• Title/Summary/Keyword: growth retardant

Search Result 44, Processing Time 0.034 seconds

Early Growth of Sweet Pepper by Difference between Day and Night Temperature after Planting (정식 후 주야간온도차에 따른 착색단고추의 초기 생육)

  • Kim, Ho Cheol;Ku, Yang-Gyu;Lee, Yong Beom;Lee, Jeong Hyun;Choi, Joon Ho;Bae, Jong Hyang
    • Horticultural Science & Technology
    • /
    • v.31 no.5
    • /
    • pp.552-557
    • /
    • 2013
  • This study was carried out to investigate the different DIF (day/night temperature differential) treatments on early growth of sweet pepper plants (Capsicum annuum L.) after planting. The DIF treatments were thus as follows. DIF levels are DIF-6 ($20-26^{\circ}C$) and DIF 0 ($23^{\circ}C$), DIF 3 ($24.5-21.5^{\circ}C$) and DIF 6 ($26-20^{\circ}C$). The DIF 3 and DIF 6 treatments significantly increased plant height of the sweet pepper plants during ten weeks after planting compared to DIF-6 and DIF 0. Leaf area per plant of DIF 3 treatment constantly increased and the level was greatest leaf area at ten weeks after planting. Fresh weight per plant treated with DIF-6 was lower and was reduced 74-77% range compared to other treatments. DIF 0 and DIF 3 treatments significantly affected dry weight and percentage of dry matter compared to DIF-6 and DIF 6. Especially DIF 6 treatment significantly decreased from eight weeks after planting. Percentage of dry matter of the leaf treated with DIF 0 and DIF 3 consistently increased from six weeks after planting, however, DIF-6 and DIF 6 treatments dramatically decreased from eight weeks after planting. High levels of DIF management cause growth retardant on early growth of sweet pepper plants, especially when night temperature is higher than day temperature, plants are indicated to be greater growth retardant.

Growth Regulation of Korean Lawngrass and Manilagrass with Several Growth Retardants (잔디류식물에 있어 생장억제제시용효과에 관한 연구)

  • 심재성
    • Asian Journal of Turfgrass Science
    • /
    • v.3 no.1
    • /
    • pp.39-52
    • /
    • 1989
  • Native Kerean lawngrass (Zeysia japonica steud.) and Manilagrass ( Zeysia matrella Merr.) are frequently used as sport turf and lawn in Kerea and ether Asian countries because of its excellent summer qualities and superior winter-hardiness compared to ether warm-season turfgrass . The objective of this study was to investigate the effect of the plant growth retardants ( PGR ) en the inhibition (d the growth of the two Kerean native turfgrasses. Kerean lawngrass and Manilagrass were treated with [2 RS , 3 RS] -1- [4- chlorophenyl ] -4, 4-dimethyl -2- [1 H -1, 2, 4- tiazol -1- y] pentan -3- ol ( PP -333) at 93 and 930 gha -j ; 5-[4- chlorphenyl ]-3, 4, 5, 9, 10- peiitaaza - tetracyclo [5, 4, 1, 0 2 6 . o ~'~I -3, 9- diene ( BAS -106) at 16 and 160 gha ; [ E I-] - cyclohexyl -4, 4- dimethyl -2- [1, 2, 4- triazol -1- yl ]-1-pentene - 3- ol ( NTN -821) at 56 and 560 gha ', and 4- chloro -2- [$\alpha$- hydrozybenzy I isonicotin anilide ( CGR -811) at 92 gha in pot study . All PGR treatments were effective in reducing the plant height, with the exception of BAS -106 at 16 gha for Korean lawngrass ; however , all increased quality to some degree , with the exception of PP -333 at 93 gha . The low PGR rates significantly increased Korean lawngrass height during late jtily aitd mid-August . On the other hand , BAS -106 significantly increased Manilagrass height {rom 24 Septeml)er onwards . All PGR treatments haol higher turfgrass quality than untreatments , and also the high rates of PGIt treatments were more effective in increasing quality than the low rates observed on 8 October . Meanwhile , Manilagrass quality was increased to some extent than Korean lawegrass . PP - 333 was significantly effective in reducing clipping yield and the same results were found with the application of NTN -821 at 560 gha -l for both Korean lawngrass and Manilagrass , BAS -106 at 160 gha for Korean lawegrass , and CGR -811 at 92 gha for Manilagrass . The high PGR rates had higher turfgrass shoot weight observed on 8 October than the low rates , and there were little increases obtained with the low rates of PP -333 for Korean lawngrass and BAS - 1 06 for Manilagrass . Effeets on stolon growth varied between growth retardants , and between retardant treatments ; the high rates of PGR as well as the low rate of NTN -821 elongated stolon of Korean lawngrass and manoilagrass . However , PP -333 at 93 gha and BAS -106 at 16 gha - shortened stolons of Korean lawugrass , resulting in inhibition or little difference of stolon dry weight . NTN -821 at 560 gha and CGR -811 had no positive effect on the stolon length of Manilagrass . 101) -333 and the low rate of BAS -106 and NTN -821 decreased root weight of Korean lawng - rass All PGR rates had negative effect on the root weight of Manilagrass with the exception of BAS -106 CR -811 and the high rate of NTN -821 which made no difference in root weight between retarolant treatments and the control .

  • PDF

Height Control of Pot Chrysanthemum according to Daminozide Applications at Different Planting Period in C-Channel mat Irrigation System (C-형강 매트 저면관수 시스템을 이용한 분화 국화 재배 시 정식시기와 Daminozide 처리에 따른 초장 조절)

  • Kang, Seung Won;Seo, Sang Gyu;Lee, Gung Pyo;Pak, Chun Ho
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2011
  • Effect of daminozide concentration and application methods, in combination with different planting period, on the growth of chrysanthemum was investigated for small pot-plant production. Daminozide, a plant growth regulator widely used for plant height control, was applied by drench or sub-application. For pot chrysanthemums of first planting time, plant height was reduced over $4,000mg{\cdot}L^{-1}$, when daminozide was drenched directly into the pot medium. However, $5,000mg{\cdot}L^{-1}$ of daminozide drench affected plant height reduction for secondarily planted pot chrysanthemum. Analysis of variance revealed the plant height was affected by planting time. For sub-application experiment of daminozide, it showed that the daminozide affected the number of flower buds formation and fresh and dry weight. These results suggest that planting period affected growth retardation of chrysanthemum. Therefore, application of growth retardant in combination with planting time and application methods may provide more efficient growth control for pot-chrysanthemum production.

Effect of Diniconazole on Growth and Flowering of Vinca rocea and Salvia splendis (Diniconazole 처리가 일일초와 샐비어의 생장 및 개화에 미치는 영향)

  • Choi, Sung-Hwan;Kang, Jum-Soon;Choi, Young-Whan;Lee, Yong-Jae;Park, Young-Hoon;Kim, Mi-Ra;Son, Beung-Gu;Kim, Hyeun-Kyeung;Kim, Hong-Yul;Oh, Wook;Sim, Hak-Bo;Lim, Ki-Byung;Kim, Jin-Ki
    • Journal of Life Science
    • /
    • v.21 no.7
    • /
    • pp.1004-1008
    • /
    • 2011
  • This study was conducted to investigate the effects of uniconazole (Sumiseven), an existing expensive growth retardant, and diniconazole (Binnari), used as a cheap germicide, on the growth and flowering of Vinca major and Salvia splendis for the possibility of substitution for expensive growth retardants. The growths of V. major and S. splendis were retarded by Binnari treatment. The effect of Binnari 100 mg/l treatment was higher than that of Sumiseven 5 mg/l treatment in both plants. The length of leaves was remarkably retarded by Binnari treatment, however, the width of leaves was only slightly retarded, giving the leaf a round shape. The number of days to flowering was increased by Binnari treatment in both in V. major and S. splendis. The number of days to flowering in V. major showed no significant difference compared to the control except by treatemtn with Binnari 400 mg/l. The number of florets of S. splendis increased with treatment with Binnari 100 and 200 mg/l.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Effects of Trinexapac-ethyl on Lodging-related Traits in Transplanted Rice

  • Han, Sang-Wook;Park, Jung-Soo;Cho, Young-Cheol;Lim, Gab-June;Ju, Young-Cheoul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.3
    • /
    • pp.186-190
    • /
    • 1999
  • The objective of this study was to ,determine trinexapac-ethyl [4-(cyclopropyl- $\alpha$ -hydroxy-me-thylene)-3,5-dioxocyclohexanecarboxylic acid ethyl ester] effects on lodging-related traits of rice varieties treated at different application rates and times. Trinexapac-ethyl WP was applied at the rate of 10, 20 and 30g ai/l0a to Heukjinjubyeo and Daeanbyeo, respectively. Effects of trinexapacethyl varied greatly with application time as well as application rate with little differences between rice varieties. As the application rate increased, lodging index, center of gravity and exsertion of panicle above flag leaf decreased, whereas breaking strength and phytotoxicity increased. Exsertion of panicle was greatly influenced by the application time with a little difference by application rate. The most effective application time of trinexapac-ethyl based on lodging index and total internode length (Ist-4th node) was 2DBH(days before heading) in Heukjinjubyeo and 17DBH in Daeanbyeo, resulting in reducing total internode length by 12.9 and 9.7cm, respectively. A significant reduction was found at the 1st, 2nd, and 3rd internodes in Heukjinjubyeo, while at the 2nd and 3rd internodes in Daeanbyeo. No significant difference was found among treatments in the panicle length of both rice varieties but the panicle fresh weights of Daeanbyeo were significantly greater in all trinexapac-ethyl treatments compared with that of the control when measured 20 days after heading. Consequently, trinexapacethyl treatment significantly improved lodging-related traits of rice plants without affecting rice yield and yield components.

  • PDF

A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA (침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성)

  • Lee, Jae-Pil;Lee, Chung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

Effect of Day and Night Temperatures on Flowering after Spraying Benzyladenine (BA) in Cymbidium ensifolium 'Tekkotsusosin' (BA살포후 주야 온도처리가 동양란 '철골소심'의 개화에 미치는 영향)

  • Lee, Young-Ran;Kim, Jae-Yeong;Kim, Byeong-Hyeon
    • Horticultural Science & Technology
    • /
    • v.17 no.6
    • /
    • pp.755-757
    • /
    • 1999
  • This study was conducted to investigate the optimum temperature after BA treatments for the indution of flowering in Cymbidium ensifolium 'Tekkotsusosin'. Flowering rate was 90% at $30/25^{\circ}C$ (day/night), 50% at $25/20^{\circ}C$ and the natural condition as control, and non flowering at $20/15^{\circ}C$. Malformation rate of flower shape was at $25/20^{\circ}C$, 4% at $30/25^{\circ}C$, and 9% in the natural condition. The length and number of flowering stalks per plant were most at $30/25^{\circ}C$ treatment. After BA spraying, the lowest air temperature for flowering was assumed to be about $20^{\circ}C$.

  • PDF

Analysis of Vertical Combustion and Carbonization Patterns of Floor Materials When Using a Needle Flame (니들 플레임에 의한 바닥재의 수직 연소 및 탄화 패턴의 해석에 관한 연구)

  • Park, Min-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.101-106
    • /
    • 2020
  • This study analyzed flame growth characteristics and carbonization patterns when floor materials were burned vertically using a needle flame produced for this study. It was found that PVC flooring was fire retardant and the area under direct flame contracted inward. Vertical combustion causes solidification in the form of a lump at the bottom and also generates soot in a pattern that progresses upwards. This study found that laminated flooring exhibited no fire retarding characteristics and that the laminated layer of its upper surface was destroyed by fire, causing irregular delamination. The carbonization ranges at the left and right sides were determined to be symmetrical. A vertical combustion test of a sample carpet showed that it exhibited no fire-retarding characteristics. It was observed that if heat accumulated in the carpet, the flame formed an ascending air current, and that when flammable materials were present around the flame, they further accelerated the diffusion of the flame. The carbonization pattern at the carpet surface exposed to direct flame revealed that the carpet surface had melted and had flown downwards and that many tiny holes formed on it.

Flexural response of steel beams strengthened by fibre-reinforced plastic plate and fire retardant coating at elevated temperatures

  • Ahmed, Alim Al Ayub;Kharnoob, Majid M.;Akhmadeev, Ravil;Sevbitov, Andrei;Jalil, Abduladheem Turki;Kadhim, Mustafa M.;Hansh, Zahra J.;Mustafa, Yasser Fakri;Akhmadullina, Irina
    • Structural Engineering and Mechanics
    • /
    • v.83 no.4
    • /
    • pp.551-561
    • /
    • 2022
  • In this paper, the effect of fire conditions according to ISO 834 standard on the behavior of carbon fibre-reinforced plastic (CFRP) reinforced steel beams coated with gypsum-based mortar has been investigated numerically. To study the efficiency of these beams, 3D coupled temperature-displacement finite element analyzes have been conducted. Mechanical and thermal characteristics of three different parts of composite beams, i.e., steel, CFRP plate, and fireproof coating, were considered as a function of temperature. The interaction between steel and CFRP plate has been simulated employing the adhesion model. The effect of temperature, CFRP plate reinforcement, and the fireproof coating thickness on the deformation of the beams have been analyzed. The results showed that within the first 120 min of fire exposure, increasing the thickness of the fireproof coating from 1 mm to 10 mm reduced the maximum temperature of the outer surface of the steel beam from 380℃ to 270℃. This increase in the thickness of the fireproof layer decreased the rate of growth in the temperature of the steel beam by approximately 30%. Besides excellent thermal resistance and gypsum-based mortar, the studied fireproof coating method could provide better fire resistance for steel structures and thus can be applied to building materials.