• Title/Summary/Keyword: grounding method

Search Result 293, Processing Time 0.033 seconds

Residual ultimate strength of a very large crude carrier considering probabilistic damage extents

  • Choung, Joonmo;Nam, Ji-Myung;Tayyar, Gokhan Tansel
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.1
    • /
    • pp.14-26
    • /
    • 2014
  • This paper provides the prediction of ultimate longitudinal strengths of the hull girders of a very large crude carrier considering probabilistic damage extent due to collision and grounding accidents based on IMO Guidelines (2003). The probabilistic density functions of damage extent are expressed as a function of non-dimensional damage variables. The accumulated probabilistic levels of 10%, 30%, 50%, and 70% are taken into account for the estimation of damage extent. The ultimate strengths have been calculated using the in-house software called Ultimate Moment Analysis of Damaged Ships which is based on the progressive collapse method, with a new convergence criterion of force vector equilibrium. Damage indices are provided for several probable heeling angles from $0^{\circ}$ (sagging) to $180^{\circ}$ (hogging) due to collision- and grounding-induced structural failures and consequent flooding of compartments. This paper proves from the residual strength analyses that the second moment of area of a damage section can be a reliable index for the estimation of the residual ultimate strength. A simple polynomial formula is also proposed based on minimum residual ultimate strengths.

An Effective Installation Method of Lightning Protective Devices for Information and Communication Facilities (정보통신설비에 대한 뇌서지 보호소자의 효과적인 설치기법)

  • Lee, B.H.;Kang, S.M.;Eom, J.H.;Lee, D.M.;Lee, S.B.;Jeong, D.C.;Ahn, C.H.;Jeon, D.K.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1754-1756
    • /
    • 2002
  • This paper deals with an effective installation method of lightning protective devices for information and communication facilities. Due to the potential difference between grounding of the AC power lines and communication lines, the equipments connected to the communication lines are easily damaged by lightning surges. So we have examined the behaviors of surge protective devices against lightning surges from the AC power lines and signal lines, and the coordination effects of SPD installation method were investigated. As a result, it was confirmed that the bypass arrester method and common grounding method were very effected.

  • PDF

Evaluations of Dangerous Voltages around Grounding Electrode using Small-sized Model (축소모델을 이용한 접지전극 주변의 위험전압 평가)

  • Baek, Young-Hwan;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.83-88
    • /
    • 2010
  • In this paper, to propose a valid method solving a problem relevant to grounding from actual field data, the experimental results relevant to touch and step voltages and surface potential profiles measured around the real-sized and small-sized grounding electrode models were described. The ground surface potential profiles and dangerous voltages around the concrete pedestals employed in street facilities such as street lamps, traffic signal lamp and controllers as a case study were measured and discussed. The hemispherical cell with a diameter of 1,160[mm] was employed to simulate uniform soil. As a result, the results measured with the small-sized model were in reasonably agreement with the data obtained from the real-sized installation. It was found that the small-sized model test could be employed as a useful means evaluating the dangerous voltages around grounding electrodes installed at the inaccessible areas such as mountains, underground, underwater, and so on.

Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter (저항접지 시스템에서 지락사고시 CLR과열 소손방지를 위한 GPT 정격용량의 적정성 연구)

  • Shin, Ho-Jeon;Kim, Jin-Seok;Park, Yu-Hwan;Kim, Jae-Chul;Cho, Man-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.503-508
    • /
    • 2012
  • Among the high distribution voltage consumers, high-capacity consumers are often applying the grounding resistance method in order to overcome demerits such as erroneous operation of the ground reply or potential increase in the battery at the accident of the isolated neutral system. In this paper, to prevent damage to CLR and GPT in the delay to block the breakdown in the resistance grounded neutral system, this study aims to provide a proper suggestion for continuous rating capacity of GPT to check the appropriateness of CLR size and reduce GPT burden. Thereupon, this study comparatively analyzes CLR current applied in general GPT and the current gained when CLR demanded in the system is used and analyzes the simulated system through simulation using PSCAD/EMTDC in order to suggest GPT's proper continuous rating capacity.

위험전압 측정기의 설계 및 제작

  • Jang, Un-Yong;Park, Dae-Won;Han, Ju-Seop;Gil, Gyeong-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.25-25
    • /
    • 2010
  • This paper describes the design and fabrication of a Risk Voltage Meter (RVM) which can analyze the step and touch voltages in grounding systems. The meter consists of a sine-wave power source which generates up to 300 [$V_{rms}$] in ranges of 45 [Hz]~1 [kHz], a 8 Ch. data acquisition module, and a personal computer. Also, a noise elimination method by a digital band-pass filter during measurement is proposed.

  • PDF

Improvement of Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line (웨이브렛을 이용한 혼합송전선로에서의 거리계전 알고리즘 개선)

  • 정채균;김경호;하체웅;이종범;윤양웅
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.593-601
    • /
    • 2003
  • Distance realy is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding resistance, and sheath voltage limiters(SVLs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable systems, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using D1 coefficient summation in db4. And also, error compensation value was proposed for correct calculation of impedance in power cables section.

Shapes Factor Estimation of Grounding Electrode by Water Tank Model (수조모델에 의한 접지전극의 형상계수추정)

  • Koh, Hee-Seog;Choi, Jong-Kyu;Ji, Bong-Ho;Lee, Hyun-Moo;Kim, Ju-Chan;Lee, Chung-Sik;Park, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.365-367
    • /
    • 2001
  • We are explaining shapes factor of ground electrode in a rectangular parallelepiped which is based on analysis of a hemisphere electrode. Actually, a hemisphere electrode is hardly used in a plan and construction, because it is difficult for somebody to use one. This thesis describes the method of grounding resistance estimation which is used the water tank model and electrode shopes factor.

  • PDF

A study on the system to evaluate the performance of novel ground apparatus (신개발 접지장치의 성능평가시스템에 관한 연구)

  • Park, Sang-Man;Jang, Sang-Ok;Park, Chang-Ho;Kang, Moon-Ho;Choi, Jong-Kee;Lee, Mun-Seok;Choi, Ha-Ok;Lee, Yong-Han;Hwang, Kwang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2666-2668
    • /
    • 2003
  • The most widely employed grounding apparatus in distribution systems is a driven rod. But this method has some difficulties to get a specified ground resistivity in cities or islands. Recently, the new ground apparatus are proposed. This paper describes the research which relates with the system to evaluate the performance of novel grounding apparatus.

  • PDF

TGPR Characteristic Analysis for Lightning Surge (뇌써지에 의한 과도 대지전위상승 특성 분석)

  • Lee, J.B.;Myung, S.H.;Chang, S.H.;Cho, Y.G.;Kim, J.S.;Kil, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1641-1643
    • /
    • 2003
  • Transient GPR characteristics of two different grounding systems were measured in this paper. The scale model method was used to analyze the effectiveness of bonding two grounding grids systems. Also the measured results were verified by comparing with Pspice analysis results.

  • PDF

Estimation of Soil Resistivity Parameter for Optimal Grounding Design (최적 접지설계를 위한 대지파라메터의 추정)

  • Lee, Hyung-Soo;Lee, Kwan-Hyung;Lee, Bong-Yong;Shim, Keon-Bo
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.61-63
    • /
    • 1994
  • Accurate estimation of soil resistivity parameters are very important in the design of grounding systems. This paper presents a useful methodology for the optimal estimation of soil parameters based on the weighted least square concepts using a set of earth resistivity measurements by Wenner method. And, this paper developes a computer simulation programming for the estimation of soil parameters. Results are presented and compared with the results of other methods.

  • PDF