• 제목/요약/키워드: hall measurement

Search Result 492, Processing Time 0.028 seconds

Application of Vibration Prediction Method Using Response Spectrum with Amplification Factor (증폭계수를 이용한 진동 예측기법의 적용)

  • 심재수;황의승;김덕중;윤종오
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.37-43
    • /
    • 1997
  • Damages and public complaints are increased due to construction noise and vibration from several sources. It is urgently needed to develop the easy and practical method to estimate the vibration effect. In this study, to predict the vibration effect, the method using the response spectrum with amplification factor concepts prroposed by Newmark and Hall is used. Also the applicability of the method is examined. Vibration measurement on subway structure, foundation and building structures are performed and the results show that the provided method is practical and can be used to predict the vibration effect.

  • PDF

Carrier Densities of CdSe Thin Films (CdSe 박막반도체의 반송자 밀도)

  • 김기원
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.7-10
    • /
    • 1984
  • Generally, free carrier densities of single crystal semiconductors are indifferent to methods of measurement. Free carrier densities of CdSe thin films, however, were measured invarious values with different methods In this paper, C-V method, Seebeck effect and a.c. Hall effect were used to measure carries densities of CdSe thin films. Carrier densities of CdSe thin films were in the range of 10 - 10 carriers/㎤. And causes of different results were discussed.

  • PDF

Position Detection of a Capsule-type Endoscope by Magnetic Field Sensors (자계 센서를 이용한 캡슐형 내시경의 위치 측정)

  • Park, Joon-Byung;Kang, Heon;Hong, Yeh-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.66-71
    • /
    • 2007
  • Development of a locomotive mechanism for the capsule type endoscopes will largely enhance their ability to diagnose disease of digestive organs. As a part of it, there should be provided a detection device of their position in human organs for the purpose of observation and motion control. In this paper, a permanent magnet outside human body was employed to project magnetic field on a capsule type endoscope, while its position dependent flux density was measured by three hall-effect sensors which were orthogonally installed inside the capsule. In order to detect the 2-D position data of the capsule with three hall-effect sensors including the roll, pitch and yaw angle, the permanent magnet was extra translated during the measurement. In this way, the 2-D coordinates and three rotation angles of a capsule endoscope on the same motion plane with the permanent magnet could be detected. The working principle and performance test results of the capsule position detection device were introduced in this paper showing that they could be also applied to 6-DOF position detection.

Design of High-Response Speed Control System for AC Servomotor Drive (유도형 교류 서보전동기의 고응답 구동회로 설계에 관한 연구)

  • 성영권;조철제
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.5
    • /
    • pp.474-482
    • /
    • 1992
  • This paper describes the speed control system of an induction type ac servomotor drive on the vector control basis of slip frequency and constant secondary flux control for a quick torque response. The system is composed of a digital controller using a SCB-V50 microprocessor and a PWM inverter with power MOSFETs for high speed switching. And, for the measurement of actual instantaneous currents, MDCS A070-051 hall sensors are employed. The rising time of step responce by this system through the test of a 600[W] ac servomotor is 30[ms]. Overall experimental result shows that the drive performance of the system is similar to that of a separately excited armature current control of a dc motior.

  • PDF

A Study on the development of gas metering valve system (가스 계량 밸브 시스템의 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.4
    • /
    • pp.200-204
    • /
    • 2014
  • LPG is used in the home would have to depend on the provider, because there is no method for measuring the capacitance. In addition, by measuring the gas capacities can not be known because of the LPG gas replacement time and requires an alarm for replacement. In this study, and that the gas capacities to the trusted user and the supplier, in order to know when it is time to change to LPG gas by applying a Hall effect sensor developed a gas capacities measurement the valve system.

Electric conduction mechanism Analysis of AW Thin Films using XPS Measurement (XPS 분석에 의한 AZO 박막의 전기전도 메커니즘 해석)

  • Jin, Eun-Mi;Kim, Kyeong-Min;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.446-447
    • /
    • 2007
  • Aluminisum-doped zinc oxide (AZO) films are attractive materials as transparent conductive electrode because they are inexpensive, nontoxic and abundant element compared with indium tin oxide (ITO). In our paper, AZO films have been deposited on glass (coming 1737) substrates by RF magnetron sputtering. The AZO film was post-annealed at $600^{\circ}C$, $800^{\circ}C$ for 2 hr with $N_2$ atmosphere, respectively. We investigated that the electric properties and qualitative analysis of AZO films, which measured using the methods of Hall effect, X-ray photoelectron spectroscopy (XPS).

  • PDF

Current sharing measurement using non-contact method for parallel HTS tapes conductor according to tape array geometry (병렬도체에서 선재의 배열형상에 따른 비접촉식 전류분류 측정)

  • Byun, S.;Park, M.;Choi, S.;Park, S.;Lee, S.;Kim, W.;Lee, J.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.1
    • /
    • pp.32-36
    • /
    • 2008
  • An HTS conductor with parallel HTS tapes is essential for a large power HTS device to flow a large current. One of the most important factor for this conductor is a current distribution. Non-uniform current distribution in parallel tapes makes the critical current of the conductor low and the AC losses high. In this paper we proposed a non-contact method which measured each current in parallel tapes by using an array of Hall sensors. A matrix can be derived from this array for calibration. The current distributions of 4 and 6 parallel tapes were measured.

Structure and Electrical Properties of PbTe Thin Film According To The Substrate Temperature (기판온도에 따른 PbTe 박막의 구조 및 전기적 물성)

  • Lee, Hea-Yeon;Choi, Byung-Chun;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.184-188
    • /
    • 1999
  • PbTe thin films of high quality were deposited on HF-treated Si(100) substrates at various substrate temperature by pulsed laser deposition technique. XRD patterns showed that PbTe layers were well-crystallized to a cubic phase with (h00) preferred orientation with the substrate temperature up to $300^{\circ}C$. PbTe films could not form at substrate temperature above $400^{\circ}C$ because of reevaporation of the Pb. According to AFM image, the surface of films was composed of small granular crystals and flat matrix. According to the increase of substrate temperature, the grain size at film surface becomes larger. By Hall-effect measurement, the carrier concentration and Hall mobility of n-type PbTe films grown by $T_{sub}=300^{\circ}C$ were $3.68{\times}10^{18}cm^{-3}$ and $148\;cm^2/Vs$, respectively.

  • PDF

Improvement and Change of Acoustic Performance of University Small Hall Remodeled as Exclusive for Lecture Room : Based on the case of the W University (강의전용 공간으로 리모델링된 대학 소공연장의 음향성능 개선 및 변화 : W대학의 사례를 바탕으로)

  • Kim, Min-Ju;Kim, Jae-Soo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.19 no.2
    • /
    • pp.21-31
    • /
    • 2020
  • The purpose of this study was to analyze the contents of the sound environment among the various environmental factors that directly or indirectly affect the quality of education through the remodeling of the small hall of the College of Humanities at W University. Before remodeling into a lecture room, the small hall of the College of Humanities at W University, which is the subject of this study, was designed to create an indoor sound environment suitable for a lecture room by recognizing differences in acoustic performance between the performance halls that require adequate sound quality and the lecture rooms where the clarity of voice is important. Therefore, this study aimed to present examples of improved acoustic performance in lecture rooms by remodeling through the stages of measuring acoustic performance before remodeling, presentation of a change in finishing materials through sound simulation, and measurement of sound performance after remodeling. It is expected that this process can be used as an example of securing indoor acoustic performance suitable for educational space, such as lecture rooms, by changing the finishing materials.

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.