuming process, the author take advantage of universally easily available information technology based data-mining technique to analyze patterns of days and special days(holidays, etc.). This technique consists of two steps, one is constructing decision tree, the other is estimating and forecasting power flow using decision tree analysis. To validate the efficiency, the author compares the estimated demand with real demand from the Korea Power Exchange.

PERFORMANCE OF AN OSCILLATING SUBSOILER IN BREAKIN HARD PAN

  • Bandalan, E.P.;Gupta, C.P.;Salokhe, V.M.;Niyamapa, T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1043-1052
    • /
    • 1993
  • Field experiments were conducted to determine the optimum combination of performance parameters of a single-shank, tractor-mounted oscillating subsoiler. Tests were conducted at frequencies of oscillation of 3.7 , 5.67, 7.58, 9.48 and 11.456Hz ; amplitudes of 18, 21, 23.5, 34 and 36.5 mm ; and forward speeds of 1.84, 2.19 and 3.42 kmph at moisture content close to the plastic limit of the soil. It was observed that there was a reduction in average draft but an a increase in average total power requirement for oscillating than non-oscillating subsoiling. The draft and power ratios were significantly affected by the forward speed, frequency and amplitude. Their combined interaction expressed in terms of the velocity ratio parameter( the ratio of peak tool velocity and forward speed) however has the strongest influence. At the same velocity ratio, the draft reduction and power increase were less at higher amplitude of oscillation . As the oscillating frequency is increased toward the soil resonance the draft requirement becomes less. For the field conditions tested. the optimum operation was obtained at an amplitude of 36.5mm, frequency of 9.48Hz and speed of 2.19 kmph with a draft ratio of 0.33 and a power ratio of only 1.24.

  • PDF

스마트 그리드에 그린 IT 활용 연구

  • Jeong, Hyeon-Su;Kim, Byeong-Sik;Wang, Mi-Gyeong;Kim, Jong-Hun;Han, Myeong-Ji
    • Proceedings of the Korea Database Society Conference
    • /
    • 2010.06a
    • /
    • pp.33-41
    • /
    • 2010
  • Recently the number of IT equipment have increased. It consumes large amounts of energy and is emissions of greenhouse gases. Co2 emissions with the PC and the monitor has the highest percentage to 39% more than other IT equipment. In addition, Plan for your PC's power management and technology development is being pursued in developed countries. To reduce energy costs of organizations with large numbers of the PC and to cut down on Co2 emissions, the energy load control technology of ACPI standards-based PC IS suggested. AMI-based PC power-management system was constructed, Approximately 20% of operating a result of the test power consumption was reduced. Looking at the case of the United States, PC monitors from the University of Wisconsin-Oshkosh was Sleep mode. As a result, the monitor on a, $ 20 for a year reduced energy costs. In GE(General Electronic), Approximately 75,000 PC's power setting time was Monitor Off :15 minutes/ Hard Drives Off 30 minutes/ System Standby 30 minutes/ Hibernation mode 2 hours. 1 year, electric bill was $ 2.5 million savings and 3 years electric bill was $ 6.5 million savings. Measuring energy usage data, using the measured data, electric energy management technology is not. Platform development to measure energy usage for Individual energy-consuming equipment is urgently required.

  • PDF