• Title/Summary/Keyword: grounding design

Search Result 170, Processing Time 0.024 seconds

Frequency Dependent Grounding Impedance As a Function of Soil Resistivity (대지저항률에 따른 접지임피던스의 주파수 의존성)

  • Bae, Sung-Bae;Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • A design criterion of grounding systems is commonly based on low frequency resistance in Korea. When lightning surges which have high frequency components are injected into the grounding system, the grounding impedance is greatly different from the static grounding resistance. This paper presents the grounding adimittance and phase on the frequency range from 100 [Hz] to 15 [MHz] using water tank simulating the grounding system in different water resistivities. As a result, capacitive effect is dominant over the frequency of 100 [kHz] at the water resistivity of 1,000 [$\Omega$ m]. On the other hand, the inductive characteristics appear at the low water resistivity. Consequently, dependence of grounding impedances on the frequency of injected current is strongly related to resistivity.

  • PDF

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

Design and A Safety Analysis and Assessment of a Grounding System according to International Standards (국제 표준(IEC)에 의한 접지 설계 및 이에 대한 안전성 분석·평가)

  • Kim, Doo-Ung;Cho, Man-Hyung;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.54-59
    • /
    • 2015
  • In this paper, we evaluate safety of grounding system which is designed according to IEC standards. Safety assessment of construction site and grounding system of building is needed before construction for the safety of human in building. Until now, in case of domestic field, design of grounding system is proceeded based on methods which are proposed in IEEE Std. 80. In other words, it is not in the situation that grounding system is designed based on IEC standards. Therefore, we propose a method which designs grounding system and evaluates safety of it according to IEC standards. We measure ground resistance of construction site using measuring equipment of ground resistance. Using this value, soil structure and ground resistivity are obtained through program analysis. CDEGS program of SES company is used for simulation analysis.

Recent Trend of International Standards on the Safety Criteria for Electric Shock Protection (인체감전 안전기준에 관한 최근 국제규격의 동향)

  • Lee, Jong-Chul;Kim, Han-Soo;Lee, Ju-Chul;Kang, Sung-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.189-193
    • /
    • 2007
  • The grounding of an electrical system is one of the essential elements for public safety. Domestic practice of grounding system design has been to get grounding resistance values which are classified by facilities or equipment in the regulations. But the concept of grounding system design of IEC is, as a main factor of safety index, to consider touch voltage and step voltage instead of the resistance value itself. Recently IEC actively develops or revises safety related standards which are essential for the grounding system performance. In this paper, we present the recent trend of the international standards on the safety criteria for Electric Shock Protection.

  • PDF

A study of grounding system design with economical efficiency in electric rolling stocks facilities (철도차량기지내에서의 경제성을 고려한 접지설계에 관한 연구)

  • Chang, Chin-Young;Kim, Jae-Moon;Kim, Yang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.6-9
    • /
    • 2009
  • Recently, there have been studied the importance of the grounding system, as electrical equipments installed in the building, such as intelligent building. The object of grounding of electrical facilities is to protect human and machine damage from the power supply interruption high voltage by use of the accident current dissipating into the ground. In this paper, we is proposed to design of grounding system with economical efficiency in electric rolling stocks facilities. To make efficient ground, ground potential rise must be controlled in the way of overall lowering and evenness instead of independent grounding method with respect to electrical facilities.

  • PDF

Effects of Maximum Probe Spacing of Wenner Method on Substation Grounding (변전소 접지설계를 위한 대지저항율 측정시 전극간격이 해석결과에 미치는 영향)

  • Choi, J.K.;Kee, H.C.;Jung, G.J.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2355-2357
    • /
    • 1999
  • Estimating equivalent soil model which represents an actual soil structure and its electrical characteristics, is extremely improtant for good substation grounding system design and analysis. Since the equivalent soil model is deduced based on the measured apparent soil resistivity - generally obtained from Wenner's 4-point method, reasonable and accurate measuring technique and procedure guarantee good grounding system design and analysis. The paper aims to show the importance of reasonable enough probe spacing by presenting the influence of soil modelling to estimation and measurement of grounding resistance of substation grounding grid.

  • PDF

A Case of Reducing Grounding Resistance of 154KV Substation (154KV 변전소의 접지저항 저감대책 검토사례)

  • Kee, H.T.;Choi, J.K.;Jung, G.J.;On, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2064-2067
    • /
    • 2000
  • In our country, most region is composed of mountains and people have recently been displeased with the construction of the substations in their vicinity so the substations newly built are mainly constructed with GIS system in the small area that has high soil resistivity near mountain. Therefore, nowadays the design of substation grounding system has been difficult, and the additional considerations are needed. UC substation was also difficult to design the grounding system because of so small substation area and high soil resistivity. This paper shows the examples of reducing the grounding system resistance reasonably by using several ways. Designing the ground grid electrode in the access road, deep electric earth probe, changing the substation soil with the law level resistivity soil. This report deals with the computer simulation of the grounding system resistance about the ways illustrated above.

  • PDF

The example of the Carbon Grounding Modules installation for PSD systems at a subway station, Seoulmetro (서울메트로 PSD장비 탄소접지모듈 설치 사례)

  • Chung, Young-Ki;Hyeon, Yong-Seop;Song, Byeong-Gwon;Kim, Yong-Hyeop
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.292-298
    • /
    • 2008
  • Seoul Metro and Seoul Metropolitan Rapid Transit Corp. have started installing screen doors at subway platforms to improve the environment of subways and prevent passengers' accidents since 2006. They are still installing screen doors at subway platforms and Metropolitan Rapid Transit Corporations in other areas are also proceeding with installment of screen doors or making preparations for it. Grounding is necessary for installing PSD systems. In case that PSD grounding is connected with existing electrical equipment grounding system, it was decided to install separate grounding for safe operation of PSD system and passenger safety. However, it's very difficult to install new grounding at the subway station compound. A way to improve this condition is that we proceed with grounding by composing grounding station by carbon grounding rod. This paper will mainly deal with how to design and construct carbon ground rod, which has been applied to PSD system grounding since 2006, including its experimental examples. In this paper, ways to secure ground resistance below 5 ohms, which is resistance necessary for PSD grounding, and to compose grounding system were also discussed. Furthermore, a ground test to check the ability to fulfill a role of PSD grounding system was conducted. As a result of applying carbon grounding module, PSD system is being operated without any problem and the installment of PSD system will be continuously expanded in the future. It's also thought that a way to integrate grounding of each functional room which has been installed at the subway station compound and to arrange equipotential grounding should be reviewed and performed promptly.

  • PDF

An Improved Method for Mesh Grounding System Using Spaced Arrangement of Grounding Conductor (접지도체의 간격배치에 따른 개선된 접지설비 모델)

  • Song, Young-Joo;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.57-65
    • /
    • 2005
  • No matter how well the equally spaced grounding grid is designed, there we questions keep rising, such as leakage of current from comer conductor, high voltage of touch voltage in comers of grid than in center, and high material cost for grounding grid. The best-fitted design for unequally spaced grounding grid is a part that must be considered. Explain advantages of unequally spaced grounding grid and lead formula by dividing the number of grid division, j, into 20, instead of 7. Then, present Dij, which is optimum rate for unequally spaced grounding grid and verify safety and economy of the unequally spaced grounding grid by computer simulation with a poly-nominal function form.

An Improved Method for Mesh Grounding System Using Unequally Spaced Arrangement (접지도체의 간격배치에 따른 개선된 접지설비 모델)

  • Choi, Hong-Kyoo;Song, Young-Joo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.259-265
    • /
    • 2004
  • No matter how well the equally spaced grounding grid is designed, there are questions keep rising, such as leakage of current from comer conductor, high voltage of touch voltage in corners of grid than in center, and high material cost for grounding grid. The best-fitted design for unequally spaced grounding grid is a part that must be considered. Explain advantages of unequally spaced grounding grid and lead formula by dividing the number of grid division, j, into 20, instead of 7. Then present $D_{ij}$, which is optimum rate for unequally spaced grounding grid and verify safety and economy of the unequally spaced grounding grid by computer simulation with a poly-nominal function form.

  • PDF