• Title/Summary/Keyword: handling safety and health

Search Result 265, Processing Time 0.025 seconds

The Measurement of Combustible Properties of Cyclopentanol (사이클로펜탄올의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.2
    • /
    • pp.35-40
    • /
    • 2014
  • For the safe handling of cyclopentanol, this study was investigated the explosion limits of cyclopentanol in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash point of cyclopentanol by using closed-cup cyclopentanol was experimented at $49^{\circ}C$. The lower flash points of cyclopentanol by using open cup tester was experimented at $59^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for cyclopentanol. The experimental AIT of cyclopentanol was at $363 ^{\circ}C$.

The Measurement of Fire and Explosion Properties of n-Hexadecane (노말헥사데칸의 화재 및 폭발 특성치의 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.39-45
    • /
    • 2014
  • For the safe handling of n-hexadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-hexadecane were calculated. The lower flash points of n-hexadecane by using the Setaflash and the Pensky-Martens closed testers were measured $128^{\circ}C$ and $126^{\circ}C$, respectively. The lower flash points of the Tag and the Cleveland open cup testers were measured $136^{\circ}C$ and $132^{\circ}C$, respectively. The fire points of the Tag and the Cleveland open cup testers were measured $144^{\circ}C$. respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-hexadecane. The experimental AIT of n-hexadecane was $200^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $128^{\circ}C$ and upper flash point $180^{\circ}C$ for n-hexadecane were 0.42 Vol.% and 4.70 Vol.%.

The Measurement of Fire and Explosion Properties of n-Pentadecane (노말펜타데칸의 화재 및 폭발 특성치의 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.53-57
    • /
    • 2013
  • For the safe handling of n-pentadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-pentadecane were calculated. The lower flash points of n-pentadecane by using closed-cup tester were measured $118^{\circ}C$ and $122^{\circ}C$. The lower flash points and fire point of n-pentadecane by using open cup tester were measured $126^{\circ}C$ and $127^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-pentadecane. The experimental AIT of n-pentadecane was $195^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $118^{\circ}C$ and upper flash point $174^{\circ}C$ for n-pentadecane were 0.54 Vol.% and 6.40 Vol.%.

The Evaluation of Hazard by Measurement of Combustible Characteristics of n-Tetradecane (노말테트라데칸의 연소특성치 측정에 의한 위험성 평가)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.70-76
    • /
    • 2012
  • For the safe handling of n-tetradecane, the lower flash points and the upper flash point, fire point, AITs (auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-tetradecane were calculated. The lower flash points of n-tetradecane by using closed-cup tester were measured $104^{\circ}C$ and $112^{\circ}C$. The lower flash points and fire point of n-tetradecane by using open cup tester were measured $113^{\circ}C$ and $115^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tetradecane. The experimental AIT of n-tridecane was $207^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $104^{\circ}C$ and upper flash point $140^{\circ}C$ for n-tetradecane were 0.63 Vol.% and 3.18 Vol%.

The Measurement and Prediction of the Combustible Properties of of Benzyl-Alcohol for MSDS (Material Safety Data Sheet) (MSDS (Material Safety Data Sheet)를 위한 벤질알코올 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.190-194
    • /
    • 2017
  • The combustion properties for the prevention of the fire and explosion in the work place are flash point, explosion limit, autoignition temperature (AIT) etc.. The using of the corrective combustion properties of the MSDS (Material Safety Data Sheet) of the handling substance for the chemical process safety is very important. For the safe handling of benzyl alcohol which is widely used in the chemical industry, the flash point and the AIT were measured. And, the lower explosion limit (LEL) of benzyl alcohol was calculated by using the lower flash point which obtained in the experiment. The flash points of benzyl alcohol by using the Setaflash and Pensky-Martens closed-cup testers measured $90^{\circ}C$ and $93^{\circ}C$, respectively. The flash points of benzyl alcohol by using the Tag and Cleveland open cup testers are measured $97^{\circ}C$ and $100^{\circ}C$. The experimental AIT of benzyl alcohol by ASTM 659E tester was measured as $408^{\circ}C$. The LEL of benzyl alcohol measured by Setaflash closed-cup apparatus was calculated as 1.17 vol% at $90^{\circ}C$. In this study, it was to possible predict the LEL by using the lower flash point of benzyl alcohol which measured by Setaflash closed-cup tester.

Measurements of Autoigniton Temperature(AIT) and Time Lag of BTX(Benzene, Toluene, Xylenes) (BTX(Benzene, Toluene, Xylenes)의 자연발화온도와 발화지연시간의 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.45-52
    • /
    • 2006
  • The AITs(autoignition temperatures) describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The AITs are often used as a factor in determining the upper temperature limit for processing operations and conditions for handling, storage and transportation, and in determining potential fire hazard from accidental contact with hot surfaces. The measurement AITs are dependent upon many factors, namely initial temperature, pressure, volume, fuel/air stoichiometry, catalyst material, concentration of vapor, time lag. Therefore, the AITs reported by different ignition conditions are sometimes significantly different. This study measured the AITs of benzene, toluene and xylene isomers from time lag using AS1M E659-78 apparatus. The experimental ignition delay times were a good agreement with the calculated ignition delay times by the proposed equations wtih a few A.A.D.(average absolute deviation). Also The experimental AITs of benzene, toluene, o-xylene, m-xylene and p-xylene were $583^{\circ}C,\;547^{\circ}C,\;480^{\circ}C,\;587^{\circ}C,\;and\;557^{\circ}C$, respectively.

Comparison of the Pushing Forces between Horizontal Handle and Vertical Handle According to the Handle Height and Distance (수직형 손잡이와 수평형 손잡이의 높이와 간격에 따른 미는 힘 비교)

  • Song, Young-Woong
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.371-378
    • /
    • 2014
  • Manual materials handling tasks are the main risk factors for the work-related musculoskeletal disorders. Many assistant tools for manual materials handling are being used in various kind of industries. One of them is a 4-wheeled cart which is widely used in manufacturing factories, hospitals, etc. The major force required to control the 4-wheeled cart is pushing and pulling. There are two types of handles being used for the 4-wheeled cart : vertical type (two vertical handles), and horizontal type (one horizontal handle). This study tried to investigate the pushing forces and subjective discomforts (hand/writst, shoulder, low back, and overall) of the two handle types with different handle height and distance conditions. Twelve healthy male students (mean age = 23.4 years) participated in the experiment. The independent variables were handle angle (horizontal, vertical), handle height (low, medium, high), and handle distance (narrow, medium, wide). The full factorial design was used for the experiment and the maximum pushing forces were measured in 18 different conditions ($2{\times}3{\times}3$). Analysis of variance (ANOVA) procedure was conducted to test the effects of the independent variables on the pushing force and discomfort levels. Handle height and angle were found to be the critical design factors that affect the maximal pushing forces and subjective discomfort. In the middle height, subjects exerted higher pushing forces, and experience lower discomfort levels compared to the high, and low height. There was no statistical influence of the handle distance to the pushing forces and subjective discomfort levels. It was found out that the effects of the handle angle (horizontal and vertical) on both pushing force and subjective discomfort were statistically significant (p < 0.05). The vertical handle revealed higher pushing force and lower discomfort level than the horizontal handle. The reason for that was thought to be the different postures of the hand when grasping the handles. The horizontal handle induced pronaton of the hand and made hand posture more deviated from the neutral position.

Measurement and Prediction of Autoignition Temperature (AIT) and Ignition Delay Time of n-Pentanol and p-Xylene Mixture (n-Pentanol p-Xylene 과 혼합물의 최소자연발화온도와 발화지연시간의 측정 및 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.1-6
    • /
    • 2017
  • The fire and explosion properties of combustible materials are necessary for the safe handling, storage, transportation and disposal. Typical combustion characteristics for process safety include auto ignition temperature(AIT). The AIT is an important index for the safe handling of combustible liquids. The AIT is the lowest temperature at which the material will spontaneously ignite. In this study, the AITs and ignition delay times of n-pentanol and p-xylene mixture were measured by using ASTM E659 apparatus. The AITs of n-pentanol and p-xylene which constituted binary system were $285^{\circ}C$ and $557^{\circ}C$, respectively. The experimental AITs and ignition delay times of n-pentanol and p-xylene mixture were a good agreement with the calculated AITs and ignition delay times by the proposed equations with a few A.A.D. (average absolute deviation). Therefore, it is possible to estimate the AITs and ignition delay times in other compositions of n-pentanol and p-xylene mixture by using the predictive equations which presented in this study.

Comparative Study of Korean Workers' Exposure to Dichloromethane by Process Category between Work Environment Monitoring Program and ECETOC TRA (국내 디클로로메탄 제조·사용 사업장 근로자의 공정별 노출수준에 대한 작업환경측정값과 ECETOC TRA 모델값 비교연구)

  • Jeong, Sujin;Bae, Gyewan;Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.317-330
    • /
    • 2021
  • Objectives: By law, companies in Korea must periodically measure workers' exposure to harmful chemicals (the system is called the Work Environment Monitoring Program (WMP)[a]) and report the results to the government. The government also measures exposure to monitor the WMP's reliability (called Reliability Assessment (RA) for WMP[b]). The issue is that measured data from these two sources are so different that the objectivity of WMP needs to be confirmed by comparing the results using the European Centre for Ecotoxicology and Toxicology of Chemicals' Targeted Risk Assessment (ECETOC TRA). Methods: Step 1: Data collection from WMP reports submitted by companies (n=586) and RA for WMP written by the government (n=33). Step 2: Data Standardization by key information included. Step 3: Data conversion to input-variables required to run the ECETOC TRA model, and run the model with specific data (n=514) which meet the predetermined exposure scenario. Step 4: Statistical data analysis by process category (PROC) and ventilation type from each source ([A] and [B]). Step 5: Additional analysis of any unexpected results. Results: The process categories of the production and handling of Dichloromethane were classified into 12 PROCs, and ten of them were selected to run ECETOC TRA. Modeled values tended to be higher than measured values from both sources. For the measured values from WMP, RCR distribution by PROC was narrow (0.197-0.267, 95% CI) and did not have a relationship with ventilation type, which differs from the tendency of the modeling result. Meanwhile, the measured values from RA for WMP were relatively widely distributed (0.301-1.177, 95% CI) by PROC. In particular PROCs (13,19) were high enough to exceed 1. Also, they become low with better ventilation types and appear differently depending on the ventilation type, similar to the model result. Conclusions: This study revealed that ECETOC TRA might have the potential to serve as a screening tool for exposure assessment and to be used as assistive method for WMP to estimate exposure. Further empirical study is required to confirm its availability as a screening tool.

Measurement and Prediction of the Combustible Properties of Propionic Anhydride (Propionic Anhydride의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.66-72
    • /
    • 2016
  • For the safe handling of Propionic Anhydride being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of Propionic Anhydride was experimented. And, the lower explosion limit of propionic anhydride was calculated by using the lower flash point obtained in the experiment. The flash points of propionic anhydride by using the Setaflash and Pensky-Martens closed-cup testers measured $60^{\circ}C$ and $61^{\circ}C$, respectively. The flash points of propionic anhydride by using the Tag and Cleveland open cup testers are measured $67^{\circ}C$ and $73^{\circ}C$. The AIT of propionic anhydride by ASTM 659E tester was measured as $280^{\circ}C$. The lower explosion limit by the measured flash point $60^{\circ}C$ was calculated as 1.37 Vol.%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.